REVIEWED CORRECT DETAILED
ANSWERS
When installing any type of access fitting onto a sealed system
a. The system must be pressurized with dry nitrogen before Leak testing can be
attempted
b. The fitting need not be leak tested until the total repair is completed
c. is not necessary to leak test and access fitting
d. The fitting should be leak tested before proceeding with recovery - Answer-d. The
fitting should be leak tested before proceeding with recovery
When R-410A is recovered from an appliance, it;
a. should be recovered into a recovery vessel that is clearly marked to ensure that
mixing of refrigerants does not occur
b. need not be recovered since R-410A is not one of the refrigerants covered by the
Clean Air Act
c. can be mixed with R-123a but not with R-22 during the process p
d. can be mixed with either R-32 or R-125a during the recovery process, since R-410A
is a mixture of those two refrigerants - Answer-a. should be recovered into a recovery
vessel that is clearly marked to ensure that mixing of refrigerants does not occur
What type of certification is required for persons recovering CFCs HCFCs or HFCs
during maintenance service or repair of small appliances
a. technician who has passed the core exam
b. type 1 technician or universal technician
c. type 3 technician
d. type 2 technician - Answer-b. type 1 technician or universal technician
Before beginning a refrigerant recovery procedure it is always necessary to;
a. disconnect the appliance from its power source
b. remove the appliance to an outdoor location
c. know the type of refrigerant that is in the system
d. allow the appliance to stabilize that room temperature - Answer-c. know the type of
refrigerant that is in the system
A passive system dependent recovery process for small appliances
a. can only be performed on a system with an operating compressor
, b. captures refrigerant in a non-pressurized container
c. must use a pressure relief device when recovering refrigerant
d. still uses a pump to recover refrigerant - Answer-b. captures refrigerant in a non-
pressurized container
It is generally recommended that piercing type valves be used on which of the following
tubing materials
a. copper and aluminum
b. steel and brass
c. aluminum and steel
d. copper and steel - Answer-a. copper and aluminum
Which recovery equipment maintenance practice should be performed on a regular
basis
a. check amperage draw of vacuum pump
b. check amperage draw of recovery device
c. check recovery device for refrigerant leaks
d. check vacuum pump for any leaks - Answer-c. Check recovery device for refrigerant
leaks
a standard vacuum pump design specifically for evacuation and dehydration can
a. be used alone as a system dependent (passive) recovery device
b. be used alone as a substitute for any recovery device
c. never be used as a recovery device in combination with a pressurized container
d. be used alone as a self-contained (active) recovery device - Answer-c. never be used
as a recovery device in combination with a pressurized container
When is it essential to take measures to help release trapped CFC HCFC or HFC
refrigerant from the compressor oil during refrigerant recovery
a. when the refrigerant system has a low side leak
b. when using passive recovery devices on small appliances with non-operating
compressors
c. when using system dependent active recovery devices
d. when using self-contained recovery devices - Answer-b. when using passive recovery
devices on small appliances with non-operating compressors
For which of the following refrigeration systems/appliances would it be permissible to
use a passive recovery device for a refrigerant recovery of CFCs HCFCs and HFCs
a. a domestic refrigerator
b. a single compressor, large commercial walk-in freezer
c. a reciprocating liquid chiller
d. a centrifugal air conditioner - Answer-a. a domestic refrigerator
What is the maximum normal charge of HCFC or HFC refrigerant in an appliance that is
allowed to use system dependent recovery equipment
a. 50 pounds