Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4.2 TrustPilot
logo-home
Examen

NYC MASTER ELECTRICIAN EXAM COMPLETE QUESTIONS AND OUTLINED ANSWERS

Note
-
Vendu
-
Pages
38
Grade
A+
Publié le
13-01-2026
Écrit en
2025/2026

NYC MASTER ELECTRICIAN EXAM COMPLETE QUESTIONS AND OUTLINED ANSWERS /. Type ____ is multiconductor cable identified for use as underground service entrance cable. - Answer-Type USE cable /.Knife switch rated for more than 1200 Amps at 250Volts or less - Answer-Can be used only as isolating switch, shall not be opened under load /.Track lighting with outlets in a bathroom is not allowed because ? - Answer-Track lighting has receptacle /.Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system - Answer-6 hours /.Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - Answer-30 Amps /.Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - Answer-Both ends /.GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. - Answer-Locking /.The maximum voltage drop from service point to the last over-current device in a dwelling unit? - Answer-4% /.Which of the following statements best describe the grounding requirement for central vacuum outlet - Answer-Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. /.In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system - Answer-Are permitted /.Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas - Answer-Do not include /.The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. - Answer-Examined or treated /.Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles - Answer-Single or two /.A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients - Answer-Four /.Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment - Answer-Listed fitting /.Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature - Answer-3 inches /.Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not exceeding ____ ft. - Answer-6 ft /.Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a ____ that shall be visible with the screw installed - Answer-Green finish /.Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere rating - Answer-Hexagon /.The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each dryer served ? - Answer-5000 watts /.Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____ windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. - Answer-3 ft (36 inches) /.—— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing installation is where there is no evidence of over-fusing or tampering. - Answer-Class H /.Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower it 90°C 194°F - Answer-3" inches /.The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. - Answer-8 /.In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? - Answer-Combination range hood/microwave oven /.Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device up to the equipment ____ the type 3 SPD connection must be a minimum 30'ft of conductor a distance from the service or separately derived system disconnect - Answer-Included in the manufactures instructions /.Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? - Answer-EVJ /.Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be removed - Answer-Type S fuse /.Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and unless a lesser distance is permitted by and exceptions - Answer-8'ft /.Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or similar fittings with conductors of Class 1 or electric light or power conductors, unless ____. - Answer-Separated by barrier /.In the critical care areas of health care centers, each patient bed shall be provided with a minimum of ____ duplex receptacles - Answer-3 duplex (6 single) /.The equipment system shall supply major electric ____ necessary for patient care and basic hospital operation - Answer-Equipment /.The essential electrical system in a healthcare facility shall be compromised of the - Answer-emergency system and the: equipment system /.Locations were flammable anesthetics are employed are class I,Division I locations that shall extend - Answer-upwards to a level 5'ft above the floor /.In a healthcare facility receptacles and attachment plugs in a hazardous (classified) location with an anesthizing area shall be listed for use in class I group ____ locations - Answer-Group C /.In anesthetic,areas health care equipment frequently in contact with bodies of persons shall not exceed ____ volts. - Answer-10 Volts

Montrer plus Lire moins
Établissement
NYC MASTER ELECTRICIAN
Cours
NYC MASTER ELECTRICIAN










Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
NYC MASTER ELECTRICIAN
Cours
NYC MASTER ELECTRICIAN

Infos sur le Document

Publié le
13 janvier 2026
Nombre de pages
38
Écrit en
2025/2026
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

NYC MASTER ELECTRICIAN EXAM
COMPLETE QUESTIONS AND OUTLINED
ANSWERS

/. Type ____ is multiconductor cable identified for use as underground service entrance
cable. - Answer-✅Type USE cable

/.Knife switch rated for more than 1200 Amps at 250Volts or less - Answer-✅Can be
used only as isolating switch, shall not be opened under load

/.Track lighting with outlets in a bathroom is not allowed because ? - Answer-✅Track
lighting has receptacle

/.Where internal combustion engines are used as the prime motor, an on site fuel supply
shall be provided with an on premise fuel supply sufficient for not less than ____ hours
full demand operation of the system - Answer-✅6 hours

/.Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over
____ amperes shall be permitted to be supplied through a suitable attachment plug cap
and hard service cable cord. - Answer-✅30 Amps

/.Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - Answer-
✅Both ends

/.GFCI protection at a carnival is not required for equipment at circuit if the receptacle is
of the ____type. - Answer-✅Locking

/.The maximum voltage drop from service point to the last over-current device in a
dwelling unit? - Answer-✅4%

/.Which of the following statements best describe the grounding requirement for central
vacuum outlet - Answer-✅Accessible non current carrying metal parts are required to
be connected to an equipment grounding conductor.

/.In healthcare facilities, patient bed receptacles located in general care areas shall be
supplied by at least two branch circuits, which ____permitted to originate from two
separate transfer switches on the emergency system - Answer-✅Are permitted

,/.Patient care areas of healthcare facilities ____ areas such as business offices,
corridors, lounges ,day rooms, or similar areas - Answer-✅Do not include

/.The patient care area is any portion of the healthcare facility where patients are
intended to be ____or ____. - Answer-✅Examined or treated

/.Each general care area patient bed location in a healthcare facility must be provided
with four ____ or ____ duplex receptacles - Answer-✅Single or two

/.A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or
surgical, care on a 24 hour basis of ____ or more patients - Answer-✅Four

/.Where installed to reduce electrical noise for electronic equipment, electrical continuity
of the metal raceways shall not be required and metal raceway can terminate a (an)
____ nonmetallic fitting or spacer on electronic equipment - Answer-✅Listed fitting

/.Feeder and branch circuit conductors within ____ inches of a Ballast shall have an
insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere
marked as suitable for a different insulation temperature - Answer-✅3 inches

/.Manufactured wiring systems constructed with type MC cable shall be supported and
secured at intervals not exceeding ____ ft. - Answer-✅6 ft

/.Where a main bonding jumper or a system bonding jumper is a screw only the screw
shall be identified with a ____ that shall be visible with the screw installed - Answer-
✅Green finish

/.Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of
the window, cap, or other prominent part to distinguish them from fuses of higher
ampere rating - Answer-✅Hexagon

/.The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____
watts (volt-amperes) or the nameplate rating, which ever is larger, for each dryer served
? - Answer-✅5000 watts

/.Service conductors installed as unjacketed multiconductor cable shall have a minimum
clearance of ____ windows that are designed to be opened, doors, porches, stairs fire
escape or similar locations. - Answer-✅3 ft (36 inches)

/.—— Cartridge fuses of the renewable type shall be permitted to be used only for
replacement in existing installation is where there is no evidence of over-fusing or
tampering. - Answer-✅Class H

, /.Branch circuit conductors within ____inches of the ballast shall have an insulation
temperature rating not lower it 90°C 194°F - Answer-✅3" inches

/.The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. - Answer-✅8

/.In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment
ground plug ? - Answer-✅Combination range hood/microwave oven

/.Type 3 Surge Protective devices can be installed on the load side of a branch circuit
overcurrent device up to the equipment served.if ____ the type 3 SPD connection must
be a minimum 30'ft of conductor a distance from the service or separately derived
system disconnect - Answer-✅Included in the manufactures instructions

/.Which flexible cable is Allowed to be used for electric vehicle charging station 300
Volts ? - Answer-✅EVJ

/.Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that
cannot be removed - Answer-✅Type S fuse

/.Service drops Installed over roof shall have a vertical clearance of ____ above the roof
surface, and unless a lesser distance is permitted by and exceptions - Answer-✅8'ft

/.Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or
similar fittings with conductors of Class 1 or electric light or power conductors, unless
____. - Answer-✅Separated by barrier

/.In the critical care areas of health care centers, each patient bed shall be provided with
a minimum of ____ duplex receptacles - Answer-✅3 duplex (6 single)

/.The equipment system shall supply major electric ____ necessary for patient care and
basic hospital operation - Answer-✅Equipment

/.The essential electrical system in a healthcare facility shall be compromised of the -
Answer-✅emergency system and the: equipment system

/.Locations were flammable anesthetics are employed are class I,Division I locations
that shall extend - Answer-✅upwards to a level 5'ft above the floor

/.In a healthcare facility receptacles and attachment plugs in a hazardous (classified)
location with an anesthizing area shall be listed for use in class I group ____ locations -
Answer-✅Group C

/.In anesthetic,areas health care equipment frequently in contact with bodies of persons
shall not exceed ____ volts. - Answer-✅10 Volts
€15,92
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
kartelodoc Harvard University
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
119
Membre depuis
1 année
Nombre de followers
4
Documents
8114
Dernière vente
6 jours de cela

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Lire la suite Lire moins
3,2

22 revues

5
7
4
1
3
7
2
3
1
4

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions