NFPA 70E PRACTICE BANK WITH FULLY VERIFIED ANSWERS – 100% ACCURATE QUESTIONS TO ENSURE A PASS GUARANTEE

Puntuación
-
Vendido
-
Páginas
24
Grado
A+
Subido en
18-04-2025
Escrito en
2024/2025

NFPA 70E PRACTICE BANK WITH FULLY VERIFIED ANSWERS – 100% ACCURATE QUESTIONS TO ENSURE A PASS GUARANTEE....

Institución
NFPA 70E
Grado
NFPA 70E










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NFPA 70E
Grado
NFPA 70E

Información del documento

Subido en
18 de abril de 2025
Número de páginas
24
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NFPA 70E PRACTICE BANK WITH FULLY
VERIFIED ANSWERS – 100% ACCURATE
QUESTIONS TO ENSURE A PASS
GUARANTEE




200 QUESTIONS AND ANSWERS




Question 1

What is the primary purpose of NFPA 70E? Answer: To provide a practical
safe working area for employees relative to the hazards arising from the use of
electricity.

Question 2

What does an "electrically safe work condition" mean? Answer: A state in
which an electrical conductor or circuit part has been disconnected,
locked/tagged out, tested to verify the absence of voltage, and, if necessary,
temporarily grounded.

Question 3

What are the two types of electrical hazards defined in NFPA 70E? Answer:
Shock hazard and arc flash hazard.

Question 4

What is the shock protection boundary where unqualified persons may not cross
without qualified escort? Answer: Limited Approach Boundary.

Question 5

What document must be completed before work within the Limited Approach
Boundary or Arc Flash Boundary? Answer: An Energized Electrical Work
Permit (unless exemptions apply).

,Question 6

What is the purpose of an arc flash risk assessment? Answer: To identify arc
flash hazards, estimate the likelihood of occurrence and potential severity of
injury, and determine if additional protective measures are required.

Question 7

Which of the following is NOT one of the approach boundaries for shock
protection? Answer: Flash Protection Boundary (the three shock protection
boundaries are Limited Approach, Restricted Approach, and Prohibited
Approach).

Question 8

At what voltage level does NFPA 70E consider equipment to be "high voltage"?
Answer: Over 1000 volts.

Question 9

What does PPE stand for in electrical safety? Answer: Personal Protective
Equipment.

Question 10

Which of the following is NOT a justified condition for working on energized
equipment according to NFPA 70E? Answer: To save time or money on a
project.

Question 11

How often must employees who face a risk of electrical hazard receive
electrical safety training? Answer: At intervals not to exceed 3 years.

Question 12

What is the minimum arc rating for protective clothing when working on
equipment with an incident energy of 10 cal/cm²? Answer: Greater than 10
cal/cm² (typically would require PPE Category 3 or higher).

Question 13

Which of the following is NOT a typical component of host and contract
employer responsibilities? Answer: The host employer is solely responsible for

, all electrical accidents (incorrect - responsibilities are shared and defined for
both parties).

Question 14

What is an "arc flash boundary"? Answer: The distance from a prospective arc
source within which a person could receive a second-degree burn if an electrical
arc flash were to occur.

Question 15

What method must be used to verify that a circuit is de-energized before work
begins? Answer: Testing the circuit with an adequately rated test instrument.

Would you like more questions, or would you like me to focus on a specific
aspect of NFPA 70E?

Question 16

What is an "incident energy analysis"? Answer: A component of an arc flash
risk assessment that determines the incident energy exposure of the worker for
specific equipment.

Question 17

What does LOTO stand for in electrical safety procedures? Answer:
Lockout/Tagout.

Question 18

Which NFPA 70E category requires a minimum arc rating of 25 cal/cm²?
Answer: PPE Category 4.

Question 19

Under NFPA 70E, electrical equipment operating at 50 volts or more must be:
Answer: De-energized before work is performed, unless de-energizing
introduces additional hazards or is infeasible.

Question 20

The ________ Approach Boundary is the distance within which only qualified
persons may work. Answer: Restricted.

Question 21
$18.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
luzlinkuz Chamberlain University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1427
Miembro desde
4 año
Número de seguidores
849
Documentos
27650
Última venta
2 días hace

3.7

303 reseñas

5
131
4
61
3
54
2
17
1
40

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes