Unsafe roof access would indicate sweeping _______________ - Correct answer-
Sweeping from bellow is best
NFPA 211 states when you sweep a chimney you must perform what level of
inspection? - Correct answer-Level I
Required clearances for a wood stove would best be found in? - Correct answer-
Manufacturer's instruction or data plate on the appliance
Unlisted wood burning stoves require _________ inches of floor protection on all
sides? - Correct answer-18
The cross section area of a flue can not exceed _______ times the flue collar for a
wood stove vented into an exterior chimney. - Correct answer-2
A connector pipe six feet long must rise at least _____ from the appliance to the
chimney. - Correct answer-1.5 inches