100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4,6 TrustPilot
logo-home
Exam (elaborations)

Engine Fire Protection Systems Exam Questions With Complete Solutions (Updated)

Rating
-
Sold
-
Pages
3
Grade
A+
Uploaded on
03-12-2025
Written in
2025/2026

Engine Fire Protection Systems Exam Questions With Complete Solutions (Updated) In a thermal switch type fire detection system, heat sensitive switches are placed in _______________ with each other, and in _______________ with the flight deck indicator lights. A. parallel; series B. series; parallel C. series; series - Answer- A Which of the following are features of an ideal fire detection system? 1. illuminates a light on the flight deck which indicates the location of the fire 2. sets off an audible alarm 3. low number or no false alarms 4. resettable when the fire is out 5. minimum electrical current requirements A. 1, 3, 5 B. 2, 3, 4, and 5 C. 1, 2, 3, 4, and 5 - Answer- C What is the operating principle of the spot detector sensor in a fire detection system? A. Resistant core material that prevents current flow at normal temperatures. B. fi conventional thermocouple that produces a current flow. C. A bimetallic thermal switch that closes when heated to a high temperature. - Answer- C Which of the following fire detection systems measure temperature rise compared to a reference temperature? A. thermocouple B. thermal switch C. lindberg continuous element - Answer- A Optical fire detection systems A. can be infrared or ultraviolet. B. must be used out of the way of direct sunlight. C. give a false alarm if not disarmed before an incandescent light strikes the sensor. - Answer- A A fire detection system operates on the principle of a buildup of gas pressure within a tube proportional to temperature. Which of the following systems does this statement define? A. kidde continuous-loop system B. lindberg continuous-element system C. thermal switch system - Answer- B What is the principle of operation of the continuous loop fire detection system sensor? A. fuse material which melts at high temperatures B. core resistance material which prevents current flow at normal temperatures C. a bimetallic thermo-switch which closes when heated to a high temperature - Answer- B Which of the following is the safest fire- extinguishing agent to use from a standpoint of toxicity and corrosion hazards? A. dibromodiflouromethane (Halon 1202) B. bromochlorodiflouromethane (Halon 1211) C. bromotriflouromethane (Halon 1301) - Answer- C How is the fire extinguishing agent distributed in the engine section? A. spray nozzles and fluid pump B. nitrogen pressure and slinger rings C. spray nozzles and perforated tubing - Answer- C In a fixed fire-extinguishing system, there are two small lines running from the system and exiting overboard. The line exit ports are covered with a blowout type indicator disc. Which of the following statements is true? A. When the red indicator is missing, it indicates the fire- extinguishing system has been normally discharged. B. When the yellow indicator disc is missing, it indicates the fire-extinguishing system has been normally discharged. C. When the green indicator disc is missing, it indicates the fire-extinguishing system has had a thermal discharge. - Answer- B A common visual check of fire detection elements includes A. the contact points in the control box. B. cracked or broken sections. C. the color of missing blowout disks. - Answer- B If a continuous-loop fire detection system is giving a false alarm, how can it be determined if the problem is in the control unit or in the sensing loop? A. by disconnecting the loop from the control box and observing if the false alarm stops B. by connecting a voltmeter across the connected loop terminals C. by resetting the warning lights and timing the interval until the next false alarm - Answer- A

Show more Read less
Institution
Engine Fire Protection Systems
Course
Engine Fire Protection Systems








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Engine Fire Protection Systems
Course
Engine Fire Protection Systems

Document information

Uploaded on
December 3, 2025
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Engine Fire Protection Systems Exam
Questions With Complete Solutions
(Updated)
In a thermal switch type fire detection system, heat sensitive switches are placed in
_______________ with each other, and in _______________ with the flight deck
indicator lights.
A. parallel; series
B. series; parallel
C. series; series - Answer- A

Which of the following are features of an ideal fire detection system?
1. illuminates a light on the flight deck which indicates the location of the fire
2. sets off an audible alarm
3. low number or no false alarms
4. resettable when the fire is out
5. minimum electrical current requirements
A. 1, 3, 5
B. 2, 3, 4, and 5
C. 1, 2, 3, 4, and 5 - Answer- C

What is the operating principle of the spot detector sensor in a fire detection system?
A. Resistant core material that prevents current flow at normal temperatures.
B. fi conventional thermocouple that produces a current flow.
C. A bimetallic thermal switch that closes when heated to a high temperature. - Answer-
C

Which of the following fire detection systems measure temperature rise compared to a
reference temperature?
A. thermocouple
B. thermal switch
C. lindberg continuous element - Answer- A

Optical fire detection systems
A. can be infrared or ultraviolet.
B. must be used out of the way of direct sunlight.
C. give a false alarm if not disarmed before an incandescent light strikes the sensor. -
Answer- A

A fire detection system operates on the principle of a buildup of gas pressure within a
tube proportional to temperature. Which of the following systems does this statement
define?
A. kidde continuous-loop system

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuviaascorers University of Washington
Follow You need to be logged in order to follow users or courses
Sold
346
Member since
2 year
Number of followers
185
Documents
10100
Last sold
4 days ago
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Read more Read less
3,8

64 reviews

5
30
4
11
3
11
2
2
1
10

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions