100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

BPI: Building Science Fundamentals Exam | Questions & Answers (100 %Score) Latest Updated 2024/2025 Comprehensive Questions A+ Graded Answers | With Expert Solutions

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
04-08-2024
Escrito en
2024/2025

BPI: Building Science Fundamentals Exam | Questions & Answers (100 %Score) Latest Updated 2024/2025 Comprehensive Questions A+ Graded Answers | With Expert Solutions

Institución
BPI
Grado
BPI









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
BPI
Grado
BPI

Información del documento

Subido en
4 de agosto de 2024
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

BPI: Building Science Fundamentals Exam | Questions & Answers (100 %Score) Latest
Updated 2024/2025 Comprehensive Questions A+ Graded Answers | With Expert Solutions




CFM - cubic feet per minute

CFM50 - cubic feet per minute at 50 pascals of pressure

ACHn - natural air changes per hour

ACH50 - air changes per hour at 50 pascals of pressure

How to calculate ACH50 - CFM50 x 60 / volume of home

AFUE - Annual Fuel Utilization Efficiency. The efficiency of a boiler or furnace. It is the
ratio of annual heat output of the furnace or boiler compared to the total annual fossil
fuel energy consumed by a furnace or boiler

SSE - Steady State Efficiency. This is the heat extracted from the fuel and delivered to
the heat exchanger. The ratio of Btu input to useful or recoverable heat.

SEER - Seasonal Energy Efficiency Ratio. The efficiency measurement for a central air
conditioner or heat pump (during cooling season). The ratio of cooling capacity (BTUH
or BTUs per hour of heat removed) to watts.

EER - Energy Efficiency Ratio. The efficiency measurement for a central air conditioner,
heat pump AND room air conditioners (during cooling season). It is the ratio of cooling
capacity (BTUH) to watts of power.

HSPF - Heating Seasonal Performance Factor. A rating for heat pumps Ratio of BTUs
of energy used to watt-hr of electricity consumed.

Testing for SSE - High CO2 = good High O2 = bad

Watt - Unit of power (j/s)

Ton of Refrigeration - a measure of the amount of heat removed. 1 ton of refrigeration =
12,000 BTU/hr = 3,517 watts

BTU - unit of energy. 1 BTU is equal to the energy needed to raise 1 lb of water 1
degree F.

Therm - 6.Therm - a unit of heat equal to 100,000 BTUs

Decatherm - one million BTU's or 10 therms

, Energy - What is delivered

Power - rate at which it is delivered, Power = work/time

Effective Leakage Area - is a measurement of the air tightness of a home that is
expressed as an area (in2) to help the homeowner better visualize and quantify leakage
in a home.

ELA example - take your measured CFM50 and divide it by 10. Your answer is the
equivalent size hole in square inches. So a CFM50 measured at 1,440, would have an
ELA equal to 144 sq inches or, 1 sq ft.

R-Value - the measure of a materials thermal resistance in units of ft²·°F·h/Btu.
Insulation properties are described in terms of R-values. The higher the R-value, the
greater the thermal resistance.

U-Value - the overall heat transfer coefficient. U-values are a measure of conductance a
material. It tell us how much heat conducts through a 1 sq ft area in 1 hr when there is a
1 degree F temperature difference.

Understanding U-value - It tells us how much heat conducts through a 1 sq ft area in 1
hr when there is a 1 degree F temperature difference. The smaller the U-value, the
better the object is at reducing heat transfer.

Relationship between U and R values - 1 / R-value = U-value

1 / U-value = R-value

Difference between U and R values - R-values can be added together, U-values cannot

Assumptions for weighted R value calculations - •16-IOC (inch-on-center) studs account
for 20-25% of the wall area OR 75% of the wall area is an open cavity

•24-IOC studs account for 15-20% of the wall area

Everything rolls down hill - High temp to low, high pressure to low, high moisture to low

Radiation - Radiant energy flies through space through electromagnetic waves from one
object to another.

What happens to radiant heat? - All radiant heat is either absorbed, reflected or
transmitted.
$13.48
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Favorgrades Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
752
Miembro desde
3 año
Número de seguidores
374
Documentos
29901
Última venta
21 horas hace
Favorgrades Emporium

3.7

183 reseñas

5
76
4
41
3
31
2
11
1
24

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes