Under Patient Testing, Touch the end of the Test Strip to the blood drop, maintaining
contact until the 10-second countdown begins and a beep sounds.Alternatively, apply a
drop of well-mixed EDTA whole blood from a tube or syringe. - COrreCT aNSWer-False
Under Quality Control and Patient Testing Procedure, If the screen enters sleep mode
and darkens at any time during testing, tap the screen to illuminate it before continuing.
- COrreCT aNSWer-True
For Quality Control, place a drop of Control Solution from the bottle at the end of the
test strip until the solution is drawn into the well of the test strip, maintaining contact until
the 6-second countdown begins and a beep sounds. - COrreCT aNSWer-True
The meters does not have a QC Lockout function that prevents patient testing unless
the QC is performed successfully by a qualified operator. - COrreCT aNSWer-False
What are acceptable samples, sample sizes, and analysis time for NOVA Biomedical
StatStrip Glucometer? - COrreCT aNSWer-Capillary whole blood (finger stick), venous
whole blood, arterial whole blood, neonate heel stick, and neonate arterial whole blood
specimens, 1.2 ul, analysis time at 6 seconds
Alternate site testing (earlobe, forearm) is NOT allowed - COrreCT aNSWer-True
COMPeTeNCy aNd POiNT Of Care (iNTerNaL MediCiNe CLiNiC) eXaM
NeWeST 2026 WiTH COMPLeTe QueSTiONS aNd COrreCT deTaiLed
aNSWerS (Verified aNSWerS) |aLready Graded a+||braNd NeW
VerSiON!!
Under Patient Testing, Touch the end of the Test Strip to the blood drop, maintaining
contact until the 10-second countdown begins and a beep sounds.Alternatively, apply a
drop of well-mixed EDTA whole blood from a tube or syringe. - COrreCT aNSWer-False
Under Quality Control and Patient Testing Procedure, If the screen enters sleep mode
and darkens at any time during testing, tap the screen to illuminate it before continuing.
- COrreCT aNSWer-True
For Quality Control, place a drop of Control Solution from the bottle at the end of the
test strip until the solution is drawn into the well of the test strip, maintaining contact until
the 6-second countdown begins and a beep sounds. - COrreCT aNSWer-True
The meters does not have a QC Lockout function that prevents patient testing unless
the QC is performed successfully by a qualified operator. - COrreCT aNSWer-False
What are acceptable samples, sample sizes, and analysis time for NOVA Biomedical
StatStrip Glucometer? - COrreCT aNSWer-Capillary whole blood (finger stick), venous
whole blood, arterial whole blood, neonate heel stick, and neonate arterial whole blood
specimens, 1.2 ul, analysis time at 6 seconds
Alternate site testing (earlobe, forearm) is NOT allowed - COrreCT aNSWer-True