NICET Fire Alarm Level 1 Part Exam Questions And Revised Correct Answers What is an Addressable Device? - Answer -It is a fire alarm system component that possesses discreet identification. __________ Detector has a piping distribution network to the areas being protected. Air Sampling-Type detector uses a fan inside its housing to draw air. - Answer -3.3.66.1 Air sampling-type An _________ that transmits a signal indicating varying degrees of condition - Answer -3.3.132.1 Analog Initiating Device A __________ can transmit a signal that indicates on off condition only. - Answer -3.3.132.1 Conventional Initiating Device __________ is a feature that can reduce unwanted alarms. - Answer -3.3.16 Alarm verification Fire alarms from an auxiliary system are always received at: - Answer -Fire alarms from an auxiliary system are always received at the public fire service communication center. Auxiliary Fire Alarm System is connected to: - Answer -Auxiliary Fire Alarm System is connected to a municipal fire alarm system. Municipal fire alarm system - Answer -A public emergency alarm reporting system Auxiliary Fire Alarm System - Answer -A protected premises fire alarm system or other emergency system at the protected premises and the system used to connected the protected premises system to a public emergency alarm reporting system for transmitting an alarm to the communications center. You need to request NFPA to certify your installations. True? - Answer -Not true. The NFPA does not certify any installations. AHJ is responsible for approving installations. An AHJ is responsible for: - Answer -An Authority Having Jurisdiction is responsible for approving an installation. What is an Annunciator? - Answer -An Annunciator has multiple indicator lamps, alphanumeric displays... etc... to show status information of a circuits condition. A __________ Fire Alarm Box requires that you break a special element so to gain access to and operate the box. - Answer -A Breakglass Fire Alarm Box requires that you break a special element so to gain access to and operate the box. What does Compatibility Listed mean? - Answer -Compatibility Listed is a specific listing process that applies to TWO WIRE DEVICES only. Combination Detector - Answer -Combination Detector can respond to multiple fire phenomenon. Equipment is LISTED - Answer -The equipment is included in a list publish by an organization which is acceptable to the "AHJ" With a "non-restorable" initiating device: - Answer -the sensing element will be DESTROYED during the process of operation What is a pull station? - Answer -PULL STATION is a manually operated device which may be used to initiate an alarm signal. Describe NRTL: - Answer -It is the Nationally Recognized Testing Laboratory that is recognized by the OSHA as meeting the qualifications specified in the Code of Federal Regulations. CODE - Answer -Code are written rules that are adopted as law. What give the details on how the requirement of the code may be achieved? - Answer -STANDARDS give the details on how the requirement of the code may be achieved.
Written for
- Institution
- NICET Fire Alarm Level 1
- Course
- NICET Fire Alarm Level 1
Document information
- Uploaded on
- April 24, 2024
- Number of pages
- 7
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
nicet fire
-
nicet fire alarm level 1
-
nicet fire alarm level 1 part
-
nicet fire alarm level 1 part exam
-
exam questions and revised correct answers