NEC 2017 JOURNEYMAN STUDY GUIDE EXAM QUESTION WITH ANSWERS 2025/2026 GRADED A+ Service drop conductors shall maintain _____ clearance from the sides and bottoms of operable windows. - 3', 225.19(D)(1),230.9(A) Overhead service drop conductors shall not be smaller than _____ away copper wire. - 8, 230.23(B) According to the NEC, service drop conductors (600v or less) must be _____ above finish grade. - 10',230.24(B)(1) What is the overhead clearance for service conductors 600 volts and less going over a residential property? - 12', 230.24(B)(2) Service entrance cables shall be supported by approached means within ____ ft of every service head and at intervals not exceeding _____ ft. - 12", 30", 230.51(A) Cable limiters are not permitted to be connected to the supply side of the service disconnecting means. T/F - False, 230.82(1) What is the maximum size fuse that can be installed for a #18 fixture wire and be considered protected? - 20, 240.5(B)(2)

Montrer plus Lire moins
Établissement
NEC
Cours
NEC









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
NEC
Cours
NEC

Infos sur le Document

Publié le
23 février 2025
Nombre de pages
7
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

NEC 2017 JOURNEYMAN STUDY GUIDE EXAM QUESTION
WITH ANSWERS 2025/2026 GRADED A+
Service drop conductors shall maintain _____ clearance from the sides and bottoms of
operable windows. - 3', 225.19(D)(1),230.9(A)

Overhead service drop conductors shall not be smaller than _____ away copper wire. -
8, 230.23(B)

According to the NEC, service drop conductors (600v or less) must be _____ above
finish grade. - 10',230.24(B)(1)

What is the overhead clearance for service conductors 600 volts and less going over a
residential property? - 12', 230.24(B)(2)

Service entrance cables shall be supported by approached means within ____ ft of
every service head and at intervals not exceeding _____ ft. - 12", 30", 230.51(A)

Cable limiters are not permitted to be connected to the supply side of the service
disconnecting means. T/F - False, 230.82(1)

What is the maximum size fuse that can be installed for a #18 fixture wire and be
considered protected? - 20, 240.5(B)(2)

Type S adapters shall be designed so that once inserted in a fuse holder, they ____. -
Cannot be removed, 240.54(C)

What is the minimum spacing between grounding electrodes? - 6', 250.53(B)

In a building where a metal underground water line is available, the maximum size of
the grounding electrode conductor for an ungrounded system with 3/0 copper service
conductors shall be? - #4 AWG copper, 250.66

Interior metal water piping located not more than ____ from the point of entrance to a
building shall be permitted to be used as a conductor to interconnect electrodes that are
part of the grounding system. - 5', 250.68(C)

What is the minimum size grounded conductor permitted to be installed when the
ungrounded conductors are size 1/0 copper? - #6 AWG copper, Table 250.102(C)(1)

A conductor intended solely for the purposes of grounding shall be either bare or color
coded ______ or _______. - Green, Green with a yellow stripe, 250.119

Where metal fences are located within ____ft of the electrical conductors or equipment,
the fence shall be bonded. - 16', 250.194(A)

, Underground service conductors not encased in concrete shall be identified by a
warning ribbon _____ inches above the underground installation. - 12", 300.4(D)(3)

Where raceways contain ____ AWG or larger insulated conductors that enter a box the
conductors shall be protected by a bushing. - 4AWG, 300.4(G)

Residential direct burial branch circuits rated 120V or less with GFCI protection and a
maximum over current protection of 20A shall have a minimum cover requirement of __
inches. - 12, Table 300.5

Direct buried service conductors, 1000V and less, shall have a minimum cover of ___
inches of dirt. - 24", Table 300.5

The free length of conductors at each outlet and switch point for connecting to devices
is ___ inches. - 6", 300.14

Four #10 THHN, copper, current carrying conductors are installed in the same EMT in a
e being temperature of 30*C. the allowable ampacity of each of the conductors is ___
amps. - 32, Table 310.15(B)(3)(a), Table 310.15(B)(16)

For a 150a dwelling unit service what is the demand factor? - 83% 310.15(B)(7)

The capacity of a #10 TW not more than 3 wires when installed on a conduit or cable is
___ amps. - 30, Table 310.15(B)(16)

What is the amperage rating of a #2 FEPB cable? - 293A, 310.15(B)(19)

What is the wire size range for type XHH cable with 45 mil insulation? - 8-2AWG, Table
310.104(A)

Conductors ____ and larger must be stranded. - 8AWG, 310.106(C)

Size approved drainage openings shall be permitted to be installed in conduit bodies
used in wet locations. - Not larger than 1/4", 314.15

What trade size round/octagonal box has a minimum of 21.5in^2? - 4 x 2 1/8" round ,
octagonal, Table 314.16(A)

What is the minimum volume of a box trade size (4x 2 1/8 x 1 1/2) - 10.3"^3, Table
314.16(A)

What is the volume allowance for #18AWG conductor? - 1.5 in^3, Table 314.16(B)

When determining the numbers of wires in a box for box fill, a conductor passing
through the box without a splice or tap with a conductor loop less than 12" is counted as
___. - One volume allowance, 314.16(B)(1)
€9,29
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
BOARDWALK Havard School
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
181
Membre depuis
1 année
Nombre de followers
6
Documents
24136
Dernière vente
18 heures de cela
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3,7

33 revues

5
14
4
6
3
7
2
0
1
6

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions