UST INSPECTOR EXAM NEWEST ACTUAL EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) | ALREADY GRADED A+

Puntuación
-
Vendido
-
Páginas
56
Grado
A+
Subido en
03-04-2025
Escrito en
2024/2025

UST INSPECTOR EXAM NEWEST ACTUAL EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) | ALREADY GRADED A+

Institución
UST INSPECTOR
Grado
UST INSPECTOR











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
UST INSPECTOR
Grado
UST INSPECTOR

Información del documento

Subido en
3 de abril de 2025
Número de páginas
56
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

UST INSPECTOR EXAM NEWEST
ACTUAL EXAM QUESTIONS AND
CORRECT ANSWERS (VERIFIED
ANSWERS) | ALREADY GRADED A+

Which of the following is not a consideration when
entering a confined space?
A) Confined entry/exit
B) Oxygen content
C) Flammable gas/vapor
D) Water table level Correct Answer D) Water table level

Title 8: 5157 permit-required confined spaces
3. Before an employee enters the space, the internal
atmosphere shall be tested, with a calibrated direct
reading instrument, for the following conditions in the order
given:
A. oxygen content
B. Flammable gases and vapors, and
C. potential toxic air containment

According to PEI 1200, at what distance should an air
compressor be located when conducting Secondary
Containment Testing?
A) 15 feet
B) 20 feet
C) 45 feet
D) 30 feet Correct Answer B) 20 feet

,PEI 1200
"If a portable air compressor is used, it should be located
at least 20 feet away from the venturi-eductor or outside
any Class I, Division 1 area." (pg. 9 & 17)

What substance is used as a test fluid when using the
Hydrostatic Test Method?
A) Diesel
B) Gasoline
C) Water
D) E85 Correct Answer C) Water

PEI 1200
"WARNING: Do not use fuels such as gasoline, E85, or
diesel as a test fluid because they present a serious fire
and safety hazard..." (pg. 14)

PEI things to note Correct Answer 500(9): fueling incident
response
500(10.4): inspecting inside of dispenser cabinet after a
fueling system incident
500(2.16, 2.8, 2.9): shear valve placement in the
dispenser island
In definitions: Class 1 Division 1 (area under normal
operation has fumes, equipment is functioning properly, ,
electrical failure can cause fire) , Class 1 division
II(container failure of a normally closed system creates a
fire or explosion hazard .
1200: What to note before secondary containment tank
testing. I believe it was tank ullage. (Tank volume,
groundwater level 4.24)

,1200(7.2): can ball valves be the primary overfill
protection? (Not recommended)

By December 31, 2003, all UST systems must have the
following installed EXCEPT:
a)Spill bucket with 5-gallon capacity
b)Secondary containment piping on vent lines
c)Striker plate
d)Under-dispenser containment Correct Answer b)
Secondary containment piping on vent lines
CCR Title 23: Sec 2635(b)(2), 2631(c), 2666(e)(1)

UST system includes the following component(s):
a) tank only
b) piping only
c) tank, associated piping and ancillary equipment
d) tank, piping, dispensing units, and nozzles Correct
Answer (c) tank, associated piping and ancillary
equipment
HS&C, sec 25281(z)

Monthly monitoring records must be kept on file for ___.
a) 5 years
b) 3 years
c) 6.5 years
d) the life of the UST system Correct Answer (b) 3 years
CCR Title 23, sec 2712 (b)

The Designated Operator shall renew the ICC certification:

a) every 24 months

, b) every 36 months
c) via correspondence course
d) there is no renewal required Correct Answer (a) every
24 months
CCR Title 23, sec 2715 (b)

Which of the following underground storage tank openings
need to be sealed during temporary closure?
a) fill and vent locations
b) fill and access locations
c) access and vent locations
d) vent locations only Correct Answer (b) fill and access
locations
CCR Title 23, sec 2671 (a)(4)

A tank system under temporary closure must be inspected
at what interval?

a) monthly
b) every 2 months
c) every 3 months
d) every 6 months Correct Answer (c) every 3 months
CCR Title 23, sec 2671 (c)

All existing USTs shall be retrofitted with Under-dispenser
containment by
a) January 1, 1984
b) December 22, 1998
c) July 1, 2003
d) December 31, 2003 Correct Answer (d) December 31,
2003
$24.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TUTORWAC Johns Hopkins University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
334
Miembro desde
2 año
Número de seguidores
114
Documentos
3529
Última venta
1 semana hace
TUTORWAC

BEST HOMEWORK HELP AND TUTORING ON YOUR QUIZZES AND EXAMS WITH GUARANTEE OF EXCELLENT GRADES

4.1

52 reseñas

5
31
4
8
3
6
2
3
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes