Fuel gas or oxygen containers in storage must be separated from any combustible
materials by a minimum distance of - correct answer 20 feet.
Most fires are the result of - correct answer Sparks.
Sparks and pieces of hot metal are the source of ignition in about______ of fires in
industrial occupancies. - correct answer 60.
Under no circumstances can hot work be performed within _____ feet of flammable or
explosive materials. - correct answer 35.
If torch operation is to be discontinued for a period of ___________, the torch valve must
be closed and the gas supply to the torch must be completely shut. - correct answer
One hour or more.
A torch should be ignited by using a - correct answer Friction device.
Why should oil or grease not be used near oxygen? - correct answer It might cause an
explosion.
How long is a site permanent specific permit to store flammable gases valid for? -
correct answer 30 days
How many Fire Guards are required on a job site that has 3 torches in operation? -
correct answer One per torch and additional one stationed on the floor below.
Portable LPG containers greater than ______ must not be stored in residential
occupancies. - correct answer 16.4 oz.
An oxygen cylinder may store gas at pressure up to - correct answer 2200 psi.
A Responsible Person is one who is - correct answer trained in the fire safety hazards
associated with hot work, and in the necessary and appropriate measures to minimize
those hazards, who is designated by the owner of a premises to authorize the
performance of hot work at the premises.
A designated Hot Work area must be at least_______ feet away from combustible
materials. - correct answer 35.
, FDNYC G60 Practice Exam (Latest Update
) Questions and 100% Correct
Answers [Grade A]– Lehman College
For all Hot Work, inspections must be completed_______ after completion of torch
operations. - correct answer 30 minutes.
A minimum ___________ rating Fire Extinguisher must be readily accessible within
________ of the hot work location for torch operations. - correct answer 2-A:20-B:C, 30
feet.
For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must
be readily accessible within ________. - correct answer 3-A: 40-B:C, 30 feet.
Empty compressed gas cylinders - correct answer Should be handled in the same
manner as full ones.
Panic Bar - correct answer A device fitted on the inside of a door that would allow a
person to push against a door to open it.
A type of valve typically used in sprinkler systems - correct answer OS & Y Valve-
Outside Screw and Yoke Valve.
Fire Drill - correct answer A training exercise by which building occupants are
familiarized with and/ or practice the procedures for the safe, orderly and expeditious
in-building relocation, partial evacuation or evacuation, as applicable to the occupancy
or building type, in accordance with the fire safety and evacuation plan.
shall not be considered a fire - correct answer flame used in any lawful, properly
operating device, equipment or system or other controlled setting.
Fire Watch - correct answer A temporary measure intended to ensure continuous and
systematic surveillance of a building or portion thereof by one or more qualified
individuals for the purposes of identifying and controlling fire hazards, detecting early
signs of fire, raising an alarm of fire and notifying the department.
Hot Work - correct answer Cutting, welding, thermit welding, brazing, soldering,
grinding, thermal spraying, thawing pipe, cad welding, installation of torch-applied
system, or any other similar operation or activity.