CORRECT Answers
True or False: The FireFighter may be installed next to a stand-alone battery-powered smoke
detector. - CORRECT ANSWER- False
True or False: When performing a full system test, you may bypass any open doors or
windows. - CORRECT ANSWER- False
When programming an SKEY1, you must Always...? - CORRECT ANSWER- Enable
emergency key
True or False: When running power to the TAKE-345, polarity does not apply. - CORRECT
ANSWER- False
When programming the emergency key for an SKEY1, which zone/sensor types are
recommended to use? - CORRECT ANSWER- Auxiliary and audible alarm
True or False: When installing an SMKT3, you must use the included screws and anchors -
CORRECT ANSWER- True
True or False: When installing the Fire Fighter, it is required to test the customer's existing
smoke detectors. - CORRECT ANSWER- T
When installing a DW21, where is the approved location for the sensor? - CORRECT
ANSWER- Btw 6 & 2 in from the floor
When installing a DW11 on a vinyl or metal frame, what should you primarily use to mount
the sensor? - CORRECT ANSWER- Double sided tape
Select all that apply: Which of the following materials can you use to group multiple ground
terminals in a Takeover module? - CORRECT ANSWER- Wire caps or B connectors/Beans
, What sensor are you not allowed to program using a translator? - CORRECT ANSWER-
Smoke detector
True or False: When installing the TAKE-345 you must always test the new 12v Battery
before using it. - CORRECT ANSWER- True
What is the output voltage of the transformer used to power the Smart Hub? - CORRECT
ANSWER- 12 VDC
What is the minimum distance for placement of a CO3 from the corners on a wall? -
CORRECT ANSWER- 12 in
True or False: The SMKT3 has only 2 functions: smoke and heat detection. - CORRECT
ANSWER- False
How would you program a CO3 if mounted on a hallway wall? - CORRECT ANSWER-
Loop 1, zone type 14
True or False: When installing a translator, you must program all of the existing sensors as
new equipment on the panel. - CORRECT ANSWER- false
When programming a DW11 that has been installed on a window, which zone/sensor type
should you use? - CORRECT ANSWER- 3
True or False: The DW21 sensor should always be installed in the door frame - CORRECT
ANSWER- True
What equipment is used on all metal door frames - CORRECT ANSWER- DW11
Which zone/sensor types are used when programming an SMKT3? - CORRECT ANSWER-
Type 9 smoke detection, type 8 freeze detection, type 9 heat detection
What is the correct height at which to install the PIR2? - CORRECT ANSWER- 7.5 ft