100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NICET LEVEL 3 TEST|QUESTIONS AND 100% CORRECT WELL DETAILED ANSWERS|LATEST UPDATE!!!!2025/2026|GUARANTEED PASS|GRADED A+

Puntuación
-
Vendido
-
Páginas
18
Grado
A+
Subido en
24-11-2025
Escrito en
2025/2026

NICET LEVEL 3 TEST|QUESTIONS AND 100% CORRECT WELL DETAILED ANSWERS|LATEST UPDATE!!!!2025/2026|GUARANTEED PASS|GRADED A+

Institución
Nicet
Grado
Nicet










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Nicet
Grado
Nicet

Información del documento

Subido en
24 de noviembre de 2025
Número de páginas
18
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

CORRECT WELL DETAILED ANSWERS|LATEST
UPDATE!!!!2025/2026|GUARANTEED


One smoke detector on the 26 inch side

(NFPA 72 17.7.56.51) - ANSWER Consider the use of smoke detectors for door release.
The depth of the wall section above the door is 24 inches on one side of the doorway. The
depth of the wall section above the door on the other side is 26 inches. Based on this, the
most appropriate smoke detector installation according to NFPA 72 is _____?



36

(NFPA 72 24.8.17) - ANSWER Wall mounted telephone appliances shall be not less
than _____ inches AFF?



2 revolutions

(NFPA 72 17.16.1.2) - ANSWER Consider a control valve switch installed on a butterfly
valve. The off normal signal shall be initiated within _____ of the travel distance from the
normal position?



Contract price

Payment terms

Payment terms

(Project management reference) - ANSWER Which of the following is an important
contract provision? (Select Three)

Contract price

Profit margin

Payment terms


1

,Payment terms



They represent a legal contract.

They include General Clauses.

They include Technical Instructions.

(Project management reference) - ANSWER Which of the following is true regarding
project specifications? (Select Three)

They represent a legal contract.

They include General Clauses.

They include Technical Instructions.

They include the architectural drawings.



2-1

(NFPA 72 Table A.10.11.4) - ANSWER Consider a building which has 4 floors and
multiple basements. The recommended coded signal for the first floor is _____?



2

(NFPA 72 Table 18.5.5.4.1(a)) - ANSWER Consider a residential common area which is
30 feet x 50 feet which requires the use of strobes. The strobes are ceiling mounted strobes.
The ceiling is 10 feet AFF. A total of _____ strobe(s) rated at 30 cd are required?



1

(NFPA 72 Table 18.5.5.4.1(a)) - ANSWER Consider a mechanical room which is 30 feet x
30 feet which requires the use of strobes. The strobes are wall mounted strobes. A total of
_____ strobe(s) rated at 34 cd are required?



4 (NFPA 72 A.23.2.2.2) - ANSWER Consider the installation of a protected premises fire
alarm system. All software and firmware shall be protected against unauthorized access.
Access by persons who have a specific responsibility for safety and who are trained to
operate the control unit should be considered Access Level _____?


2

, 20 (NFPA 72 17.7.3.2.4.2(1)) - ANSWER Consider a 120 feet x 150 feet room which has
a ceiling surface with beams which are 15 inches deep and spaced at 4 feet apart. The ceiling
is 14 feet AFF and level. The beams run the parallel to the 150 foot length of the room.
Based on this a total of _____ smoke detectors are required?



5 (NFPA 72.24.8.6) - ANSWER NFPA 72 requires that two way telephone
communications service shall be capable of permitting the simultaneous operation of any
_____ telephone stations in a common talk mode?



Voice intelligibility is required

(NFPA 72 7.3.4.4) - ANSWER The documentation for notification appliances shall
identify acoustically distinguishable spaces (ADS) when _____?



41

(NFPA 72 Figure A.17.6.3.1.1.1(g)) - ANSWER Consider a corridor which is 10 feet wide
with a smooth and level ceiling. The maximum spacing between spot type smoke detectors
is _____ feet?



Psychiatric hospital

(IBC 308) - ANSWER According to the IBC, a _____ is not considered a Use Group I-1?

Convalescent facility

Alcohol and drug center

Halfway house

Psychiatric hospital



One half

(NTC Brown Book) - ANSWER Consider speakers tapped at 1/8 watt and produce a
sound level of 82 dBA at 10 feet. In order to produce a sound level of 70 dBA at 80 feet, the
speakers should be tapped at _____ watt?



3
$13.79
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Spotlight1 Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
14
Miembro desde
11 meses
Número de seguidores
1
Documentos
4701
Última venta
2 semanas hace
A+ GRADED AND VERIFIED STUDY MATERIALS

Tested, UPDATED,Verified and 100% CORRECT Study Materials with 100% Guaranteed Success.

4.0

3 reseñas

5
2
4
0
3
0
2
1
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes