100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Building Inspector exam Questions With 100% Correct Answers

Rating
-
Sold
-
Pages
12
Grade
A+
Uploaded on
05-09-2024
Written in
2024/2025

Building Inspector exam Questions With 100% Correct Answers -outside each separate sleeping area in the immediate vicinity of the bedrooms. - Answer-Smoke alarms are required to be installed in which of the following locations? [R314.3] /.1 1/4 inches - Answer-Cold-formed steel framing supporting gypsum board and gypsum panel products shall be not less than xxx in wide in the least dimension. [R702.3.3] /.1 unit vertical in 12 units horizontal - Answer-What is the max. slope permitted for a ramp serving an egress door? [R311.8.1] /.1/2in gyp board will be used as an interior wall covering and installed perpendicular to framing members at 16" o.c. What is the max. spacing of nails on center where adhesive is not used? - Answer-8 in Table R702.3.5 /.10' - Answer-Where located in Seismic Design Category B, braced wall panels shall begin a max. of ---- from the end of a braced wall line. [R602.10.2.2] /.12 - Answer-A ledger is used to connect a masonry wall and a wood floor system having floor joists spanning 16'. The building is in seismic design category B and the wind load is 25 psf. Half inch ledger bolt shall be located at the max. of ---- in center. [R606.11 (1)] /.14'-1" - Answer-Where 2 in by 10 in floor joists of #1 spruce pine fir are spaced at 16 O.C, what is the max. span when joists support a living room and a dead load of 20psf? [R502.3.1(2)] /.16 - Answer-Wood structural panel wall sheathing of 3/8 inch thick with a span rating of 24/0 in a wind exposure category C with an ultimate design wind speed of 115 mph will be used to resist wind pressures. What is the max. stud spacing permitted for this application? [R Table 602.3 (3)] /.16" O.C. - Answer-What is the max. stud spacing for 2x6 bearing wall studs supporting two floor and a roof ceiling assembly? [ Table R602.3(5)] /.18x24 - Answer-access openings to under floor spaces located in a floor must be a min. of (r 408.4) /.2 - Answer-A top landing is NOT required where a stairway of not more than ---- risers is located on the exterior side of the door, provided that the door does not swing over the stairway. [R311.3.2. Exception] /.20' - Answer-Ionization smoke alarms shall not be installed less than --- horizontally from a permanently installed cooking appliance. [R314.3.1] /.24 - Answer-Wood structural panel wall sheathing 7/16 inch thick with a span rating of 24/16 will be located in an area with an ultimate design wind speed of 135 mph and wind exposure category B. What is the max. wall stud spacing permitted? [R Table 602.3 (3)] /.24 inches - Answer-Ice barriers shall extend from the lowest edges of all roof surfaces to a point not less than ---- inside the exterior wall line of the building. [R905.1.2] /.3 - Answer-Min. headlap for slate shingles shall be ----inch for a 10:!2 roof slope. [Table 905.6.5] /.3:12 - Answer-Where the roof pitch is less than ----, the structural members that support rafters and ceiling joists (such as ridge beams, hips, and valleys) shall be designed as beams. [R802.4.4] /.3.5" - Answer-The min. thickness for a concrete slab on ground floor for a two family dwelling R506.1 /.3/8 - Answer-What is the min. permissible thickness for structural roof sheathing without edge support; with a live load of 30 psf; a total load of 40 psf; and rafters spaced 16" in. o.c? [Table503.2.1.1] /.4 3/8" - Answer-Guards at the open sides of stairways must not allow passage at a sphere ---- inches in diameter. [R312.1.3. Exception #2] /.4;8 - Answer-Wood structural panels 15/32 in. thick attached to wall framing with 15 Ga 1-3/4 in. long staples shall be fastened at a max. of ---- in. at the panel edges and ----in. at the intermediate supports. [R602.3.(2)]

Show more Read less
Institution
Building Inspector
Course
Building Inspector









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Building Inspector
Course
Building Inspector

Document information

Uploaded on
September 5, 2024
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

-outside each separate sleeping area in the immediate vicinity of the bedrooms. -
Answer-Smoke alarms are required to be installed in which of the following locations?
[R314.3]

/.1 1/4 inches - Answer-Cold-formed steel framing supporting gypsum board and
gypsum panel products shall be not less than xxx in wide in the least dimension.
[R702.3.3]

/.1 unit vertical in 12 units horizontal - Answer-What is the max. slope permitted for a
ramp serving an egress door?
[R311.8.1]

/.1/2in gyp board will be used as an interior wall covering and installed perpendicular to
framing members at 16" o.c. What is the max. spacing of nails on center where
adhesive is not used? - Answer-8 in

Table R702.3.5

/.10' - Answer-Where located in Seismic Design Category B, braced wall panels shall
begin a max. of ---- from the end of a braced wall line. [R602.10.2.2]

/.12 - Answer-A ledger is used to connect a masonry wall and a wood floor system
having floor joists spanning 16'. The building is in seismic design category B and the
wind load is 25 psf.

Half inch ledger bolt shall be located at the max. of ---- in center. [R606.11 (1)]

/.14'-1" - Answer-Where 2 in by 10 in floor joists of #1 spruce pine fir are spaced at 16
O.C, what is the max. span when joists support a living room and a dead load of 20psf?
[R502.3.1(2)]

/.16 - Answer-Wood structural panel wall sheathing of 3/8 inch thick with a span rating
of 24/0 in a wind exposure category C with an ultimate design wind speed of 115 mph
will be used to resist wind pressures.

What is the max. stud spacing permitted for this application?
[R Table 602.3 (3)]

/.16" O.C. - Answer-What is the max. stud spacing for 2x6 bearing wall studs supporting
two floor and a roof ceiling assembly? [ Table R602.3(5)]

, /.18x24 - Answer-access openings to under floor spaces located in a floor must be a
min. of (r 408.4)

/.2 - Answer-A top landing is NOT required where a stairway of not more than ---- risers
is located on the exterior side of the door, provided that the door does not swing over
the stairway.

[R311.3.2. Exception]

/.20' - Answer-Ionization smoke alarms shall not be installed less than --- horizontally
from a permanently installed cooking appliance. [R314.3.1]

/.24 - Answer-Wood structural panel wall sheathing 7/16 inch thick with a span rating of
24/16 will be located in an area with an ultimate design wind speed of 135 mph and
wind exposure category B. What is the max. wall stud spacing permitted?
[R Table 602.3 (3)]

/.24 inches - Answer-Ice barriers shall extend from the lowest edges of all roof surfaces
to a point not less than ---- inside the exterior wall line of the building.
[R905.1.2]

/.3 - Answer-Min. headlap for slate shingles shall be ----inch for a 10:!2 roof slope.
[Table 905.6.5]

/.3:12 - Answer-Where the roof pitch is less than ----, the structural members that
support rafters and ceiling joists (such as ridge beams, hips, and valleys) shall be
designed as beams.
[R802.4.4]

/.3.5" - Answer-The min. thickness for a concrete slab on ground floor for a two family
dwelling R506.1

/.3/8 - Answer-What is the min. permissible thickness for structural roof sheathing
without edge support; with a live load of 30 psf; a total load of 40 psf; and rafters spaced
16" in. o.c? [Table503.2.1.1]

/.4 3/8" - Answer-Guards at the open sides of stairways must not allow passage at a
sphere ---- inches in diameter.

[R312.1.3. Exception #2]

/.4;8 - Answer-Wood structural panels 15/32 in. thick attached to wall framing with 15
Ga 1-3/4 in. long staples shall be fastened at a max. of ---- in. at the panel edges and ---
-in. at the intermediate supports.
[R602.3.(2)]

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
kartelodoc Harvard University
Follow You need to be logged in order to follow users or courses
Sold
118
Member since
1 year
Number of followers
4
Documents
7814
Last sold
7 hours ago

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Read more Read less
3,2

22 reviews

5
7
4
1
3
7
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions