100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

CT TEST REVIEW (TEST Q'S AND A'S FOR CT REGISTRY PREP. THIS IS FROM THE BOOK "COMPUTED TOMOGRAPHY FOR TECHNOLOGISTS: EXAM REVIEW" BY LOIS E ROMANS. PUBLISHED BY WOLTERS KLUWER, LIPPINCOTT WILLIAMS AND WILKINS.)

Puntuación
-
Vendido
-
Páginas
43
Grado
A+
Subido en
18-08-2024
Escrito en
2024/2025

CT TEST REVIEW (TEST Q'S AND A'S FOR CT REGISTRY PREP. THIS IS FROM THE BOOK "COMPUTED TOMOGRAPHY FOR TECHNOLOGISTS: EXAM REVIEW" BY LOIS E ROMANS. PUBLISHED BY WOLTERS KLUWER, LIPPINCOTT WILLIAMS AND WILKINS.) Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination? A. Topogram B. Scout C. Scanogram D. Spiral - Correct Answer D. Spiral The ability of a system to differentiate, on the image, objects with similar densities is known as: A. High contrast resolution B. Low contrast resolution C. Spatial resolution D. Temporal resolution - Correct Answer B. Low contrast resolution Each two dimensional square of data that make up the CT image is called a: A. Pixel B. Voxel C. Matrix D. Fragment - Correct Answer A. Pixel How many pixels are contained in a 1,024 matrix image? A. 1,024 B. 2,048 C. 262,144 D. 1,048,576 - Correct Answer D. 1,048,576 Beam attenuation can be defined as: A. The phenomenon by which artifacts result when lower energy photons are preferentially absorbed, leaving only higher-intensity photons to strike the detector array.

Mostrar más Leer menos
Institución
CT REGISTRY
Grado
CT REGISTRY











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
CT REGISTRY
Grado
CT REGISTRY

Información del documento

Subido en
18 de agosto de 2024
Número de páginas
43
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

CT TEST REVIEW (TEST Q'S AND A'S FOR CT
REGISTRY PREP. THIS IS FROM THE BOOK
"COMPUTED TOMOGRAPHY FOR
TECHNOLOGISTS: EXAM REVIEW" BY LOIS E
ROMANS. PUBLISHED BY WOLTERS KLUWER,
LIPPINCOTT WILLIAMS AND WILKINS.)
Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination?

A. Topogram

B. Scout

C. Scanogram

D. Spiral - Correct Answer D. Spiral



The ability of a system to differentiate, on the image, objects with similar densities is known as:

A. High contrast resolution

B. Low contrast resolution

C. Spatial resolution

D. Temporal resolution - Correct Answer B. Low contrast resolution



Each two dimensional square of data that make up the CT image is called a:

A. Pixel

B. Voxel

C. Matrix

D. Fragment - Correct Answer A. Pixel



How many pixels are contained in a 1,024 matrix image? A. 1,024

B. 2,048

C. 262,144

D. 1,048,576 - Correct Answer D. 1,048,576



Beam attenuation can be defined as:

A. The phenomenon by which artifacts result when lower energy photons are preferentially
absorbed, leaving only higher-intensity photons to strike the detector array.

,B. Xray energy that is produced from bombarding a substance with fast moving electrons.

C. The ability of the detector to capture transmitted photons and change them to electronic signals.

D. The phenomenon by which an xray beam passing through a structure is decreased in intensity or
amount because of absorption and interaction with matter. - Correct Answer D. The phenomenon by
which an xray beam passing through a structure is decreased in intensity or amount because of
absorption and interaction with matter.



Which of the following is a low attenuation structure:

A. Iodine filled aorta

B. Rib

C. Trachea

D. Calcified arteries - Correct Answer C. Trachea



An object is slightly less dense than water. What is the expected hounsfield measurement?

A. -940

B. -10

C. 50

D. 850 - Correct Answer B. -10



Why does the administration of iodinated contrast media result in an enhanced image?

A. Iodinated contrast material increases the ability of the enhanced structure to attenuate the xray
beam.

B. Iodinated contrast material decreases the average photon energy of the xray beam; therefore
more photons are absorbed by the patient.

C. The administration of contrast material results in a smaller pixel, thereby increasing spatial
resolution, which results in an enhanced image.

D. - Correct Answer A. Iodinated contrast material increases the ability of the enhanced structure to
attenuate the xray beam.



The xray beam sources for CT produce xray energy that is polychromatic. This means:

A. When viewed by the naked eye, the beam exhibits many different colors.

B. It produce, as a byproduct, a substance known as polychlorinated biphenyl.

C. Photons contained in the beam are all of the same wavelength.

,D. The beam comprises photons with varying energies. - Correct Answer D. The beam comprises
photons with varying energies.



An object that appears on the image but is not present in the object scanned is called a/n:

A. Artifact

B. Anomaly

C. Shadow

D. Ghost - Correct Answer A. Artifact



Which is an advantage of filtering the xray beam?

A. Filtering reduces the anode heat load

B. A filtered beam produces images with substantially less quantum mottle

C. Filtering the beam prevents energy from being converted to heat, therefore 100% of the energy is
converted to xrays.

D. Filtering reduces the radiation dose to the patient. - Correct Answer D. Filtering reduces the
radiation dose to the patient



Scan thickness is primarily important for the part it plays in:

A. Noise reduction

B. The contrast scale

C. Detector aperture opening

D. Volume averaging - Correct Answer D. Volume averaging



You are working with the radiologist to establish examination protocols for your department. Which
of the following is a logical consideration when determining an appropriate slice thickness for studies
of the internal auditory canal?

A. Because the auditory ossicles are quite small, a thin slice will be necessary to reduce the chance
that volume averaging will obscure their appearance on the image.

B. The appropriate slice thickness will vary considerably from patient to patient. Therefore, each
technologist should be free to adjust the slice thickness as he or she deems necessary for the
particular patient.

C. A slice thickness of 5 to 7mm is adequate because the structures of interest are not particularly
small and the examination is most often ordered as a screening study for asymptomatic patients.

, D. The thickest slice available should be used to reduce the radiation dose to the corneas. - Correct
Answer A. Because the auditory ossicles are quite small, a thin slice will be necessary to reduce the
chance that volume averaging will obscure their appearance on the image.



How many CT numbers are assigned to each pixel in the image matrix?

A. One half the number of all values recorded from the detector array

B. One

C. The number of HU per pixel is one tenth the display field of view

D. Two values for a 256 matrix; 4 values for a 512 matrix - Correct Answer B. One



Which is another name for raw data?

A. Image data

B. Scan data

C. Reconstructed data

D. Displayed data - Correct Answer B. Scan data



When in the anatomic position, the arms are:

A. raised above the head, palms backwards

B. crossed over the chest, palms on opposite shoulders

C. down by the sides, palms forward

D. by the sides, elbows bent, palms backward and resting on hips - Correct Answer C. down by the
sides, palms forward



Which of the following components is NOT housed within the gantry?

A. Three phase generator

B. High-frequency generator

C. Slip rings

D. Xenon gas detectors - Correct Answer A. Three phase generator



The power capacity of the generator is listed in:

A. milliamperes (mA)

B. thousand heat units (KHU)
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Winfred West Virgina University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
763
Miembro desde
3 año
Número de seguidores
473
Documentos
7414
Última venta
1 día hace
StudySmart

Revising without a good structure can be so frustrating but with StudySmart you are able to get revision questions, summary notes and exams to help you pass with flying colors

3.9

158 reseñas

5
78
4
28
3
27
2
8
1
17

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes