Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4.2 TrustPilot
logo-home
Examen

Backflow Prevention Assembly Tester — Full Practice Exam + Study Guide 2026 | Verified Questions & Answers | Guaranteed Pass

Note
-
Vendu
-
Pages
20
Grade
A+
Publié le
06-10-2025
Écrit en
2025/2026

Backflow Prevention Assembly Tester — Full Practice Exam + Study Guide 2026 | Verified Questions & Answers | Guaranteed Pass

Établissement
Backflow Prevention Assembly Tester
Cours
Backflow Prevention Assembly Tester










Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Backflow Prevention Assembly Tester
Cours
Backflow Prevention Assembly Tester

Infos sur le Document

Publié le
6 octobre 2025
Nombre de pages
20
Écrit en
2025/2026
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

Backflow Prevention Assembly Tester — Full Practice
Exam + Study Guide 2026 | Verified Questions & Answers
| Guaranteed Pass


What’s Included:

 100+ multiple-choice questions covering all device types (RP, DC, PVB, SVB) and
failure scenarios
 Verified answers with detailed explanations so you understand why answers are correct
 Comprehensive Study Guide, reviewing hydraulics, cross-connection control principles,
regulatory codes, test procedures, diagnostics, maintenance
 Updated 2024 content aligned with the latest standards (USC Manual, AWWA / ABPA
references)
 Tips, shortcuts & exam strategies to maximize your score
 Downloadable PDF + printable formats

Why choose this package?

 Contains realistic, exam-style questions (not just superficial ones)
 Designed by certified backflow testers and instructors
 Helps you identify weak areas and reinforce understanding
 Good for initial certification and recertification
 Supports multiple jurisdictions (with core theory that applies widely)




BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM

A mixture of air and gas is considered hazardous when the mixture exceeds what percentage of gthe
lower explosive limit

(A) 0%
(B) 3%
(C) 7%
(D) 10%

10%

To exert a pressure of 1.0 psi at base of a water column the column would have to be

(A) 4.34 high

,(B) 14.7 high
(C) 27.75 high
(D) 33.89 high

27.75 high

A DC must be tested

(A) Upon installation
(B) Every 6 month
(C) Annually on a health hazard
(D) none of the above

Upon installation

In responding to a backflow incident the water purveyor should

(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a good excuse

Implement the emergency response plan



An absolute perssure of 25 psiaa (at sea level) is equal to approximately

(A) 5 psi
(B) 10 psi
(C) 20 psi
(D) 25 psi

10 psi

Dueing a field test the air inlet on PVB must open at

(A) Above 2.0 psid
(B) Below 1.0 psid
(C) Above 1.0 psid
(D) Below 2.0 psid

Above 1.0 psid

A differential pressuer gauge is used to field test

(A) PVB's
(B) Dual Checks

, (C) AVB's
(D) All the above

PVB's

Backflow in a water supply can be caused by

(A) Backpressure only
(B) A Barometric Loop
(C) Backsiphonage only
(D) Backpressure and Backsiphonage

Backpressure and Backsiphonage

A BPAT tester is required to report test information on the proper forms to the

(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above

Administrative authority

The relief valve opens when closing #2 shut off valve on a RP What is the most probable cause

(A) #1 Shut off valve is open
(B) #2 Shut off valve is open
(C) #1 check is fouled open
(D) Shut off is leaking

#1 check is fouled open

When field testing the #1 Check of a RP the differential pressurw shouid be

(A) Greter than or equal to 5.0 psid
(B) 3.0 psid greater than the relief valve opening point
(C) 1.0 psid in the directiom of flow
(D) Less than 5.0 psid

Greter than or equal to 5.0 psid

When testing a SVB what is the firsrt test being performed

(A) The air inlet opening point
(B) The static pressure across the check valve
(C) To verify the #2shut off hold tight
(D) To check if the SVB hold water

The static pressure across the check valve
€19,89
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
studyguidepro NURSING
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
30
Membre depuis
2 mois
Nombre de followers
2
Documents
1064
Dernière vente
1 jours de cela
verified exams

Updated exams .Actual tests 100% verified.ATI,NURSING,PMHNP,TNCC,USMLE,ACLS,WGU AND ALL EXAMS guaranteed success.Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied. **Ace Your Exams with Confidence!**

3,0

4 revues

5
2
4
0
3
0
2
0
1
2

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions