100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!

Puntuación
-
Vendido
-
Páginas
38
Grado
A+
Subido en
26-11-2025
Escrito en
2025/2026

Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!

Institución
Q-01 FDNY
Grado
Q-01 FDNY











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Q-01 FDNY
Grado
Q-01 FDNY

Información del documento

Subido en
26 de noviembre de 2025
Número de páginas
38
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!




Rupture members, when used in parallel with a relief valve, are not to exceed _____% above designed
working pressure -(ANSWER)20%



Butterfly valve: where can it be used? -(ANSWER)Can be used on the inlet and outlet of a water pump



What electrical motor protection device automatically resets itself? -(ANSWER)The thermal protector



746 watts equals how many kilowatt hours? -(ANSWER).746 kilowatt hours



What position is the liquid line service valve normally in? -(ANSWER)Back-seated



In an operating evaporator, oil stays on top of which refrigerant? -(ANSWER)Carbon dioxide, R-744



At what pressure does the relief valve blow on a high pressure machine? -(ANSWER)300 psi



What would indicate a restriction (such as dirt or scale) in the liquid line? -(ANSWER)Frost immediately
after the restriction



What does solubility mean? -(ANSWER)The ability of a refrigerant to mix with other substances



Charging Vapor —In a compression system, where do you charge the vapor? -(ANSWER)Suction side of
the compressor at the Suction Service Valve



When comparing a brine with s PH of 8 to one with a PH of 10, its alkalinity is: -(ANSWER)100 times
greater (ex. PH 8 to PH 9 is 10 times greater)



In an efficiently operating induced draft cooling tower, the leaving water is between: -(ANSWER)Dry
bulb and wet bulb temperature

,Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!




To produce the desired evaporator temperature, the power input is reduced by keeping head pressure...
-(ANSWER)Head pressure as low as possible & suction pressure as high as needed



The accumulator is usually between the... -(ANSWER)Compressor and evaporator



An oiling system in a large centrifugal system should consist of at least... -(ANSWER)Reservoir, pump and
distribution lines



In an evaporator that chills brine, the greatest cooling effect on the brine results from the... -
(ANSWER)Boiling of low pressure liquid



The flow of weak liquor to the absorber is controlled by

A) gas pressure

B) throttling device

C) float valve

D) pressure of the strong liquor pump -(ANSWER)B) throttling device



The best way of detecting ammonia brine is by using

A) CO2 gas

B) potassium of lime

C) Nessler reagent

D) carbonate of soda -(ANSWER)C) Nessler reagent



The best time to purge an ammonia plant with 250 lbs. of ammonia is

A) during shut-down, because you will lose ammonia

B) while charging the plant

C) during operation

D) none of the above -(ANSWER)C) during operation

,Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!




What will make the strong liquor in the absorber decrease?

A) expansion valve open too much

B) A decrease in evaporator load

C) An increase in evaporator load

D) Too much steam on the generator -(ANSWER)B) A decrease in evaporator load



Which of the following statements is incorrect?

A) A service valve is a key-operated shut-off valve used during shipment, installation and repairs

B) Brine is a liquid cooled by refrigeration and used for the transmission of heat

C) A fusible plug has a set-temperature fusible member to relieve pressure

D) A rupture member automatically ruptures at a predetermined temperature -(ANSWER)D) A rupture
member automatically ruptures at a predetermined temperature



Oil in a refrigerant should

A) have a high pour point

B) have a low flash point

C) have a high viscosity

D) not contain moisture -(ANSWER)D) not contain moisture



In an NH3 dry expansion evaporator with TXV and bulb clamped properly on the outlet of the
evaporator, the superheat is

A) 7 to 10° F

B) 5 to 9° F

C) 20 to 30° F

D) 1 to 2° F -(ANSWER)A) 7 to 10° F



The setting of a fusible plug is

, Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!




A) 280° F

B) 300° F

C) 380° F

D) 300 psig. -(ANSWER)A) 280° F



If the insulation was removed from the bulb of the expansion valve, what would happen? -
(ANSWER)Flooded evaporator —the TXV bulb opens in a range from 45 to 85° F. If the insulation was
removed, the bulb would sense the temperature in the machine room and keep the TXV open, thus
flooding the evaporator.



On the most common three-phase, four-wire service, the voltage between any phase and neutral should
be

A) 105 volts

B) 120 volts

C) 208 volts

D) 220 volts -(ANSWER)B) 120 volts



A refrigerant overcharge would

A) increase head pressure

B) decrease head pressure

C) decrease solution-side pressure

D) decrease discharge-side pressure -(ANSWER)A) increase head pressure



A dryer is generally installed with other equipment in a commercial Freon compressor system. The
recommended location of this dryer is on the

A) high-pressure line between condenser and reciever

B) suction line between evaporator and compressor

C) discharge line between compressor and condenser
$21.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NursAid Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
7 meses
Número de seguidores
1
Documentos
235
Última venta
21 horas hace

I OFFER QUALITY A+ GRADED DOCS....WELCOME ALL

5.0

8 reseñas

5
8
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes