What is the difference between pumping in the parallel position and the
series position? (P.301) Correct Answer-When the pump transfer valve
is in the volume position, each of the impellers takes water from a
source and delivers it to the discharge.
Setting the transfer valve to series (pressure) greatly increases the
maximum pressure that may be attained. Increasing the pressure results
in a corresponding loss in volume.
Switching from volume to pressure can result in the immediate doubling
of the previous discharge pressure. This change may result in damage to
the pump and hoselines as well as injury to firefighters.
If there is any question as to the correct position for the transfer valve, it
is best to operate in parallel (volume) rather than series (pressure).
What are the common requirements for fire department pumpers? (P.14)
Correct Answer-Minimum pump capacity of 750 gpm and a water tank
with a capacity of at least 300 gallons.
What are some characteristics of initial attack fire apparatus? (P.16)
Correct Answer-Scaled-down versions of full-size pumpers, which are
called initial attack fire apparatus, mini-pumper/midi-pumper. Highly
maneuverable apparatus are often used to respond to incidents where
access is limited.
,What are the 2 basic functions of mobile water supply apparatus on the
fire ground? (P.18) Correct Answer-1. Mobile Water Shuttle
2. Stationary Reservoir or "Nurse tender"
What are some types of specialty fire apparatus and their uses? (P.19-22)
Correct Answer-Wildland fire apparatus
Aircraft rescue and fire fighting apparatus
Fireboats
Aerial apparatus equipped with fire pumps
Rescue apparatus equipped with fire pumps
Trailer-mounted fire pumps.
What are the 2 types of electric power generators used in emergency
service operations? (P.23) Correct Answer-Inverter
Generator
What should systematic maintenance procedures specify? (P.30) Correct
Answer-These procedures should specify maintenance procedures, when
they are performed, and who is responsible for conducting the
maintenance. The procedures should also specify a method for reporting,
correcting, and documenting all activities. The
What are the functions of apparatus maintenance and inspection records?
(P.31-32) Correct Answer-- In a warranty claim, these records may be
needed to document that required maintenance was performed.
, - In the event of an accident, maintenance records are among those likely
to be scrutinized by investigators.
- A completely documented history of recurrent repairs may also assist
in deciding whether to purchase a new apparatus as opposed to
continuing to repair an older vehicle
Why is inspection of apparatus easier if the apparatus is clean? (P.32)
Correct Answer-- Helps promote a longer vehicle life
- Inspection of apparatus and equipment components is easier when
parts are free of dirt and grime
When approaching a vehicle to be inspected, what should
driver/operators observe? (P.37) Correct Answer-- Any problems that
may be readily apparent from a distance.
- The terrain on which the vehicle is parking.
- Vehicle fluid leaks.
Why should fire pumps be tested at regularly scheduled intervals? (P.48)
Correct Answer-To compare actual performance to specific standards.
What abilities and skills are necessary for all driver/operators? (P.80)
Correct Answer-Reading skills
Computer skills
Writing skills
Math skills
Physical fitness