100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NICET FIRE ALARM LEVEL 1 EXAM | WITH COMPLETE QUESTIONS AND ANSWERS | 2025/206 LATEST UPDATED | 100 % RATED AND VERIFIED SOLUTIONS | GET AN A+

Puntuación
5.0
(1)
Vendido
-
Páginas
16
Grado
A+
Subido en
04-10-2025
Escrito en
2025/2026

NICET FIRE ALARM LEVEL 1 EXAM | WITH COMPLETE QUESTIONS AND ANSWERS | 2025/206 LATEST UPDATED | 100 % RATED AND VERIFIED SOLUTIONS | GET AN A+

Institución
NICET FIRE ALARM LEVEL 1
Grado
NICET FIRE ALARM LEVEL 1










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NICET FIRE ALARM LEVEL 1
Grado
NICET FIRE ALARM LEVEL 1

Información del documento

Subido en
4 de octubre de 2025
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NICET FIRE ALARM LEVEL 1 EXAM | WITH COMPLETE QUESTIONS

AND ANSWERS | 2025/206 LATEST UPDATED | 100 % RATED AND

VERIFIED SOLUTIONS | GET AN A+

When a device is inaccessible due to excessive height, such as an atrium, what it the maximum

interval for testing? - (ANSWER)18 months




When installing a wall-mounted fire telephone appliance to the public, what is the acceptable

maximum mounting height from the floor? - (ANSWER)66 inches




Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the

center-line of the door? - (ANSWER)21 feet




At minimum, when working near power lines with voltage of 600 volts and lower, an aerial lift

operator shall maintain which distance from the lines? - (ANSWER)10 feet




The use of unprotected EMT shall be permitted under which conditions? - (ANSWER)when in

direct contact with the earth




According to NFPA 70, what is the maximum unsupported length of 1/2-inch flexible metallic

conduit where flexibility is required after installation? - (ANSWER)4 1/2 feet

,What is the maximum bend (in degrees) permitted in a conduit run between outlet boxes? -

(ANSWER)360 Degrees




If the primary power is disconnected and the fire alarm system goes into an alarm condition,

what is the minimum acceptable time for secondary power to operate the voice evacuation

systems? - (ANSWER)15 minutes




A riser room temperature switch should activate when the temperature falls below which level? -

(ANSWER)40 degrees F




According to NFPA 72, what is the maximum sound pressure level permitted in a space with

notification appliances? - (ANSWER)110 dBA




What is the minimum interval for testing a single-station smoke detector in multifamily units? -

(ANSWER)Annually




Where should a technician install a detector in relation to beam that is less than 12 inches deep

and less that 8 feet in center? - (ANSWER)At the bottom of the beam

, An existing fire alarm cable in a drop ceiling will be spliced. which one of the following splice

locations will comply with NFPA 70? - (ANSWER)secured inside a listed box or enclosure




Which function shall be tested for each newly installed smoke detector? - (ANSWER)smoke

entry?




An 180 foot long corridor is 10 feet wide, with a smooth 10 foot ceiling, interrupted by 4-inch

beams spaced every 10 feet. How many heat detectors with a listed 30 foot spacing are required?

- (ANSWER)6 heat detectors




At which height must cables be physically protected when being installed within an exposed

ceiling? - (ANSWER)7 feet




When shall smoke detectors be installed during the construction process? - (ANSWER)After

the final cleanup of all trades




Where structural members are provided, intermediate metal conduit shall be secured within

which maximum distance from an outlet box" - (ANSWER)3 feet
$16.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Reseñas de compradores verificados

Se muestran los comentarios
3 días hace

5.0

1 reseñas

5
1
4
0
3
0
2
0
1
0
Reseñas confiables sobre Stuvia

Todas las reseñas las realizan usuarios reales de Stuvia después de compras verificadas.

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ELENAJAY New York University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
10
Miembro desde
1 año
Número de seguidores
0
Documentos
686
Última venta
17 horas hace
ELENAJAY Study Hub

Welcome to ELENAJAY Study Hub – your one-stop shop for academic success. I provide actual exams, test banks, study guides, case studies, summaries, and package deals tailored to help you prepare smarter and score higher. Whether you need quick revision notes or full exam prep bundles, you’ll find trusted resources here to match your study needs. All documents are provided in English!!!!

5.0

215 reseñas

5
206
4
9
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes