Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4.2 TrustPilot
logo-home
Examen

Mass oil burner / NFPA 31 & NORA Exam Questions and Answers 100% Pass

Note
-
Vendu
-
Pages
16
Grade
A+
Publié le
23-12-2024
Écrit en
2024/2025

Mass oil burner / NFPA 31 & NORA Exam Questions and Answers 100% Pass Cast iron fittings can be used in heating fuel systems? - False Tank vent shall terminate - Within 12 feet of the fill and visible from the fill Tanks exceeding 330 gallons must have - Top supply connection Fuel return piping from an appliance shall - Enter the top of the tank Oil appliances burning used oil shall only be installed - In commercial or industrial occupancies Technician must be present for filling of new oil tank - False A common tank vent pipe shall be - One pipe size larger than the largest individual vent pipe connected to it If oil supply piping is not visible for inspection you must - Pressure or vacuum test the line Installation instructions for the care and operation of the appliance must be posted - True Oil burning appliances shall have - Limit control for pressure in steam, temperature in water boiler, and temperature in furnace Above ground tank installed inside must be pitched - Torwards the supply at a pitch of 1/4 inch per foot Outdoor tanks must be located - Five feet from property line for 275g or smaller, ten feet for more than 275 but not exceeding 660g. Must be on concrete slab 2 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE A chimney connector shall maintain a pitch or rise of - 1/4 inch per foot Minimal gauge thickness for steel flue pipe connectors less than nine inches in diameter - 26 gauge Oil fired water heater must be equipped with water temp, pressure, and vacuum relief device - True Tank vent piping shall be - Pitched forward tank, terminate two feet minimum from building openings, corrosion resistant weatherproof cap Direct vent systems shall terminate - 4 feet horizontally from a building opening Fuel can be transferred from tank to appliance by pressurizing the tank - False Fusible link safety shutoff valves shall be located - Within six inches of the filter between the tank and filter Before installation of new oil burner you are required to - Inspect the combustion chamber A crankcase oil burner can be installed in any location where a standard oil burner was located - False Can tanks be installed in garages - Yes, if protected from vehicle impacts by barriers Teflon tape can be used on oil lines - False The trial for ignition period for oil burners less than 20 GPM is? - 15 seconds Fusible switches shall operate at a temp of - 165F A masonry chimney needs a metal liner - False Any valves used on oil burner installation must be a - Fusible valve What form is used to pull an oil burner permit - Form 1 What size pipe is used to cross connect tank outlet piping - 1/2 inch 3 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE What is an oil safety valve required - On existing installations when a burner, boiler, furnace or tank is replaced When must you install a draft regulator - When not exempted by the manufacturer As of January 1 2014, max safety timing for an oil burner safety switch must be no more than - 15 seconds What type of boiler must be equipped with low water cut off - Water boilers over 400,000 BTU, all steam boiler What device must be equipped with air proving switch - A draft inducer New burner controls must be - Interrupted ignition Hot water boilers need low water cut off if over - 500,000 BTU How far must continuous concrete slab extend beyond tank perimeter - 8 inches Can I use any form other than form 1 or form 1A - No, only form 1 and 1A are approved by state fire Marshall What must I do if I have a oil tank larger than 10,000 gallons - You must apply for, and obtain both a permit and license from the local town or city for the use of the tank What license are acceptable for installing an oil burner or oil tank - M.G.L c. 148, & 10D, and applicable provisions of St. 1964, C. 680 allows for only the holder of certific

Montrer plus Lire moins
Établissement
Oil Burners
Cours
Oil Burners










Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Oil Burners
Cours
Oil Burners

Infos sur le Document

Publié le
23 décembre 2024
Nombre de pages
16
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

1|Page




Mass oil burner / NFPA 31 & NORA Exam
Questions and Answers 100% Pass

Cast iron fittings can be used in heating fuel systems? - ✔✔False


Tank vent shall terminate - ✔✔Within 12 feet of the fill and visible from the fill


Tanks exceeding 330 gallons must have - ✔✔Top supply connection


Fuel return piping from an appliance shall - ✔✔Enter the top of the tank


Oil appliances burning used oil shall only be installed - ✔✔In commercial or industrial occupancies


Technician must be present for filling of new oil tank - ✔✔False


A common tank vent pipe shall be - ✔✔One pipe size larger than the largest individual vent pipe

connected to it


If oil supply piping is not visible for inspection you must - ✔✔Pressure or vacuum test the line


Installation instructions for the care and operation of the appliance must be posted - ✔✔True


Oil burning appliances shall have - ✔✔Limit control for pressure in steam, temperature in water boiler,

and temperature in furnace


Above ground tank installed inside must be pitched - ✔✔Torwards the supply at a pitch of 1/4 inch per

foot


Outdoor tanks must be located - ✔✔Five feet from property line for 275g or smaller, ten feet for more

than 275 but not exceeding 660g. Must be on concrete slab




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

,2|Page


A chimney connector shall maintain a pitch or rise of - ✔✔1/4 inch per foot


Minimal gauge thickness for steel flue pipe connectors less than nine inches in diameter - ✔✔26 gauge


Oil fired water heater must be equipped with water temp, pressure, and vacuum relief device - ✔✔True


Tank vent piping shall be - ✔✔Pitched forward tank, terminate two feet minimum from building

openings, corrosion resistant weatherproof cap


Direct vent systems shall terminate - ✔✔4 feet horizontally from a building opening


Fuel can be transferred from tank to appliance by pressurizing the tank - ✔✔False


Fusible link safety shutoff valves shall be located - ✔✔Within six inches of the filter between the tank and

filter


Before installation of new oil burner you are required to - ✔✔Inspect the combustion chamber


A crankcase oil burner can be installed in any location where a standard oil burner was located - ✔✔False


Can tanks be installed in garages - ✔✔Yes, if protected from vehicle impacts by barriers


Teflon tape can be used on oil lines - ✔✔False


The trial for ignition period for oil burners less than 20 GPM is? - ✔✔15 seconds


Fusible switches shall operate at a temp of - ✔✔165F


A masonry chimney needs a metal liner - ✔✔False


Any valves used on oil burner installation must be a - ✔✔Fusible valve


What form is used to pull an oil burner permit - ✔✔Form 1


What size pipe is used to cross connect tank outlet piping - ✔✔1/2 inch




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

, 3|Page


What is an oil safety valve required - ✔✔On existing installations when a burner, boiler, furnace or tank

is replaced


When must you install a draft regulator - ✔✔When not exempted by the manufacturer


As of January 1 2014, max safety timing for an oil burner safety switch must be no more than - ✔✔15

seconds


What type of boiler must be equipped with low water cut off - ✔✔Water boilers over 400,000 BTU, all

steam boiler


What device must be equipped with air proving switch - ✔✔A draft inducer


New burner controls must be - ✔✔Interrupted ignition


Hot water boilers need low water cut off if over - ✔✔500,000 BTU


How far must continuous concrete slab extend beyond tank perimeter - ✔✔8 inches


Can I use any form other than form 1 or form 1A - ✔✔No, only form 1 and 1A are approved by state fire

Marshall


What must I do if I have a oil tank larger than 10,000 gallons - ✔✔You must apply for, and obtain both a

permit and license from the local town or city for the use of the tank


What license are acceptable for installing an oil burner or oil tank - ✔✔M.G.L c. 148, & 10D, and

applicable provisions of St. 1964, C. 680 allows for only the holder of certificate of competency to install

oil burner equipment and sign form 1A


Do I need to pull a permit when replacing an oil line or installing an osv - ✔✔Yes. Any alteration of oil

burner install requires a permit be pulled under CMR 1.00 using form 1 only




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE
€10,96
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
KatelynWhitman West Virginia University
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
1089
Membre depuis
2 année
Nombre de followers
482
Documents
33020
Dernière vente
7 heures de cela
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3,6

238 revues

5
95
4
38
3
54
2
20
1
31

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions