An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed defrost is based on time/temperature. The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the; - ans-Outdoor ambient thermostat The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the; - ans-Initial balance point At what temperature is an outdoor ambient thermostat normally set? - ans-Slightly above the initial balance point. The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is; - ans-The outdoor fan is inoperative. In order to determine a heat pumps' balance point, you must first calculate; - ans-The building's heat load. When a heat pump is used for heating and cooling, the system is sized by the; - ans-Cooling load. A high efficiency heat pump system designed to function from high to low ambient conditions below 10*F, may have? - ans-Two outdoor coils with each one incorporating a dual stage compressor.

Montrer plus Lire moins
Établissement
Esco
Cours
Esco









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Esco
Cours
Esco

Infos sur le Document

Publié le
5 avril 2024
Nombre de pages
11
Écrit en
2023/2024
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

Heat Pump ESCO Exam Questions And Answers
An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve
What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed defrost is based on time/temperature.
The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the; - ans-Outdoor ambient thermostat
The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the; - ans-Initial balance point
At what temperature is an outdoor ambient thermostat normally set? - ans-Slightly above the initial balance point.
The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is; - ans-The outdoor fan is inoperative.
In order to determine a heat pumps' balance point, you must first calculate; - ans-The building's heat load.
When a heat pump is used for heating and cooling, the system is sized by the; - ans-Cooling load. A high efficiency heat pump system designed to function from high to low ambient conditions below 10*F, may have? - ans-Two outdoor coils with each one incorporating a dual stage compressor.
Room thermostats for heat pumps should be installed; - ans-As near to the main return air grill as possible.
When the heat pump compressor has malfunctioned, the customer has the option to switch the system into; - ans-Emergency heat mode.
Start up with a night set back digital thermostat requires the technician to always; - ans-Teach the customer how to program the thermostat.
The heat pump defrost board can be manipulated by the technician to; - ans-Simulate the defrost cycle.
The air-to-air heat pump outdoor unit is most efficient if located; - ans-In a moderate climate zone.
Which of the following are innovations that may be found on new high efficiency units? - ans-ECM fan motors.
How may a lockout (impedance) relay be reset? - ans-Simply disconnect power to the unit momentarily.
The temperature difference between the 1st and 2nd bulbs for heating on a heat pump thermostat is; - ans-Approximately 2*F
SEER is calculated by; - ans-Dividing the Btu's removed by the watts consumed during the cooling season.
€9,67
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Prose1 Strayer University
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
610
Membre depuis
1 année
Nombre de followers
71
Documents
6469
Dernière vente
1 jours de cela
REALITIEXAM

I know how frustrating it can get with all those assignments mate. Nursing Being my main profession line, i have essential guides that are A graded, I am a very friendly person so don

4,5

297 revues

5
227
4
24
3
20
2
8
1
18

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions