The ultimate goal of any fire and life safety inspection program is to: A.
identify building code violations.
B. avoid the majority of uncontrolled fires.
C. ensure building owners comply with the permit process.
D. establish a process of preplan inspections in jurisdictions. - ANSWER-B. avoid the majority of
uncontrolled fires.
Building codes typically allow a reduction in the hourly rating of the fire walls when the building:
A. utilizes compartmentalization
B. is equipped with sprinkler systems.
C. is built using fire-resistive construction
D. is built using non-combustible construction. - ANSWER-B. is equipped with sprinkler systems
How must steel that has been incorporated into a fire wall be protected in steel-frame buildings? A.
There is no requirement for protection beyond natural qualities.
B. It is required to be enclosed within a fire-rated structure.
C. It must be protected with spray-on insulation or other barriers.
D. It must provide the same degree of fire resistance as the fire wall. - ANSWER-D. It must provide the
same degree of fire resistance as the fire wall.
What special treatments are required when a combustible structural member penetrates through a fire
wall?
A. They must be enclosed in a fire-resistive structure
B. Combustible members must be treated with fire-resistive coatings.
C. No combustible structural members may penetrate a fire wall.
D. This type penetration is only allowed through walls rated less than 2 hours. - ANSWER-C. No
combustible structural members may penetrate a fire wall.
,When are either automatic or self-closing fire doors required?
A. When the facility is not sprinklered
B. In fire walls rated at 2 hours or more
C. When the doors are located in fire walls
D. In health care and public assembly occupancies - ANSWER-C. When the doors are located in fire walls
Under what conditions are ducts for heating, ventilation, and air-conditioning (HVAC) systems required
to be equipped with fire and smoke dampers?
A. When a duct penetrates a fire wall, regardless of the fire-resistance rating
B. When the duct penetrates a fire wall with a 2 hour or greater fire-resistance rating
C. If building is greater than three stories and not fire-resistive or noncombustible construction
D. In healthcare or public assembly occupancies with a rating occupancy load of over 20 persons -
ANSWER-B. When the duct penetrates a fire wall with a 2 hour or greater fire-resistance rating
Which of the following items is prohibited by codes?
A. Breaching the party wall for any reason
B. Installing a non-fire rated door in a party wall
C. Attaching any exterior structure to the party wall
D. Mounting combustible decorations on the interior of a party wall - ANSWER-A. Breaching the party
wall for any reason
When constructing fire partitions and barriers in fire-resistive structures, which of the following is a
common method used?
A. Using 1/2 inch (13 mm) fire-rated gypsum board applied to both sides of 2 1/2 inch (65 mm) steel
studs
B. Using concrete block with 1/2 inch (13 mm) fire-rated gypsum board applied to both sides
C. Using 5/8 inch (40 mm) fire-rated gypsum board applied to both sides of 2 inch by 4 inch (50 mm by
100 mm) lumber - ANSWER-A. Using 1/2 inch (13 mm) fire-rated gypsum board applied to both sides of
2 1/2 inch (65 mm) steel studs
,What is the design function of a curtain wall?
A. To provide fire separation between major interior areas
B. To seperate interior spaces from other interior spaces
C. To seperate the interior environment from the exterior environment
D. To provide fire separation around elevators and other vertical shafts - ANSWER-C. To seperate the
interior environment from the exterior environment
Which of the following is the primary use of fire-rated movable partitions?
A. To separate processes in industrial occupancies
B. To separate dissimilar areas within a single storage facility
C. To temporarily separate different functions within a building
D. To break rooms into multiple meeting spaces in convention halls - ANSWER-C. To temporarily
separate different functions within a building
From a fire protection perspective, what is the most important factor about trusses?
A. Trusses have a proven record of fire safety and are allowed by code for all applications.
B. Trusses are typically protected by insulation and thus do not pose a danger to fire crews.
C. Trusses use less material and are lighter than a comparable beam or joist for an equal span.
D. Trusses are stronger and will withstand more thermal stress than traditional structures. - ANSWER-C.
Trusses use less material and are lighter than a comparable beam or joist for an equal span.
When considering the flame resistance of wood flooring, which of the following statements is MOST
accurate?
A. Insist that the flooring materials be top-coated with an approved fire-retardant material as part of the
finish
B. Verify with the builder than the finishing material on the floowing will be non-combustible after
drying
C. Ensure that the manufacturer has had the flooring tested and that it has a rating of less than 100
D. Consult the manufacturer before accepting wood flooring where flame spread is an important factor -
ANSWER-D. Consult the manufacturer before accepting wood flooring where flame spread is an
important factor
, When considering steel as a building material, which of the following is important to remember? A.
Steel is very strong and presents few problems in fire protection.
B. The thinner the steel, the quicker it can be affected by heat.
C. Protected steel is only slightly better that unprotected steel.
D. Steel is the only way to achieve fire-resistive or noncombustible buildings. - ANSWER-B. The thinner
the steel, the quicker it can be affected by heat.
Which of the following are considered excellent building materials because of their fire resistance?
A. Steel and wood
B. Concrete and masonry
C. Steel and brick
D. Glass and masonry - ANSWER-B. Concrete and masonry
If a vertical penetration of a floor is designed into a building, what do codes require for enclosing that
penetration?
A. The penetration must be enclosed in a fire-resistive enclosure.
B The penetration is required to be enclosed with a 4-hour wall.
C. The penetration perimeter must be protected by a sprinkler system.
D. The penetration must be enclosed only above the second floor. - ANSWER-A. The penetration must be
enclosed in a fire-resistive enclosure.
When the space above a ceiling is designed as a return-air plenum, which of the following must the
inspector ensure?
A. The space above the ceiling is protected by the sprinkler system
B. The enclosure for the ceiling is constructed with a 2 hour rating
C. Wires, ducts, pipes, and other materials are noncombustible or rated for plenum use
D. Adequate provisions are made for venting smoke from a fire to the outside - ANSWER-C. Wires, ducts,
pipes, and other materials are noncombustible or rated for plenum use
When are stairs required to be protected or enclosed?
BANKACTUAL EXAM 500 QUESTIONS AND CORRECT
DETAILED ANSWERS (100% VERIFIED ANSWERS)
|AGRADE
The ultimate goal of any fire and life safety inspection program is to: A.
identify building code violations.
B. avoid the majority of uncontrolled fires.
C. ensure building owners comply with the permit process.
D. establish a process of preplan inspections in jurisdictions. - ANSWER-B. avoid the majority of
uncontrolled fires.
Building codes typically allow a reduction in the hourly rating of the fire walls when the building:
A. utilizes compartmentalization
B. is equipped with sprinkler systems.
C. is built using fire-resistive construction
D. is built using non-combustible construction. - ANSWER-B. is equipped with sprinkler systems
How must steel that has been incorporated into a fire wall be protected in steel-frame buildings? A.
There is no requirement for protection beyond natural qualities.
B. It is required to be enclosed within a fire-rated structure.
C. It must be protected with spray-on insulation or other barriers.
D. It must provide the same degree of fire resistance as the fire wall. - ANSWER-D. It must provide the
same degree of fire resistance as the fire wall.
What special treatments are required when a combustible structural member penetrates through a fire
wall?
A. They must be enclosed in a fire-resistive structure
B. Combustible members must be treated with fire-resistive coatings.
C. No combustible structural members may penetrate a fire wall.
D. This type penetration is only allowed through walls rated less than 2 hours. - ANSWER-C. No
combustible structural members may penetrate a fire wall.
,When are either automatic or self-closing fire doors required?
A. When the facility is not sprinklered
B. In fire walls rated at 2 hours or more
C. When the doors are located in fire walls
D. In health care and public assembly occupancies - ANSWER-C. When the doors are located in fire walls
Under what conditions are ducts for heating, ventilation, and air-conditioning (HVAC) systems required
to be equipped with fire and smoke dampers?
A. When a duct penetrates a fire wall, regardless of the fire-resistance rating
B. When the duct penetrates a fire wall with a 2 hour or greater fire-resistance rating
C. If building is greater than three stories and not fire-resistive or noncombustible construction
D. In healthcare or public assembly occupancies with a rating occupancy load of over 20 persons -
ANSWER-B. When the duct penetrates a fire wall with a 2 hour or greater fire-resistance rating
Which of the following items is prohibited by codes?
A. Breaching the party wall for any reason
B. Installing a non-fire rated door in a party wall
C. Attaching any exterior structure to the party wall
D. Mounting combustible decorations on the interior of a party wall - ANSWER-A. Breaching the party
wall for any reason
When constructing fire partitions and barriers in fire-resistive structures, which of the following is a
common method used?
A. Using 1/2 inch (13 mm) fire-rated gypsum board applied to both sides of 2 1/2 inch (65 mm) steel
studs
B. Using concrete block with 1/2 inch (13 mm) fire-rated gypsum board applied to both sides
C. Using 5/8 inch (40 mm) fire-rated gypsum board applied to both sides of 2 inch by 4 inch (50 mm by
100 mm) lumber - ANSWER-A. Using 1/2 inch (13 mm) fire-rated gypsum board applied to both sides of
2 1/2 inch (65 mm) steel studs
,What is the design function of a curtain wall?
A. To provide fire separation between major interior areas
B. To seperate interior spaces from other interior spaces
C. To seperate the interior environment from the exterior environment
D. To provide fire separation around elevators and other vertical shafts - ANSWER-C. To seperate the
interior environment from the exterior environment
Which of the following is the primary use of fire-rated movable partitions?
A. To separate processes in industrial occupancies
B. To separate dissimilar areas within a single storage facility
C. To temporarily separate different functions within a building
D. To break rooms into multiple meeting spaces in convention halls - ANSWER-C. To temporarily
separate different functions within a building
From a fire protection perspective, what is the most important factor about trusses?
A. Trusses have a proven record of fire safety and are allowed by code for all applications.
B. Trusses are typically protected by insulation and thus do not pose a danger to fire crews.
C. Trusses use less material and are lighter than a comparable beam or joist for an equal span.
D. Trusses are stronger and will withstand more thermal stress than traditional structures. - ANSWER-C.
Trusses use less material and are lighter than a comparable beam or joist for an equal span.
When considering the flame resistance of wood flooring, which of the following statements is MOST
accurate?
A. Insist that the flooring materials be top-coated with an approved fire-retardant material as part of the
finish
B. Verify with the builder than the finishing material on the floowing will be non-combustible after
drying
C. Ensure that the manufacturer has had the flooring tested and that it has a rating of less than 100
D. Consult the manufacturer before accepting wood flooring where flame spread is an important factor -
ANSWER-D. Consult the manufacturer before accepting wood flooring where flame spread is an
important factor
, When considering steel as a building material, which of the following is important to remember? A.
Steel is very strong and presents few problems in fire protection.
B. The thinner the steel, the quicker it can be affected by heat.
C. Protected steel is only slightly better that unprotected steel.
D. Steel is the only way to achieve fire-resistive or noncombustible buildings. - ANSWER-B. The thinner
the steel, the quicker it can be affected by heat.
Which of the following are considered excellent building materials because of their fire resistance?
A. Steel and wood
B. Concrete and masonry
C. Steel and brick
D. Glass and masonry - ANSWER-B. Concrete and masonry
If a vertical penetration of a floor is designed into a building, what do codes require for enclosing that
penetration?
A. The penetration must be enclosed in a fire-resistive enclosure.
B The penetration is required to be enclosed with a 4-hour wall.
C. The penetration perimeter must be protected by a sprinkler system.
D. The penetration must be enclosed only above the second floor. - ANSWER-A. The penetration must be
enclosed in a fire-resistive enclosure.
When the space above a ceiling is designed as a return-air plenum, which of the following must the
inspector ensure?
A. The space above the ceiling is protected by the sprinkler system
B. The enclosure for the ceiling is constructed with a 2 hour rating
C. Wires, ducts, pipes, and other materials are noncombustible or rated for plenum use
D. Adequate provisions are made for venting smoke from a fire to the outside - ANSWER-C. Wires, ducts,
pipes, and other materials are noncombustible or rated for plenum use
When are stairs required to be protected or enclosed?