CERTIFICATION FOR LONG TERM MONITORING EXAM
WITH 2 VERSIONS (VERSION A & B) WITH COMPLETE
1200 REAL EXAM QUESTIONS AND CORRECT DETAILED
ANSWERS (VERIFIED ANSWERS) GRADED A+| CLTM
EXAM PREP 2025 (BRAND NEW!!)
What does OSHA stand for? - answer-;Occupational Saftey & Health
Administration
OSHA function (select one)
a. Prevents wrong-site surgery
b. Protects Private Patient Health Information
c. Insures an environment of patient safety
d. insures and environment of safety for the staff - answer-;insures an
environment of safety for the staff
EEG changes can be seen when cerebral blood flow falls below
a) 75 - 80 mL/100g/minute
b) 40-45 mL/100g/minute
c) 25-30 mL/100g/minute
,d) 95-100 mL/100g/minute - answer-;C. 25-30 mL/100g/minute
T1 and T2 electrode placement
a) 1 cm superior to 1/3 of the distance from the external eye canthus and the
tragus (third closest to tragus)
b) Between C3/T3 and C4/T4
c) On the mastoid bone behind the ear
d) Below the zygomatic arch, 2 cm anterior to the line between the tragus and the
mandible - answer-;A. 1 cm superior to 1/3 of the distance from the external eye
canthus and the tragus (third closest to tragus)
Which of the following electrodes from the 10-10 system would be useful on a
patient with suspected benign rolandic epilepsy?
a) FT9
b) AF4
c)CP1
d)PO3 - answer-;C. CP1
In the proposed 10-10 system what is the designation of the intermediate chain
between the fronto-polar and frontal leads
a) Frontal central
b) Anterior frontal
c) Frontopolar - frontal
d) Anterior frontopolar - answer-;B. Anterior frontal
,What is the most common spacing of electrodes disks on a 4 point intracranial
strip?
a) 1 cm
b) 2 cm
c) 15 mm
d) 5 mm - answer-;A. 1 cm
An electrode application technique considered the only method that will insure a
stable long term scalp recording is
a) Electrode cap
b) Needle electrdoes
c) Electrode paste alone
d) Collodion - answer-;D. Collodion
Subdural electrodes are commonly composed of
a) Copper
b) Platinum
c) Siler
d) Chloride silver - answer-;B. Platinum
For stimulation of median nerve somatosensory evoked potentials, utilizing a pair
of stimulating electrodes the cathode is placed?
a) Dorsal
b) Distal
c) Proximal
, d) Ventral - answer-;C. Proximal
Strip and grid electrodes are separated by inter-electrode distances of
a) 50 - 100 mm
b) 0.5 to 1 cm
c) 5 to 10 cm
d) 0.5 to 1 mm - answer-;B. 0.5 to 1 cm
What type of material is favored for Stereo EEG electrodes due to its MRI
compatible properties?
a) Silver
b) Copper
c) Nickel-chromium composite
d) Stainless steel - answer-;C. Nickel-chromium composite
Strip electrodes are usually inserted through a
a) Ear canal
b) Nasal cavity
c) Burr hole
d) Oral cavity - answer-;C. Burr hole
Nasopharyngeal electrodes are no longer utilized for LTM due to
a) Lack of proven benefit
b) Prominent artifact created
c) All are correct