100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Surgical Technology Certification

Rating
-
Sold
-
Pages
58
Grade
A+
Uploaded on
10-11-2025
Written in
2025/2026

Surgical Technology Certification

Institution
Surgical Tech
Course
Surgical tech











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Surgical tech
Course
Surgical tech

Document information

Uploaded on
November 10, 2025
Number of pages
58
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Surgical Technology Certification
2025/2026
EXAM ACTUAL EXAM QUESTIONS AND
WELL ELABORATED ANSWERS WITH
(100% VERIFIED SOLUTIONS) LATEST
UPDATES | ALREADY GRADED A+




How often must a biological control test be run? a.
every day
b. every cycle
c. once a week
d. once a month -
ANSWER>>ANSWER: A [pg. 163]


The Bowie-Dick test for pre-vacuum sterilizers checks for which of the
following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket
d. that the sterilizer is ready to process instruments -
ANSWER>>ANSWER: B

,lot control numbers should be placed on each package sterilized and on
the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
d. cover of the patient's chart - ANSWER>>ANSWER: B


How long is a 3M Attest 1292 steam biological indicator incubated before
the reading is recorded? a. 12 hours
b. 36 hours
c. 24 hours
d. 48 hours - ANSWER>>ANSWER:
C 12 hours - rapid ; 24 hours - not
rapid


During a vascular procedure a vessel is ligated. The surgeon states that
she will repair the vessel after bleeding is controlled. Which needle type
would she most likely require to complete this task? a. control release
needle
b. French eyed needle
c. tapered needle
d. cutting needle - ANSWER>>ANSWER: C

When steam sterilizing biological indicators, how long are they incubated
before the reading is recorded? a. 48 hours
b. 24 hours
c. 12 hours
d. 72 hours - ANSWER>>ANSWER: B

,An OB-GYN surgeon has posted a laparoscopic partial hysterectomy and
has informed the surgical team that the ovaries are remaining. However,
the fallopian tubes will require ligation involoving the tubes being clipped
and cauterized. Which of the following instruments should the surgical
technologist open
a. a Flishie and hemoclip applier
b. a Flishie and Kleppinger
c. a Kleppinger and harmonic scalpel
d. a harmonic scalpel and hemoclip applier - ANSWER>>ANSWER: D


Which of the following instruments can be decontaminated in the
washersterilizer?
a. colonoscope
b. power drill
c. laser coated instrument set
d. phaco instrument set - ANSWER>>ANSWER: C


The patient has undergone cardiac bypass surgery. Protamine has been
administered and the surgeon is preparing to close the sternotomy.

Bleeding is a postoperative concern. Which of the following systems should
the surgical technologist anticipate the surgeon will use? a. Hemovac
b. Jackson Pratt
c. Pleur-Evac
d. Penrose - ANSWER>>ANSWER: C

, A patient presents to the operating room for irrigation and debridement of a
wound caused by penetrating trauma. The surgeon states that the wound
will heal by secondary intention. Which of the following dressing types
should the surgical technologist ask the circulator for? a. ABD
b. bolsters
c. bio-occlusive strips
d. Steri-strips - ANSWER>>ANSWER: A


During an abdominoperineal repair, which of the following is the most
appropriate stapler to assemble and hand to the surgeon to perform an
anastomosis between the proximal and distal ends of the colon? a. TA
b. GIA
c. EEA
d. LDS - ANSWER>>ANSWER: C


A pressure dressing is most likely applied over a a.
TURP
b. skin graft
c. fractured femur EX fix
d. cataract surgery - ANSWER>>ANSWER: B


During an open laparotomy the surgeon drops a Poole suction tip before
irrigating. It is the only suction tip available and it has to be re-sterilized to
be used later in the procedure. Which of the following types of
sterilization should the surgical technologist use? a. ethylene oxide
b. gravity displacement
c. pre vac

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AndrewBenson Johns Hopkins University
Follow You need to be logged in order to follow users or courses
Sold
19
Member since
10 months
Number of followers
0
Documents
1945
Last sold
6 days ago

3,0

2 reviews

5
1
4
0
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions