100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

C 10 Electrical Exam Part V & VI & VII Exam Solved Questions With Revised Correct Detailed Answers Brand New Version !!

Puntuación
-
Vendido
-
Páginas
88
Grado
A+
Subido en
28-10-2024
Escrito en
2024/2025

C 10 Electrical Exam Part V & VI & VII Exam Solved Questions With Revised Correct Detailed Answers Brand New Version !! 1. Which of the following is an acceptable marking method for the grounding conductor on a grounding-type receptacle? A) A white-colored round-headed terminal. B) A tag with 1/4-inch high letters. C) An orange dot. d) D) A green-colored hexagonal headed or shaped terminal screw or nut. - ANSWER NEC Section Section 406.9(B) permits Answer D as one of the several approved methods of identifying a grounding-type receptacle. 2. What type fixture wires are required when the wires are mounted on chains supporting a lighting fixture? A)Solid conductors only. B)Stranded conductors only. C)Either solid or stranded. D)Compressed aluminum conductors only. - ANSWER B NEC Section 410.28(E) requires stranded conductors to be used for wiring on fixture chains and on other movable or flexible parts. 3. Flexible cords used to connect cord-connected showcase lighting must be of what type? A)Light-duty type. B)Extra hard-service type. C)Hard-service type. D)None of the above. - ANSWER C NEC Section 410.29(A) requires flexible cords used to connect showcase lighting to be of the hard-service type. 4. Normally, lighting fixtures must not be used as a raceway for circuit conductors execept when _____. A)the fixtures are designed for end-to-end assembly to form a continuous raceway or fixtures connected together by recognized wiring methods shall be permitted to carry through conductors of a two-wire or multiwire branch circuit supplying the fixture B)the fixtures are listed as a raceway C)one additional two-wire branch circuit separately supplying one or more of the connected fixtures described in Answer B shall be permitted to be carried through the fixture D)All the above. - ANSWER D NEC Section 410.32 allows all three conditions in Answers A, B, and C. 5. Branch circuit conductors installed within 3 inches of an electric-discharge fixture ballast must have insulation with a tempeture rating no lower than _____. A)90 degrees C (194 degrees F) B)30 degrees C (86 degrees F) C)150 degrees C (302 degrees F) D)40 degrees C (104 degrees F) - ANSWER The Correct Answer Is A NEC Section 410.33 requires such conductors to be rated for a tempeture not lower than 90 degrees C which includes such types as RHH, THW, THHN, FEPB, SA, and XHHW insulations. 6. Electric-discharge lighting fixtures must be plainly marked with their electrical rating. This marking must include the voltage, frequency, and _____. A)wattage B)current rating C)resistance D)All the above. - ANSWER The Correct Answer Is B NEC Sections 410.35(A) and (B) require the voltage and frequency to be listed along with the current rating of the unit, including the ballast, transformer, or autotransformer. 7. What type of lining must be provided in wiring compartments of all non metallic lighting fixtures? A)Glass B)Plastic C)Porcelain D)Metal - ANSWER The Correct Answer Is D NEC Section 410.37 requires all non-metallic lighting fixtures not made entirely of non-combustible material to have their wiring compartments lined with metal. 8. Which of the following types of lampholders are approved for installation in wet or damp locations? A)Weatherproof B)Mogul-base type C)Intermediate base type with explosion-proof fittings. D)Candelabra type - ANSWER The Correct Answer Is A NEC Section 410.49 requires fixtures to be of the weatherproof type when installed in wet or damp locations.

Mostrar más Leer menos
Institución
C 10
Grado
C 10











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
C 10
Grado
C 10

Información del documento

Subido en
28 de octubre de 2024
Número de páginas
88
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

C 10 Electrical Exam Part V & VI & VII
Exam Solved Questions With Revised
Correct
Detailed Answers
Brand New Version !!

1. Which of the following is an acceptable marking method for the grounding
conductor on a grounding-type receptacle?
A) A white-colored round-headed terminal.
B) A tag with 1/4-inch high letters.
C) An orange dot.
D) A green-colored hexagonal headed or shaped terminal screw or nut. -
ANSWER d)
NEC Section Section 406.9(B) permits Answer D as one of the several approved
methods of identifying a grounding-type receptacle.


2. What type fixture wires are required when the wires are mounted on chains
supporting a lighting fixture?
A)Solid conductors only.
B)Stranded conductors only.
C)Either solid or stranded.

D)Compressed aluminum conductors only. - ANSWER B

,NEC Section 410.28(E) requires stranded conductors to be used for wiring on
fixture chains and on other movable or flexible parts.


3. Flexible cords used to connect cord-connected showcase lighting must be of
what type?
A)Light-duty type.
B)Extra hard-service type.
C)Hard-service type.

D)None of the above. - ANSWER C
NEC Section 410.29(A) requires flexible cords used to connect showcase lighting
to be of the hard-service type.


4. Normally, lighting fixtures must not be used as a raceway for circuit conductors
execept when _____.
A)the fixtures are designed for end-to-end assembly to form a continuous
raceway or fixtures connected together by recognized wiring methods shall be
permitted to carry through conductors of a two-wire or multiwire branch circuit
supplying the fixture
B)the fixtures are listed as a raceway
C)one additional two-wire branch circuit separately supplying one or more of the
connected fixtures described in Answer B shall be permitted to be carried through
the fixture

D)All the above. - ANSWER D
NEC Section 410.32 allows all three conditions in Answers A, B, and C.


5. Branch circuit conductors installed within 3 inches of an electric-discharge
fixture ballast must have insulation with a tempeture rating no lower than _____.

,A)90 degrees C (194 degrees F)
B)30 degrees C (86 degrees F)
C)150 degrees C (302 degrees F)

D)40 degrees C (104 degrees F) - ANSWER The Correct Answer Is A
NEC Section 410.33 requires such conductors to be rated for a tempeture not
lower than 90 degrees C which includes such types as RHH, THW, THHN, FEPB, SA,
and XHHW insulations.


6. Electric-discharge lighting fixtures must be plainly marked with their electrical
rating. This marking must include the voltage, frequency, and _____.
A)wattage
B)current rating
C)resistance

D)All the above. - ANSWER The Correct Answer Is B
NEC Sections 410.35(A) and (B) require the voltage and frequency to be listed
along with the current rating of the unit, including the ballast, transformer, or
autotransformer.


7. What type of lining must be provided in wiring compartments of all non-
metallic lighting fixtures?
A)Glass
B)Plastic
C)Porcelain

D)Metal - ANSWER The Correct Answer Is D
NEC Section 410.37 requires all non-metallic lighting fixtures not made entirely of
non-combustible material to have their wiring compartments lined with metal.

, 8. Which of the following types of lampholders are approved for installation in
wet or damp locations?
A)Weatherproof
B)Mogul-base type
C)Intermediate base type with explosion-proof fittings.

D)Candelabra type - ANSWER The Correct Answer Is A
NEC Section 410.49 requires fixtures to be of the weatherproof type when
installed in wet or damp locations.


9. Isolated ground receptacles shall be identified by _____.
A)an orange triangle
B)a green dot
C)a permanent seal

D)standard lugs - ANSWER The Correct Answer Is A
NEC Section 406.2(D) requires such receptacles to have an orange triangle located
on the face of the receptacle.


10. What is the maximum incandescent lamp wattage that may be used on
medium base lampholders?
A)100 watts
B)200 watts
C)300 watts

D)400 watts - ANSWER The Correct Answer Is C
Incandescent lamps for general use on lighting branch circuits that are equipped
with medium base lampholders must not exceed 300 watts. NEC Section 410.53.
$17.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EWLindy Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
706
Miembro desde
3 año
Número de seguidores
431
Documentos
7370
Última venta
10 horas hace
EN.CY.CLO.PE.DI.A

Hello, I am Passionate about education with over 7yrs teaching.. Welcome to my page...my documents are 100% guaranteed to help you Ace in your career path, Combining a wide view of career courses education Journey Proffesionaly. Will be very helpful for those students who want to make a change in nursing field and other close courses . Please go through the sets description appropriately before any purchase. The *Sets have been used years in years out by serious students to exercise, revise and even pass through their examinations. All revisions done by Expert Minds. This Gives You No Excuse To Leave A Bad Review. Thankyou . SUCCESS IN YOUR EDUCATION JOURNEY !! GOODLUCK IN YOUR STUDIES.

Lee mas Leer menos
3.8

106 reseñas

5
54
4
13
3
16
2
6
1
17

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes