Massachusetts Journeyman Pipefitter Exam
(Heating, Cooling) PJ-01
1/2" - - Sight Glass Minimum Connection
3/4" - - Low Water Cut-off Draw Minimum Connection
1" - - Water Column Minimum Connection
3/4" - - Control Manifold Minimum Connection
1/4" - - Sight Glass Drain Minimum Connection
1" - - Bottom Blow-Off Minimum Connection
2 1/2" - - Bottom Blow-Off Maximum Connection
2 1/2" - - Surface Blow-Down Maximum Connection
3" - - Threaded Safety Valve Maximum Connection
4 1/2" - - Flanged Safety Valve Maximum Connection
Up to 2" - - Steam Stop Valve Non-Indicating
1/2" - - Take-off for Control Line Minimum Connection
3" - - Socket Welded Fitting Maximum Size
, Massachusetts Journeyman Pipefitter Exam
(Heating, Cooling) PJ-01
2 1/2" and over - - Hangers Must be Adjusted Over
1/4" - - Minimum Size Syphon Non-Ferrous
350 psi - - Malleable Iron Maximum PSI
250 - - Cast Iron Maximum PSI
250 Degrees - - ASME V Maximum Water Temperature Heating Boiler
500 Square Feet of Heating Surface (2 means of water feed) - - When do you need 2
or more heating safety's?
Over 400 psi (cast iron sectional/MAWP 30psi) - - When do you need 2 sight glasses?
30 - - The ASME code for heating boilers says that an ASME code, Section VIII
expansion tank is required on a hot water boiler when the boiler pressure exceeds what
pressure (psig)?
Steel - - When the pressure exceeds 100 psi, the boiler blow-off fittings shall
be_____________?
Not be restricted or reduced - - The discharge outlet of a safety valve must
________________________.
(Heating, Cooling) PJ-01
1/2" - - Sight Glass Minimum Connection
3/4" - - Low Water Cut-off Draw Minimum Connection
1" - - Water Column Minimum Connection
3/4" - - Control Manifold Minimum Connection
1/4" - - Sight Glass Drain Minimum Connection
1" - - Bottom Blow-Off Minimum Connection
2 1/2" - - Bottom Blow-Off Maximum Connection
2 1/2" - - Surface Blow-Down Maximum Connection
3" - - Threaded Safety Valve Maximum Connection
4 1/2" - - Flanged Safety Valve Maximum Connection
Up to 2" - - Steam Stop Valve Non-Indicating
1/2" - - Take-off for Control Line Minimum Connection
3" - - Socket Welded Fitting Maximum Size
, Massachusetts Journeyman Pipefitter Exam
(Heating, Cooling) PJ-01
2 1/2" and over - - Hangers Must be Adjusted Over
1/4" - - Minimum Size Syphon Non-Ferrous
350 psi - - Malleable Iron Maximum PSI
250 - - Cast Iron Maximum PSI
250 Degrees - - ASME V Maximum Water Temperature Heating Boiler
500 Square Feet of Heating Surface (2 means of water feed) - - When do you need 2
or more heating safety's?
Over 400 psi (cast iron sectional/MAWP 30psi) - - When do you need 2 sight glasses?
30 - - The ASME code for heating boilers says that an ASME code, Section VIII
expansion tank is required on a hot water boiler when the boiler pressure exceeds what
pressure (psig)?
Steel - - When the pressure exceeds 100 psi, the boiler blow-off fittings shall
be_____________?
Not be restricted or reduced - - The discharge outlet of a safety valve must
________________________.