100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NERC Certification End of Class Test all 600 QUESTIONS AND CORRECT ANSWERS LATEST UPDATE THIS YEAR NEW!!

Puntuación
-
Vendido
-
Páginas
160
Grado
A+
Subido en
22-10-2025
Escrito en
2025/2026

NERC Certification End of Class Test all 600 QUESTIONS AND CORRECT ANSWERS LATEST UPDATE THIS YEAR NEW!!

Institución
NERC Certification
Grado
NERC Certification











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NERC Certification
Grado
NERC Certification

Información del documento

Subido en
22 de octubre de 2025
Número de páginas
160
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Page 1 of 160




NERC Certification End of Class Test all 600

QUESTIONS AND CORRECT ANSWERS LATEST

UPDATE THIS YEAR NEW!!
NERC Certification End of Class Test


If a line is loaded above its SIL, how does that affect the line and the voltage?

A. The line becomes less inductive and the voltage drops.

B. The line becomes more inductive and the voltage drops.

C. The line becomes less inductive and the voltage increases.

D. The line becomes more inductive and the voltage increases.


B. The line becomes more inductive and the voltage drops.


Feedback: The Surge Impedance Loading, or SIL, is the MW loading on a transmission line at

which the line's natural reactive power production equals its reactive power usage. If the MW

loading exceeds the SIL the transmission line will consume more MVAR than it is producing

causing voltage to decline. VAR-001 ensures that voltage levels, reactive flows, and reactive

resources are monitored, controlled, and maintained within limits in Real-time to protect

equipment and the reliable operation of the Interconnection. - NERC Standard VAR-001


What direction do MVARs typically flow in a power system?

A. Higher voltage to lower voltage magnitude



1

,Page 2 of 160


B. On a decreasing power angle

C. Higher to lower voltage angle

D. Lower voltage to higher voltage magnitude


A. Higher voltage to lower voltage magnitude


Feedback: EPRI Tutorial, Chapter 4


Two adjacent lines exist in a Balancing Area that are the same length and have the same

ratings. One line is overhead and the other is underground. How do these two lines respond

as load picks up through the day?

A. The overhead line will carry more of the load increase

B. The underground cable will carry more of the load increase

C. The load increase will be distributed evenly over the two lines

D. The line with the higher impedance will carry more of the load increase.


B. The underground cable will carry more of the load increase


Feedback: EPRI Tutorial: Due to its higher capacitive property, the underground cable will have

lower impedance and therefore carry more of the increase.


Protective relays , such as Transmission Line relays and Transformer Differential relays, have

current flowing to them that is proportional to the current in the primary circuit. What is used

to transform the current from the primary circuit to the smaller proportional amount that

flows to the protective relay?

A. Current Transformers


2

,Page 3 of 160


B. Series Capacitors

C. Voltage reduction relays

D. Potential Transformers.


A. Current Transformers


Feedback: High voltage transmission equipment has high current and high voltage present on it

all the time. To protect this equipment and to monitor what is going on at any given time,

protective relaying and metering are needed and used. It would be impractical to direct this

high current and voltage into a small relay. So current transformers are used to supply a small

proportional amount of current to the relays and meters. This small proportional amount of

current is produced by Current Transformers connected to each phase of the primary circuit. As

current passes through the primary, a secondary current then flows to the relay or meter.-

NERC Standard PRC-001


What is the penalty for a Balancing Authority violating the Disturbance Control Standard?

A. Must increase its Regulating Reserve

B. Must develop a correction plan

C. Must carry additional Contingency Reserve

D. Must re-evaluate and change its Frequency Bias Setting


C. Must carry additional Contingency Reserve


Balancing Authority B has scheduled interchange of 100 MW from Balancing Authority A and

50 MW to Balancing Authority C. Actual interchange is 115 MW from Balancing Authority A



3

, Page 4 of 160


and 45 MW to Balancing Authority C. What is the inadvertent interchange for Balancing

Authority B?

A. 40 MW

B. 20 MW

C. -20 MW

D. -40 MW


C. -20 MW


Feedback: Inadvertent Interchange = NIA - NIS Actual = -115 + 45 = -70 Scheduled = -100 +50 = -

50Inadvertent = -70 - (-50) = -20"Each Balancing Authority shall calculate and record hourly

Inadvertent Interchange."- NERC Standard BAL-006


A Balancing Authority's ACE averages zero for the hour. At the end of the hour the Balancing

Authority operator notices that the Inadvertent for the hour was +20. What is the likely cause

of this Inadvertent?

A. Average frequency was high during the last hour.

B. Frequency was exactly 60 Hz for the entire last hour.

C. Average frequency was low during the last hour.

D. The average frequency for the last hour was 60 Hz.


C. Average frequency was low during the last hour.


Feedback: Since the BA's inadvertent was positive for the hour, the average NIA was greater

than the NIS. Also, the ACE averaged zero for the hour, which means frequency had to average



4
$27.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STUVIAGRADES Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
6178
Miembro desde
3 año
Número de seguidores
446
Documentos
5042
Última venta
23 horas hace
stuvia_US

Welcome To my Store# STUVIA_US My Goal is to help you achieve your desired grades by providing credible study materials I'm happy to help you with quality documents On this page you will find quality study guides,Exams assignments, Research papers and Test Banks all verified correct . you'll find past and recent revised and verified study materials . Stay here and You'll find everything you need to pass !!! . I always ensure my documents are of high standards I am always available to assist 24/7 and answer any queries you may have . Be assured to get good grades and always leave a review after a purchase Refer a friend SUCCESS!!!!

Lee mas Leer menos
4.8

1061 reseñas

5
980
4
27
3
22
2
11
1
21

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes