Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4.2 TrustPilot
logo-home
Examen

NICET LVL 1 SG with 100% Correct Answers Updated & Verified

Note
-
Vendu
-
Pages
5
Grade
A+
Publié le
19-07-2023
Écrit en
2022/2023

If combination audible/ visible appliances are installed, the location of the installed appliance shall be determined by the requirements of the _____. <<Ans>> the visible appliance. The maximum number of 12- gauge THHN wires that can be installed in 1-inch EMT. <<Ans>> 26 Two resistors are connected in parallel. R1= 300 Ohms, R2=300 Ohms. What is their equivalent resistance? <<Ans>> 150 Ohms According to NFPA 72, visible notification appliances in non-sleeping areas must be mounted ____________ above the finished floor. <<Ans>> between 80 and 96 inches If fire alarm system impairment occurs, the owner must be notified in writing within _____. <<Ans>> 24 hours For visual notification, a 20x20 room with a 20 foot ceiling height requires at minimum a ______ ceiling mounted strobe. <<Ans>> 30 candella A 40x40 area with a 10 foot ceiling is best served by a _____ visible notification appliance, centered on one wall. <<Ans>> 60 candella Conductors returning to the fire alarm panel from the last field device suggests the circuit is wired as _____. <<Ans>> Class A Secondary power supply for a emergency voice/ alarm communications fire alarm system shall be capable of operating for a minimum of _____ in standby followed by ____ in alarm. <<Ans>> 24 hours/ 15 minutes Secondary power supplies shall automatically provide power within _____ of primary power failure. <<Ans>> 10 seconds Smoke detectors shall not be installed if the relative humidity is above _____. <<Ans>> 93 percent What does GFCI stand for? <<Ans>> Ground Fault Circuit Interrupter (GFCI) A fixed- temperature, non-restorable spot type heat detector shall be tested ____ from initial installation. <<Ans>> 15 years Heat detectors shall be selected to operate at least ____ above expected ambient temperature. <<Ans>> 20 degrees F Testing records shall be kept until the next test, as well as ____ additionally following that test. <<Ans>> 1 year _____ is responsible for storing and maintaining testing records. <<Ans>> The owner of the fire alarm system Household fire alarm system smoke detectors shall be tested ____ by a technician. <<Ans>> annually Inspection, testing, or maintenance of the fire alarm system shall be permitted to be done by the building or system owner or a person or organization other than the building or system owner if _____. <<Ans>> conducted under a written contract A manual pull station shall not be less than ____ and more than ____ from the finished floor. <<Ans>> 42/48 feet If the operation of a device, circuit, fire alarm control unit function, or special hazard system interface is simulated during a test, it must be _____. <<Ans>> documented on the testing form that the operation was simulated. What is the formula for determining total resistance of parallel resistors that have the same resistance value. <<Ans>> R= resistance / # of resistors For software based systems, a copy of the site specific software shall be provided to ____. <<Ans>> the system owner or owner's designated representative Manual pull stations shall be ___ in color. <<Ans>> red To determine the correct method of testing a fire alarm system component, refer to the table in NFPA 72, chapter ____. <<Ans>> 14.4.3.2 After a fire alarm system has been installed, the documentation should be stored ____. <<Ans>> in a document cabinet on the protected premises How should a non-restorable line type heat detector be tested? <<Ans>> Do not perform a heat test. Test functionality mechanically and electrically. Duct type smoke detectors shall be tested ___. <<Ans>> annually For installation of a heat detector with a listed spacing of 50 feet, what spacing should be used for a 20 foot ceiling that is smooth and flat. <<Ans>> 32 feet Smoke detectors that have provision for field adjustment of sensitivity shall have an adjustment range of ____ per foot obscuration. <<Ans>> not less than 0.6%

Montrer plus Lire moins
Établissement
NICET LVL 1 SG
Cours
NICET LVL 1 SG









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
NICET LVL 1 SG
Cours
NICET LVL 1 SG

Infos sur le Document

Publié le
19 juillet 2023
Nombre de pages
5
Écrit en
2022/2023
Type
Examen
Contient
Questions et réponses

Sujets

€9,29
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur
Seller avatar
Mawseron
4,0
(1)

Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Mawseron University of the People
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
6
Membre depuis
2 année
Nombre de followers
3
Documents
198
Dernière vente
1 année de cela

latest updated documents, correct, verified & graded A study materials

4,0

1 revues

5
0
4
1
3
0
2
0
1
0

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions