Chapter 36 Fluoroscopy Practice Exam Questions and Answers- Updated 2024 T/F: A fluoroscopic exposure cannot be made until the carriage is returned to the full beam intercept position. - Answer-True T/F: Fluoroscopic x-ray tubes are designed to operate for longer periods of time at much lower mA, as compared to a typical diagnostic tube. - Answer-True T/F: The anode of the image intensification system is positioned outside the glass envelope, immediately in front of the output screen. - Answer-False T/F: Flux gain is a measurement of the increase in light photons caused by conversion efficiency of the output screen - Answer-True T/F: Brightness gain deteriorates with use. - Answer-True T/F: Most automatic brightness control systems monitor the current between the cathode and the anode of the image intensifier to maintain fluoroscopic image density and contrast. - Answer-True T/F: Most automatic brightness control systems have a relatively fast response time. - Answer-False EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 2/29 T/F: Quantum mottle is blotchy or grainy appearance caused by excessive radiation to create a uniform image. - Answer-False T/F: A video monitor is an anode ray tube. - Answer-False T/F: Video monitors can emit low energy x-rays. - Answer-True T/F: The tabletop exposure rate should not exceed 10 R/min. - Answer-false T/F: The minimum source-to-skin distance is 15" for stationary fluoroscopic equipment. - Answer-True T/F: The minimum source-to-skin distance is 12" for mobile fluoroscopic equipment. - Answer-True T/F: Magnification image intensifiers caused decreased patient dose. - Answer-False T/F: The highest energy scatter from the patient during fluoroscopy occurs at a 45-degree angle from the incident beam. - Answer-False Fluoroscopy is a ____________radiographic examination. a. dynamic b. static c. diagnostic d. more than one of the above - Answer-d. more than one of the above Fluoroscopy is the domain of the ______________. EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 3/29 a. radiographer b. radiologist c. radiation physicist d. radiography student - Answer-b. radiologist Fluoroscopy is commonly used for observation of ______________. a. the heart b. a surgical procedure c. the GI tract d. all of the above - Answer-d. all of the above The fluoroscopic x-ray tube and image receptor are mounted on a ___________________. a. carriage b. c-arm c. platform d. camera - Answer-b. c-arm The carriage commonly supports the _______. a, image intensifier b. power drive controls EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 4/29 c. spot film selector d. all of the above - Answer-d. all of the above Fluoroscopic mA range is commonly ___________ mA. a. 0.5 to 5.0 mA b. 5.0 to 10.0 mA c. 10.0 to 100 mA d. 100 to 500 mA - Answer-a. 0.5 to 5.0 mA During fluoroscopy, the SOD cannot be less than ________ inches. a. 12 b. 15 c. 20 d. 40 - Answer-b. 15 During fluoroscopic image intensification, the primary x-ray beam exits the patient and strikes the ________ of the image intensifier. a. input screen b. electrostatic lenses c. photocathode EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 5/29 d. output screen - Answer-a. input screen The input screen absorbs _____________ and emits __________. a. x-ray photons, light photons b. x-ray photons, electrons c. light photons, x-ray photons d. electrons, x-ray photons - Answer-a. x-ray photons, light photons The photocathode absorbs ____________ and emits ____________. a. x-ray photons, light photons b. x-ray photons, electrons c. light photons, x-ray photons d. electrons, x-ray photons - Answer-b. x-ray photons, electrons Electrostatic lenses are used to accelerate and focus ___________. a. light photons b. x-ray photons c. electrons d. none of the above - Answer-c. electrons The primary ___________ occurs from the acceleration and focusing of the electron beam. EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024 Page 6/29 a. phosphorescence b. magnification c. magnification d. brightness gain - Answer-d. brightness gain the output screen absorbs ____________ and emits ______________. a. electrons, light photons b. electrons, x-ray photons c. light photons, electrons d. light photons, x-ray photons - Answer-a. electrons, light photons The input screen is ___________ in shap

Montrer plus Lire moins
Établissement
Fluoroscopy
Cours
Fluoroscopy










Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Fluoroscopy
Cours
Fluoroscopy

Infos sur le Document

Publié le
16 octobre 2024
Nombre de pages
29
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024




Chapter 36 Fluoroscopy Practice Exam
Questions and Answers- Updated 2024

T/F: A fluoroscopic exposure cannot be made until the carriage is returned to the full beam

intercept position. - Answer✔✔-True


T/F: Fluoroscopic x-ray tubes are designed to operate for longer periods of time at much lower

mA, as compared to a typical diagnostic tube. - Answer✔✔-True


T/F: The anode of the image intensification system is positioned outside the glass envelope,

immediately in front of the output screen. - Answer✔✔-False


T/F: Flux gain is a measurement of the increase in light photons caused by conversion efficiency

of the output screen - Answer✔✔-True


T/F: Brightness gain deteriorates with use. - Answer✔✔-True


T/F: Most automatic brightness control systems monitor the current between the cathode and

the anode of the image intensifier to maintain fluoroscopic image density and contrast. -

Answer✔✔-True


T/F: Most automatic brightness control systems have a relatively fast response time. -

Answer✔✔-False




Page 1/29

,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


T/F: Quantum mottle is blotchy or grainy appearance caused by excessive radiation to create a

uniform image. - Answer✔✔-False


T/F: A video monitor is an anode ray tube. - Answer✔✔-False


T/F: Video monitors can emit low energy x-rays. - Answer✔✔-True


T/F: The tabletop exposure rate should not exceed 10 R/min. - Answer✔✔-false


T/F: The minimum source-to-skin distance is 15" for stationary fluoroscopic equipment. -

Answer✔✔-True


T/F: The minimum source-to-skin distance is 12" for mobile fluoroscopic equipment. -

Answer✔✔-True


T/F: Magnification image intensifiers caused decreased patient dose. - Answer✔✔-False


T/F: The highest energy scatter from the patient during fluoroscopy occurs at a 45-degree angle

from the incident beam. - Answer✔✔-False


Fluoroscopy is a ____________radiographic examination.


a. dynamic


b. static


c. diagnostic


d. more than one of the above - Answer✔✔-d. more than one of the above


Fluoroscopy is the domain of the ______________.

Page 2/29

, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024


a. radiographer


b. radiologist


c. radiation physicist


d. radiography student - Answer✔✔-b. radiologist


Fluoroscopy is commonly used for observation of ______________.


a. the heart


b. a surgical procedure


c. the GI tract


d. all of the above - Answer✔✔-d. all of the above


The fluoroscopic x-ray tube and image receptor are mounted on a ___________________.


a. carriage


b. c-arm


c. platform


d. camera - Answer✔✔-b. c-arm


The carriage commonly supports the _______.


a, image intensifier


b. power drive controls



Page 3/29
€10,93
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Emillect West Virginia University
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
28
Membre depuis
1 année
Nombre de followers
2
Documents
3004
Dernière vente
1 mois de cela
GOLDEN ORCHIDS STORE.

On this page, you find all documents, package deals, and flashcards offered by seller Emillect.

3,0

4 revues

5
1
4
0
3
2
2
0
1
1

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions