(NFPA 72 14.4.4.5.1) - THE CORRECT ANSWER-Two detectors or more
on each initiating device circuit
According to NFPA 72 how many spot type heat detectors are
required for a space that is 80' long and 55 floor wide with a
smooth 10' ceiling? the detector is listed for a maximum space
between detectors of 30' - THE CORRECT ANSWER-6
What color code requirement for a spot type heat detector rated
at 200゚F - THE CORRECT ANSWER-White (NFPA 72, Table 17.6.2.1)
Unless otherwise recommended by the manufacturers
published instructions single and multiple stations smoke
alarms installed in one and 2 family dwellings shall be replaced
every - THE CORRECT ANSWER-10 years from the day-of manufacture.
(NFPA 72, 14.4.7.1)
Fire alarm cables are permitted to be strapped to conduit to
support the cable - THE CORRECT ANSWER-False (NEC 760.143)
,Where non power limited wiring is installed exposed it must be
mechanically protected within_____of the finished floor - THE
CORRECT ANSWER-7' ft
Fire-Warning equipment to be installed in residential
occupancies shall produce the audible emergency evacuation
signal described in - THE CORRECT ANSWER-ANSI S3.41
According to NFPA 72, visible notification appliance for non-
sleeping areas must be mounted between ___ and ___ inches
above the finished floor - THE CORRECT ANSWER-80 & 96
If system impairment occurs, the owner must be notified ___
within ___ - THE CORRECT ANSWER-in writing & within 24 hours
A 20 X 20' ft room with a 20'ft high ceiling requires at a
minimum a ___ ceiling mounted strobe - THE CORRECT ANSWER-30
candela
According to NFPA 72, a 40 x 40'ft room or area with a 10'ft
ceiling is best covered by a ___ cd visible notification
appliance, centered on one wall. - THE CORRECT ANSWER-60
Conductors returning to the fire alarm control panel (FACP)
from the last field device on the circuit might indicate a _____
circuit - THE CORRECT ANSWER-Class A
, Secondary power supplies for an emergency voice/alarm
communication fire alarm system shall be capable of operating
for minimum of ___ of standby followed by ___ of alarm. - THE
CORRECT ANSWER-24 hrs & 15 mins
The fire alarm system primary power branch circuit
disconnecting means must be ___ in color. - THE CORRECT ANSWER-
Red
The secondary power supply for protected premises shall
automatically provide power within ___ seconds when primary
power fails. - THE CORRECT ANSWER-10 seconds
Under which of the following conditions shall spot-type smoke
detectors NOT be installed? - THE CORRECT ANSWER-When the
temperature is over 100*F
Who is responsible for maintaining Personal Protective
Equipment? - THE CORRECT ANSWER-YOU, the employee
What does GFCI stand for ? - THE CORRECT ANSWER-Ground Fault
Circuit Interrupter
A fixed-temperature, non-restorable spot type heat detector
shall be tested ____ from initial installation. - THE CORRECT
ANSWER-15 years after
Heat detectors should be selected to operate at least ___
degrees Farenheit above the maximum expected ambient