IRC Electrical Test with COMPLETE SOLUTION
Conductors in NM cable assemblies shall be rated at ___°C. - 90°C Watch out here, it also reads the 90°C rating shall be permitted to be used for ampacity correction and adjustment purposes provided that the final corrected or adjusted ampacity does not exceed that for a 60°C rated conductor. E3705.4.4 Conductors of type NM cable. Insulated conductors and cables exposed to direct rays of sun shall be listed and labeled ____ _____. - Sunlight resistant E3802.3.3 Locations exposed to direct sunlight. Where raceways are installed in wet locations above grade, the interior of such raceways shall be considered to be a ____ location. - Wet Insulated conductors and cables installed in raceways in wet locations above grade shall be listed for use in wet locations.