Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4.2 TrustPilot
logo-home
Examen

Massachusetts Oil burner Practice Questions and Answers (100% Correct Answers) Already Graded A+

Note
-
Vendu
-
Pages
5
Grade
A+
Publié le
21-10-2025
Écrit en
2025/2026

Massachusetts Oil burner Practice Questions and Answers (100% Correct Answers) Already Graded A+

Établissement
Massachusetts Oil Burner
Cours
Massachusetts Oil burner









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Massachusetts Oil burner
Cours
Massachusetts Oil burner

Infos sur le Document

Publié le
21 octobre 2025
Nombre de pages
5
Écrit en
2025/2026
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

1
For Expert help and assignment solutions, +254707240657


Massachusetts Oil burner Practice
Questions and Answers (100% Correct
Answers) Already Graded A+


The cross connection between two supply tanks shall not
exceed?— Ans: 660 gallons
When is an automatic draft control not required?— Ans: When
the equipment is designed to control the draft.
© 2025 Assignment Expert




Combustion performance testing can indicate:— Ans: Improper
air oil mixture, too much combustion air, and low pump pressure.
If a second oil-burning appliance is installed in a single chimney,
Guru01 - Stuvia




you must insure:— Ans: Sufficient draft is available for safe
operation of all connected equipment.
Delayed ignition can be caused by:— Ans: Weak ignition
transformer
You should replace the oil burner nozzle with:— Ans: The
manufacturers recommended nozzle spray pattern and spray
angle.
Viscosity problems can be corrected by:— Ans: Decreasing the
nozzle size and increasing the pump pressure accordingly
The minimum operating pressure of an oil pump is:— Ans: 100 PSI
If a stack relay fails you, must?— Ans: Replace it with an
approved type controller
Aquastats are normally found on what type of heating systems?—
Ans: Hydronic
Airstats are found on what type of heating systems?— Ans:
Forced warm air systems
Under sized returns on a warm air system can result in what?—
Ans: Short cycling of the oil burner

, 2
For Expert help and assignment solutions, +254707240657
Incorrect nozzle selection in regards to gallon per hour, can result
in what problems in a steam system?— Ans: Some radiators not
heating quickly enough
Low boiler water temperature in a hydronic hot water system may
be caused by?— Ans: Undersized oil burner nozzles
Delayed opening oil valves are used to?— Ans: Allow oil pump to
come up to speed
If a steam boiler is to be installed with an automatic feeder it must
also have:— Ans: A backflow prevention device
How can a damaged heat exchanger be detected on a forced
warm air system?— Ans: With a smoke trace candle
© 2025 Assignment Expert




If a high limit is installed to prevent high boiler water temperature,
what is the function of the low limit?— Ans: To maintain
temperature for domestic hot water
Guru01 - Stuvia




On a steam system, a plugged siphon loop can have what affect
on the heating system?— Ans: Insufficient heat in the living space
On a triple acting aquastat a minimum of 20 degrees is
recommend between the high and low limit, this will prevent?—
Ans: The boiler going off on high limit before reaching the
minimum circulator temperature
An advantage of flame retention burner is— Ans: Their high static
pressure enables boilers and furnaces with tighter more efficient
heat exchange passages
The key final adjustment for most oil burners is— Ans: Combustion
air
Dirt or lint buildup in the bevel of the burner fan blades will— Ans:
Reduce the amount of combustion air
To change the air ratio for different firing rates with an adjustable
head burner you— Ans: Adjust the position of the drawer
assembly in the Air tube
All petroleum products are chemical compounds of— Ans:
Hydrogen and carbon
€10,05
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Guru01 Chamberlain College Nursing
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
216
Membre depuis
1 année
Nombre de followers
32
Documents
20881
Dernière vente
1 semaine de cela

3,8

36 revues

5
15
4
8
3
7
2
1
1
5

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions