TEST EXAM WITH CORRECT ACTUAL
QUESTIONS AND CORRECTLY WELL
DEFINED ANSWERS LATEST ALREADY
GRADED A+ 2025 – 2026
Why do air sampling pumps need to be calibrated before
use? - ANSWERS--You must know exactly how much air is
pulled through the monitoring cassette in order to have
accurate readings
Why is personal air sampling required to assess worker's
lead exposure - ANSWERS-Because it represents what an
employee's actual exposure is
Describe potential health hazards from chemicals used on
the job and recommended ways to prevent exposure -
ANSWERS--Burns
-Eye damage
,-Fire
-Fumes
Prevention:
Follow manufacturers recommendations
Identify safety data sheets needed at the work site -
ANSWERS-Needed for chemicals and products used at the
job site
-WD40
-Encapsulants
-Treated lumber
-Paint
-Caulk
-Detergent
-Primer
Describe the OSHA ( and other requirements) for lead
abatement worker training - ANSWERS-Info on respirators
and their use, types, proper fit
Medical exams for everyone working with lead
,Describing what your employer is doing to reduce your
exposure to lead
Describe the RCRA regulations and regulated information
regarding waste disposal for lead abatement projects -
ANSWERS-Commercial/ industrial projects- tested, labeled,
hauled correctly
Residential property- household hazardous waste
exemption
Identify the lead RCRA definitions of hazardous waste and
testing procedures - ANSWERS-TCLP test- toxic characteristic
leaching procedure
Detects how much lead would leach out of the waste.
5mg/l= hazardous waste
Lead meets the toxicity part of being a hazardous waste
"Competent Person for health and safety" as defined by
OSHA - ANSWERS-A person who can identify hazards
Someone who can take corrective action
, OSHA respirator protection standards relevant to lead
abatement work - ANSWERS-When above the permissible
exposure limit:
Need to wear HEPA filter and any other appropriate filter
Have a written respiratory program in place
OSHA general industry standards relevant to lead
abatement work - ANSWERS-Similar to the construction rule
except: it pertains to exposure to lead when it is not
Construction
Agriculture
Factory manufacturing
Medical removal is different
Return to work level is different
Describe blood monitoring requirements - ANSWERS-If air
monitoring is above the action level
30ug/m3 for more than 30 days/year
Every 2 months for the first 6 months