COA 2025 FALL/WINTER ACTUAL PRACTICE TEST QUESTIONS WITH ACCURATE
SOLUTIONS
When recording chief complaint the assistant should include
only facts stated by patient
The concentration of a chemical in a pharmaceutical solution is also called the...
tonicity
Which drug is used for applanation tonometry?
Proparicane
The ophthalmologist instructs that a patient is to receive drops b.i.d; the assistant should
instruct the patient to take the drops...
twice a day
The use of topical steroids may induce which of the following? A) Retinal detachment, B)
Cataracts, C) Keratoconus, D) Hyphema
Cataracts
,Protaglandins drops can cause...
increased iris pigmentation, eyelash growth, and conjunctival hyperemia
What tool is a series of red cylinders to assess phoria?
Maddox rod
Which test uses prisms to center corneal reflex?
Krimsky
Which item is not a classification of fixation?
A.Central, B. Steady, C. Maintained, D. Primary
D. Primary
Which item is not a designation of a version?
A.Levoversion, B.Sursumversion, C.Dextoversion, D.Intraversion
D. Intraversion
,A granulated inflammation of the eyelid that may be removed surgically if it does not
subside is a....
chalazion
Probing of the tear duct may be useful treatment for patients with...
epiphora
close examination of the lids, lashes, cornea, and lens can be accomplished with
biomicroscopy
in the snellen acuity recording chart the reading 20/100 the number "100" represents
distance in feet at which a normal eye can see a particular line on the chart
If pinhole acuity test is for to improve a patients poor visual acuity the patient potentially
has
a refractive error
, Jaeger notations, snellen M units and distance equivalence are various units of measuring
near acuity
Having a patient follow a finger in the 6 cardinal positions of gaze is a method of evaluating
extraocular muscle function
The prism and alternate cover test is used to evaluate
measure deviation in a misaligned eye
When pupils are of unequal size it is called...
anisocoria
Which test compares the direct and consensual responses to the pupil? A) Swinging
Flashlight, B)Worth four-dot, C) pinhole disk, or D) Cover- Uncover
Swinging Flashlight
A disadvantage of chemical-based contact lens care systems is...A)irritation, B)simplicity
of use, C) poor disinfection, D) low replacement rate
irritation
SOLUTIONS
When recording chief complaint the assistant should include
only facts stated by patient
The concentration of a chemical in a pharmaceutical solution is also called the...
tonicity
Which drug is used for applanation tonometry?
Proparicane
The ophthalmologist instructs that a patient is to receive drops b.i.d; the assistant should
instruct the patient to take the drops...
twice a day
The use of topical steroids may induce which of the following? A) Retinal detachment, B)
Cataracts, C) Keratoconus, D) Hyphema
Cataracts
,Protaglandins drops can cause...
increased iris pigmentation, eyelash growth, and conjunctival hyperemia
What tool is a series of red cylinders to assess phoria?
Maddox rod
Which test uses prisms to center corneal reflex?
Krimsky
Which item is not a classification of fixation?
A.Central, B. Steady, C. Maintained, D. Primary
D. Primary
Which item is not a designation of a version?
A.Levoversion, B.Sursumversion, C.Dextoversion, D.Intraversion
D. Intraversion
,A granulated inflammation of the eyelid that may be removed surgically if it does not
subside is a....
chalazion
Probing of the tear duct may be useful treatment for patients with...
epiphora
close examination of the lids, lashes, cornea, and lens can be accomplished with
biomicroscopy
in the snellen acuity recording chart the reading 20/100 the number "100" represents
distance in feet at which a normal eye can see a particular line on the chart
If pinhole acuity test is for to improve a patients poor visual acuity the patient potentially
has
a refractive error
, Jaeger notations, snellen M units and distance equivalence are various units of measuring
near acuity
Having a patient follow a finger in the 6 cardinal positions of gaze is a method of evaluating
extraocular muscle function
The prism and alternate cover test is used to evaluate
measure deviation in a misaligned eye
When pupils are of unequal size it is called...
anisocoria
Which test compares the direct and consensual responses to the pupil? A) Swinging
Flashlight, B)Worth four-dot, C) pinhole disk, or D) Cover- Uncover
Swinging Flashlight
A disadvantage of chemical-based contact lens care systems is...A)irritation, B)simplicity
of use, C) poor disinfection, D) low replacement rate
irritation