100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4,6 TrustPilot
logo-home
Exam (elaborations)

IRC Test Paper with Right Answers

Rating
-
Sold
-
Pages
18
Grade
A+
Uploaded on
29-01-2025
Written in
2024/2025

Above-ground service-entrance cables subject to physical damage shall be protected by Schedule ________ PVC conduit.- Sch. 80 PVC Interior metal water piping located more than _______ feet from the point of entrance to the building shall not be used as part of the grounding electrode system. - 5 ft. Rod and pipe electrodes shall be not less than ______ feet in length - 8 ft. Bonding shall be provided where necessary to ensure electrical _________ and the capacity to conduct safely any fault current likely to be imposed. - continuity All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to the grounding electrodes shall be ____________. - accessible Where a branch circuit or a feeder supplies a continuous load it shall have an ampacity of _______ percent of the continuous load.- 125% The rating of any one cord-and-plug-connected utilization equipment shall not exceed _______ percent of the branch-circuit ampere rating. - 80% Branch circuit ratings for space-heating and water-heating appliances shall be considered ___________ loads. - continuous A minimum of ___________ 20-ampere-rated branch circuits shall be provided to serve all wall and floor receptacle outlets located in the kitchen, pantry, breakfast area and dining area or similar area of a dwelling. - two A minimum of _________ 20-ampere-rated branch circuit shall be provided for receptacles located in the laundry area and shall serve only receptacle outlets in the laundry area. - one

Show more Read less
Institution
IRC
Course
IRC










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
IRC
Course
IRC

Document information

Uploaded on
January 29, 2025
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

IRC Test Paper with Right Answers
Above-ground service-entrance cables subject to physical damage shall be
protected by Schedule ________ PVC conduit.- ✅✅ Sch. 80 PVC

Interior metal water piping located more than _______ feet from the point of
entrance to the building shall not be used as part of the grounding electrode system.
- ✅✅ 5 ft.

Rod and pipe electrodes shall be not less than ______ feet in length - ✅✅ 8 ft.

Bonding shall be provided where necessary to ensure electrical _________ and
the capacity to conduct safely any fault current likely to be imposed. - ✅✅
continuity

All mechanical elements used to terminate a grounding electrode conductor or
bonding jumper to the grounding electrodes shall be ____________. - ✅✅
accessible

Where a branch circuit or a feeder supplies a continuous load it shall have an
ampacity of _______ percent of the continuous load.- ✅✅ 125%

The rating of any one cord-and-plug-connected utilization equipment shall not
exceed _______ percent of the branch-circuit ampere rating. - ✅✅ 80%

Branch circuit ratings for space-heating and water-heating appliances shall be
considered ___________ loads. - ✅✅ continuous

A minimum of ___________ 20-ampere-rated branch circuits shall be provided to
serve all wall and floor receptacle outlets located in the kitchen, pantry, breakfast
area and dining area or similar area of a dwelling. - ✅✅ two

A minimum of _________ 20-ampere-rated branch circuit shall be provided for
receptacles located in the laundry area and shall serve only receptacle outlets in the
laundry area. - ✅✅ one

,A minimum of ________ 20-ampere branch circuit shall be provided to supply the
bathroom receptacle outlet(s). Such circuits shall have no other outlets. - ✅✅
one

Insulated conductors and cables exposed to direct rays of the sun shall be listed and
labeled as _________________. - ✅✅ sunlight resistant

Where raceways are installed in wet locations above grade, the interior of such
raceways shall be considered to be a _____________ location. - ✅✅ wet

Underground service laterals that are not encased in concrete and that are buried 18
inches or more below grade shall have their location identified by a ___________
____________ - ✅✅ warning ribbon

Receptacles shall be installed so that no point along the floor line in any wall space
is more than _______ feet, measured horizontally, from an outlet in the space. -
✅✅ 6 ft.

An application for a permit for any proposed work shall be deemed to have been
abandoned ______ days after the date of filing. - ✅✅ 180 days

Final inspection shall be made after the permitted work is __________ and prior to
_____________ - ✅✅ complete, occupancy

Signifies access the requires the removal of an access panel or similar removable
obstruction - ✅✅ Accessible
(Readily accessible signifies access without the necessity for removing a panel or
similar obstruction.)

Hot water is water at a temperature greater than or equal to _____ F - ✅✅ 110 F

What is the minimum uniformly distributed live load for habitable attics and attics
served with fixed stairs? - ✅✅ 30 pounds per square foot

Exterior walls of dwellings and accessory buildings with a fire separation distance
less than ______ feet shall have not less than a one-hour fire-resistive rating with
exposure from both sides. - ✅✅ 5 ft.

The minimum openable area to the outdoors shall be ________ percent of the floor
being ventilated - ✅✅ 4%

, Bathrooms ... Shall be provided with an aggregate glazing area in windows of not
less than _______ square feet, one-half of which must be openable - ✅✅ 3 sq.
Ft.

Dwelling units shall be provided with heating facilities capable of maintaining a
minimum room temperature of ______ F - ✅✅ 68 F

Every dwelling unit shall have at least one habitable room that shall have not less
than _______ square feet of gross area - ✅✅ 120 sq. Ft.

Other habitable rooms shall have a floor area of not less than _____ square feet -
✅✅ 70 sq. Ft.

Habitable rooms shall not be less than ____ feet in any horizontal dimension. -
✅✅ 7 ft.

Habitable space, hallways, corridors, bathrooms, toilet rooms, laundry rooms and
portions of basements containing these spaces shall have a ceiling height of not
less than _______ feet. - ✅✅ 7 ft.

For rooms with sloped ceilings, at least _______ percent of the required floor area
of the room must have a ceiling height of not less than 7 feet - ✅✅ 50%

Portions of basements that do not contain habitable space, hallways, bathrooms,
toilet rooms and laundry rooms shall have a ceiling height of not less than ___ feet
and _____ inches. - ✅✅ 6 ft., 8 in.

Every dwelling unit shall be provided with a water closet, lavatory, and a
_________ or ________. - ✅✅ bathtub or shower

Each dwelling unit shall be provided with a kitchen area and every kitchen area
shall be provided with a ________. - ✅✅ sink

Showers and bathtubs with installed shower heads shall be finished with a
nonabsorbent surface that shall extend to a height of not less than ______ feet
above the floor - ✅✅ 6 ft.

Glazing in all fixed and operable panels of swinging, sliding and bifold doors shall
be considered a ________________. - ✅✅ hazardous location
R220,82
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Document also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
kharowl Stanford University
Follow You need to be logged in order to follow users or courses
Sold
14
Member since
2 year
Number of followers
7
Documents
1509
Last sold
3 weeks ago
The Scholar's Depot: Where Knowledge Meets Opportunity

Imagine a digital marketplace buzzing with academic vitality—Kharowl. This knowledgeable entrepreneur curates a treasure trove of meticulously crafted exam materials, sharing a passion for aiding fellow scholars in their academic journeys. Their dedication to excellence shines through every document, fostering a community where knowledge is not just sold but shared.

3,0

2 reviews

5
1
4
0
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions