Chapter 91 - Oil Burners for Heating Boilers Questions and Answers correct d *Maximum static pressure in a fuel oil line before the oil pump is limited by code to approximately: A 10 kPa B 15 kPa C 80 kPa D 35 kPa E 70 kPa a Which of the following is NOT a type of oil burner? A Atmospheric burners B Steam atomizing burners C Mechanical or pressure atomizing burners D Centrifugal or rotary cup burners E Air atomizing burners b A modulating pressure atomizer has its return oil flow regulated by: A A modulating valve to the burner B A modulating valve in the return line C A solenoid valve in the return line D A pressure regulator E Pump speed b A time delay oil valve: A Opens when the oil pump starts B Opens 5 to 15 seconds after ignition begins. C Opens on flame failure D Is located on the return line E Is upstream of the pressure regulating valve c Regulations require that the minimum distance between an oil-fired furnace and an indoor oil storage tank must be: A 7 m B 5.2 m C 2.1 m D 4.7 m E 9.8 m e An air atomizing burner utilizes an air pressure of approximately: A 15 kPa B 150 kPa C 75 kPa D 95 kPa E 100 kPa a To which of the following oil burners is the oil supplied under high pressure? A Mechanical atomizing burner B Air atomizing burner C Rotary cup burner D Steam atomizing burner E Multi-spud burner b Before being pumped to the burner, heavy oils are heated to approximately: A 203°C B 95°C C 115°C D 75°C E 150°C d A multi-burner cluster has secondary and tertiary nozzles ignited by: A An igniter spark B An intermittent pilot flame C An interrupted pilot D The primary burner E A continuous pilot e Intermediate and high fire burner nozzles have higher capacities than the primary burner nozzle: A To give greater firing variations B To prevent pressure surges C To prevent ignition puff-backs D Because of the pump being of the positive displacement type E To allow slower boiler warm-ups b When a greater than normal amount of combustible mixture is ignited, the result may be: A A boiler explosion B A puff-back C A negative furnace pressure D A too rapid boiler warm-up E Liquid fuel entering the furnace c To prevent the possibility of a furnace explosion, it is important that the furnace is _____ before the igniter is energized and fuel is supplied to the burner nozzle(s). A Pre-heated B Post-heated C Purged D Cooled E Pressurized b The two basic varieties of mechanical atomizing oil burners are the: A Variable capacity and modulating burners B Constant and variable capacity burners C Modulating and cluster burners D Rotary and reciprocating cup burners E light oil and heavy oil burners b The compressed air used as atomizing air in the air atomizing oil burner is also called: A Secondary air B Primary air C Pre-mixed air D Combustion air E Post-compressed air d The pressure range for pressure-atomizing burners fired with light fuel oil is approximately: A 50 to 100 kPa B 150 to 250 kPa C 300 to 550 kPa D 550 to 700 kPa E 700 to 850 kPa e The design capacity of a constant capacity mechanical atomizer is a function of: A Orifice size B Pump speed C Pump size D Supply pressure E Oil viscosity c When using mechanical fuel oil atomization: A 70 kPa steam pressure is required at the burner B Dry saturated steam or superheated steam should be used C High pump pressure is required D Steam pressure is required to keep the bypass open E 35 to 40 kPa oil pressure is required d An atomizing air compressor is usually: A A variable displacement type B A centrifugal type C An axial type D A small, rotary air compressor E A regenerative type d The reducing of oil into very small particles is termed A fluidization B fractionation C turbulence D atomization E distillation a Oil burners can be divided into three classes: 1. air and steam atomizing burners 2. mechanical or pressure atomizing burners 3. centrifugal or rotary cup burners 4. atmospherical pressure burners 5. gravitational pressure burners A 1, 2, and 3 B 1, 2, and 4 C 2, 3, and 4 D 3, 4, and 5 E 2, 3, and 5 b A relief valve is placed on the discharge of a fuel oil pump A because the pump is a dynamic type B so burner design pressure is not exceeded C so burner capacity is maintained D to prevent pump rupture E to prevent over-firing of the boiler b A time delay oil valve A opens when the pump starts B opens once ignition is verified C opens on flame failure D is located on the return line E is upstream of the pressure regulating valve d An air atomizing compressor is usually A a variable displacement type B a centrifugal type C an axial type D a positive displacement type E a regenerative type c A modulating capacity mechanical atomizing oil burner is also called an? A Constant capacity B Steam atomized C Wide range atomizer D Centrifugal Cup b The purpose of pressure relief valve on a constant capacity fuel supply is to: A Relieve the pressure from the oil line any discharge it to atmosphere B Re-direct fuel oil that above the set pressure back to the tank or strainer C Protect the oil tank from rupturing D All the above a The purpose of a cut off valve is to: A Prevents too low of an oil pressure to supply the burner B Cut off the burner is to high C Relieve the pressure of the fuel in an over-pressure situation D None of the above

Montrer plus Lire moins
Établissement
MASSACHUSETTS OIL BURNER
Cours
MASSACHUSETTS OIL BURNER









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
MASSACHUSETTS OIL BURNER
Cours
MASSACHUSETTS OIL BURNER

Infos sur le Document

Publié le
27 août 2025
Nombre de pages
5
Écrit en
2025/2026
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

Chapter 91 - Oil Burners for Heating
Boilers Questions and Answers correct

d - answer*Maximum static pressure in a fuel oil line before the oil pump is limited by
code to approximately:

*A* 10 kPa
*B* 15 kPa
*C* 80 kPa
*D* 35 kPa
*E* 70 kPa

a - answerWhich of the following is NOT a type of oil burner?

*A* Atmospheric burners
*B* Steam atomizing burners
*C* Mechanical or pressure atomizing burners
*D* Centrifugal or rotary cup burners
*E* Air atomizing burners

b - answerA modulating pressure atomizer has its return oil flow regulated by:

*A* A modulating valve to the burner
*B* A modulating valve in the return line
*C* A solenoid valve in the return line
*D* A pressure regulator
*E* Pump speed

b - answerA time delay oil valve:

*A* Opens when the oil pump starts
*B* Opens 5 to 15 seconds after ignition begins.
*C* Opens on flame failure
*D* Is located on the return line
*E* Is upstream of the pressure regulating valve

c - answerRegulations require that the minimum distance between an oil-fired furnace
and an indoor oil storage tank must be:

*A* 7 m
*B* 5.2 m
*C* 2.1 m
*D* 4.7 m

, *E* 9.8 m

e - answerAn air atomizing burner utilizes an air pressure of approximately:

*A* 15 kPa
*B* 150 kPa
*C* 75 kPa
*D* 95 kPa
*E* 100 kPa

a - answerTo which of the following oil burners is the oil supplied under high pressure?

*A* Mechanical atomizing burner
*B* Air atomizing burner
*C* Rotary cup burner
*D* Steam atomizing burner
*E* Multi-spud burner

b - answerBefore being pumped to the burner, heavy oils are heated to approximately:

*A* 203°C
*B* 95°C
*C* 115°C
*D* 75°C
*E* 150°C

d - answerA multi-burner cluster has secondary and tertiary nozzles ignited by:

*A* An igniter spark
*B* An intermittent pilot flame
*C* An interrupted pilot
*D* The primary burner
*E* A continuous pilot

e - answerIntermediate and high fire burner nozzles have higher capacities than the
primary burner nozzle:

*A* To give greater firing variations
*B* To prevent pressure surges
*C* To prevent ignition puff-backs
*D* Because of the pump being of the positive displacement type
*E* To allow slower boiler warm-ups

b - answerWhen a greater than normal amount of combustible mixture is ignited, the
result may be:

*A* A boiler explosion
€14,42
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Pogba119 Harvard University
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
48
Membre depuis
1 année
Nombre de followers
2
Documents
4946
Dernière vente
1 mois de cela
NURSING TEST

BEST EDUCATIONAL RESOURCES FOR STUDENTS

3,9

9 revues

5
4
4
2
3
2
2
0
1
1

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions