F-80 Test Expert Verified Solutions
F-80 Test After what date was the F-24 certificate of Fitness not recognized. - ANS July 31, 2014 How often must this certificate be renewed? - ANS Every 3 years In what types of buildings and occupancies are coordinators of fire safety and alarm systems in homeless shelter required? - ANS Homeless shelters, one-way voice communication systems, or occupied for more tha n fifteen persons for a period of more than 30 days. What is the certificate of occupancy? - ANS Determines the number of occupants authorized to be in the shelter. Alarm Silence Switch - ANS Silences the building's audible and visual devices after evacuation is complete while the source of the alarm is being investigated. Building Occupants - ANS All persons in the shelter Carbon Monoxide Detector - ANS Device that senses carbon monoxide Central Station Company - ANS Receives alarm signals from a protected premise and retransmits or otherwise reports such alarm signals to the FDNY Evacuation - ANS Emptying of a building Emergency Preparedness Plan - ANS Provide the information, guidance, direction and assistance needed to protect the safety of building occupants. Fire Drill - ANS A training exercise Fire Guard - ANS Fire guards report any fire safety violations to the Coordinator of Fire Safety and Alarm Systems in Homeless Shelters. Fire Triangle - ANS A fire requires fuel, oxygen, and heat. Free Burning Stage of a Fire - ANS Second stage of the three stages of a fire. The fully developed stage of a fire. Incipient Stage of a Fire - ANS First stage of the three stages of a fire. The growth stage. In-Building Relocation Area (IBRA) - ANS A designated are in a building to which building occupants may be relocated Off-Line - ANS Periods of time when CS will, per request of building owner, not transmit fire alarm signals. One-Way Voice Communication - ANS Makes announcements from the lobby to building occupants in their apartments/rooms. Out of Service Signage - ANS placard (tag) over a defective device (job of impairment coordinator) Partial Evacuation - ANS The emptying of a building of some but no all building occupants in response to a fire or an emergency Phase 1 Emergency Elavator Recall - ANS Involves using a keyed switch to bring the elevators back to the lobby. Shall - ANS Refers to a requirement of the fire code Should - ANS Refers to policies, procedures, and practices recommended but not required. Smoldering Stage of a Fire - ANS The third stage in the three stages of a fire. Fire has an unlimited supply of fuel but limited oxygen. Visible flames will have diminished and the fire will smolder and continue to produce smoke and toxic gases. Unnecessary Alarm - ANS Response proved unnecessary. Unwarranted Alarm - ANS Result of improper installation, improper maintenance, malfunction, or other factor. How many people were estimated to have spent the night in a NYC homeles shelter in 2013. How many were children? - ANS 45,000. 19,000 children. It is imperative that Coordinators or Fire Safety and Alarms Systems in Homeless Shelters ensure: - ANS immediate correction of any fire safety violations and familiarity with emergency preparedness plan Fire summary of homelss shelter in Paris, Texas - ANS When: 2009 42 bed shelter 28 men Why: Ignition of table inside the shelter that was piled hight with donated clothing. 20 residents evacuated Five men were killed The building had no sprinkler system, fire alarms, or smoke detectors. Hadn't been inspected for at least five years Fire summary of homeless shelter in Bronx, NY - ANS When: December 7, 2012 and December 9, 2012 Why: Improperly stored mattresses were ignited in two separate incidents only two days apart. Two building occupants tried to use portable fire extinguishers to extinguish the fire but found them empty and inoperable Some of the fire escapes were broken Four adults and two children being seriously injured Fire summary of homeless shelter in New York, NY - ANS When: August 28, 2012 Complete evacuation Why: Lit cigarette left unattended by a tenant ignited a mattress on the fourth floor. How often must a Coordinator of Fire Safety & Alarm Systems in Homeless Shelters be present at the shelter? - ANS All times. How often does the building need to be patrolled by the fire guard? - ANS Every area of the building shall be patrolled at least once every hour. They must maintain records of their patrols. Where should the emergency preparedness plan be? - ANS A copy of the EPP must be maintained on the premises in an approved location and it shall be made available at all times to Fire Department representatives immediately upon request. How often should staff do refresher training sessions designed to familiarize them with their duties pursuant to the plan? - ANS 1 hour quarterly on each work shift
École, étude et sujet
- Établissement
- F80
- Cours
- F80
Infos sur le Document
- Publié le
- 27 mars 2024
- Nombre de pages
- 14
- Écrit en
- 2023/2024
- Type
- Examen
- Contient
- Questions et réponses
Sujets
-
f 80 test