Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4,6 TrustPilot
logo-home
Examen

ACI Certification Test. All Revision Questions and Correct Answers (Already Graded A+) (2024 Update) 100% Guarantee

Note
-
Vendu
-
Pages
17
Grade
A+
Publié le
05-02-2025
Écrit en
2024/2025

ACI Certification Test. All Revision Questions and Correct Answers (Already Graded A+) (2024 Update) 100% Guarantee

Établissement
ACI Certification
Cours
ACI Certification










Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
ACI Certification
Cours
ACI Certification

Infos sur le Document

Publié le
5 février 2025
Nombre de pages
17
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

ACI Certification Test. All Revision Questions and Correct Answers (Already Graded A+)
(2024 Update) 100% Guarantee




C1064/C1064M - ANSWER- Standard test method for temperature for concrete



C172/C172M - ANSWER- Standard practice for sampling concrete



C143/C143M - ANSWER- Standard testing for Slump



C138/C138M - ANSWER- Standard test method for Density (unit weight), yield, and air
content (Gravimetric)


C231/C231M - ANSWER- Standard test method for Air Content (Pressure Method)



C173/C173M - ANSWER- Standard test method for Air Content (Volumetric Method)



C31/C31M - ANSWER- Stand Practice for making and curing conrete test specimens in field


C1064/C1064M
The end of hte temperature sensing portion of hte temperature measuring device is submerged a
minimum of _______ or _______" into the freshly mixed concrete - ANSWER- 75mm or 3"


C1064/C1064M
The Temperature measuring device shall be capable of accurately measuring hte temperature of
Freshly mixed concrete to _________ throughout a range of _________ - ANSWER- 0.5
degree C (1 degree F) and 50 degree C (30fF - 120F)


C1064/C1064M

,The temperature measuring device shall be verified___________, or whenever there is a question
of___________ - ANSWER- Annually or Accuracy


C1064/C1064M

The temperature of concrete may be measured in a wheelbarrow T/F? - ANSWER- True


C1064/C1064M

The temperature of concrete may be measured in a wall form T/F - ANSWER- True


C1064/C1064M
A composite sample of concrete is required EVEN if the only purpose for obtaining hte sample is
to determine the temperature T/F - ANSWER- False


C1064/C1064M

What must be done to the sample container prior to sampling hte concrete - ANSWER-
Dampened (With Water)


C1064/C1064M
What must be done to the concrete surrounding the temperature masuring device after the device
is submerged in the fresh concrete? - ANSWER- Gently press the concrete around the
temperature masuring device at the surface of the concrete


C1064/C1064M
How long must the temperature measuring device remain in the freshly mixed concrete? -
ANSWER- 2 min, no more than 5 min


C1064/C1064M

After the temperature of the concrete is read, what is then required - ANSWER- Recording the
Temperature

, C1064/C1064M

The temperature of the concrete is reported to the nearest - ANSWER- 0.5 degree C (1 degree
F)


C1064/C1064M
According to the test method C1064/C1064M, what is one reason to take the temperature of the
concrete - ANSWER- Verify conformance to specified requirement for temperature of concrete


C1064/C1064M
A maximum temperature of Freshly mixed concrete is specified in Test method of C1064/C1064M
- ANSWER- FALSE, its in the spec from the owner


C1064/C1064M
The sample of concrete used for temperature determination must be rodded 25 times T/F -
ANSWER- FALSE


C172/C172M
Sampling by this practice covers procedures for obtaining representative samples, on which test
are to be performed to determine______________ with quality requirements of the specifications
under which concrete is furnished - ANSWER- Compliance


C172/C172M
This practice covers sampling from five types of equipment, which are ___________,
______________, ___________,_____________, and ____________ - ANSWER- Stationary
mixers, paving mixers, revolving drum mixers, continous mixers, and open top mixers


C172/C172M
The elapsed time between obtaining the first and final portion of a composite sample shall not
exceed ________- - ANSWER- 15 minutes


C172/C172M
€7,53
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
LECTpharis California University Of Pennsylvania
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
29
Membre depuis
2 année
Nombre de followers
2
Documents
4264
Dernière vente
1 mois de cela
The Valedictorians' Hub

Get well-researched exam revision papers with correct answers for A+ grades.

5,0

5 revues

5
5
4
0
3
0
2
0
1
0

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions