Examen

FLSD Non-fire component questions and answers

Note
-
Vendu
-
Pages
7
Grade
A+
Publié le
24-10-2025
Écrit en
2025/2026

two way communication capability 23 ) Elevators that will be used during a non fire emergency must contain which feature a ) Emergency Door release b ) two way communication capability c ) designated air supply d ) Phase 2 capability only if fire or smoke is present 24 ) Under what circumstances should a manual pull station be activated during a non fire emergency a ) The manual pull station should never be activated during a non fire emergency b ) only when it's activation will assist in building notification c ) only if fire or smoke is present d ) it can be activated any time the FLSD director determines is use is necessary

Montrer plus Lire moins
Établissement
FLSD
Cours
FLSD









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
FLSD
Cours
FLSD

Infos sur le Document

Publié le
24 octobre 2025
Nombre de pages
7
Écrit en
2025/2026
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

FLSD F89 questions and answers
When fumigating or insecticidal fogging is required, __________. ✔✔Written notice is
required at least 48 hours in advance to the FDNY, W97 certificate, entire building must
evacuate

The activation of the elevator lobby smoke detectors will cause the elevators to
_______. ✔✔Be recalled automatically to the designated landing.

In terms of standpipe and sprinkler systems, the FLSD must know all of the following,
EXCEPT the: ✔✔rate of galloons per minute supplied by the city mains

At least one FLS warden is required for ________ ✔✔Each floor of the building

The fire guard performing the fire watch must _________ ✔✔Have no other duties
during the fire watch

When there is a SIGNIFICANT drop in pressure within the standpipe system, which of
the the pumps would activate first ? ✔✔Auxiliary jockey pump

Select the INCORRECT statement regarding the fire command center. ✔✔...


it will be located near or part with the elevator control panel or in the building's main
lobby on the entrance floor, allowing firefighters easy access to manage elevator
operations during an emergency

Horns, strobes, and speakers are ______ ✔✔Alarm indicating devices

A fire guard should be available to patrol all areas in which the fire protection system is
out of service at least once every ✔✔hour

Control valves in standpipe systems require signs indicating the _________
✔✔Location of hose valves

Rooftop gardens or Landscaping of more than 250 square feet must be provided with a
______ ✔✔Garden hose

Assuming a FLSD is only holding an S13/S14 certificate of fitness, can he/she repair the
standpipe system? ✔✔No. Only inspections are allowed under that Certificate of fitness

, Cut natural trees are allowed to be displayed in ✔✔Outdoor spaces

The flsd must be present in an office building have an occupant load of ____ or more
persons, or more than _____ persons above and below street level. ✔✔100, 500

Air pressure in a(n) ________ allows forceful discharge of water into the sprinkler
system. ✔✔Pressure Tank

In areas exposed to freezing tempatures, which type of sprinkler system is commonly
found? ✔✔Dry pipe sprinkler system, as it is designed to prevent water from freezing in
the pipes

Select the fire pump on the photo below ✔✔II (Tool box looking part)

In which of the following situations would a person WITHOUT Certificate of Fitness be
allowed to perform fire watch during impairment ✔✔Under no Circumstances.3 type of
signals at panel ✔✔Supervisory and trouble

Central station company ✔✔A facility that receives alarm signals from a protected
premise and retransmits or otherwise reports such alarm signals to the FDNY.

F-01 ✔✔Impairments / something impaired with sprinklers, standpipe, or fire alarm.

F-02 ✔✔Specific to shelters

F-03 & F-04 ✔✔Places of public assembly

S-12 ✔✔Sprinklers

S-13 ✔✔Standpipes

S-95 ✔✔Specific to panels that do not require two way conversations

F-80 ✔✔Shelter coordinator

F-89 ✔✔FLSD. Buildings with more than 100 people, below or above ground level. Up
to 500 people at max.

Warden ✔✔Responsible for investigating, communicating through warden phone

Announcement set up ✔✔What, where, what & why

FLSD staff ✔✔Warden/floor warden, deputy, searchers, and brigades
€9,60
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur
Seller avatar
Gnurse

Faites connaissance avec le vendeur

Seller avatar
Gnurse NEWCASTLE UNIVERSITY
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
0
Membre depuis
1 année
Nombre de followers
0
Documents
213
Dernière vente
-

0,0

0 revues

5
0
4
0
3
0
2
0
1
0

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions