100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Water distribution d1 and d2 good Exam Questions and Answers 100% Accurate

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
08-04-2024
Written in
2023/2024

Cross connection - ANSWER-A connection between a safe and an unsafe water supply is called a Is available for use without causing shortages during dry periods - ANSWER-Safe yield of a water source is the quantity of water which: Rate of flow of water - ANSWER-A Venturi tube increases the velocity and decreases the pressure as water flows through it. This type of tube is used to measure the: Underground strata of water - ANSWER-Aquifer is a type of 10 percent - ANSWER-In a well managed metered distribution system, unaccounted-for-water should not exceed 35 psi - ANSWER-According to AWWA guidelines, during a fire,water pressure should not drop below 20 psi. What is the AWWA recommended minimum water pressure in a distribution system, under normal flow conditions, excluding fire flow? Closed slowly to reduce surges - ANSWER-After using a hydrant, the hydrant should be: 15-20 ft - ANSWER-For a centrifugal pump in good condition, the practical suction lift is. Acidic - ANSWER-PH reading of 5.0 indicates the water sample is Ten drops per minute - ANSWER-When using a centrifugal pump, the packing glands around the shaft should be checked daily, water leakage from the packing gland should be approximately Horizontal 10 ft, vertical 1 ft - ANSWER-Water and sewer line are installed parallel to each other underground in trenches. The following minimum, wall to wall, separation must be provided: Stains plumbing fixtures and laundry - ANSWER-The source of water containing iron and manganese is usually groundwater. This water: Under registers the amount of water delivered - ANSWER-As a water meter becomes worn with use it tends to: Rotten eggs - ANSWER-Hydrogen sulfide gives off ___________ odor

Show more Read less
Institution
Water Distribution D1 And D2 Good
Course
Water distribution d1 and d2 good









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Water distribution d1 and d2 good
Course
Water distribution d1 and d2 good

Document information

Uploaded on
April 8, 2024
Number of pages
7
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Water distribution d1 and d2 good
Exam Questions and Answers 100%
Accurate

Wet tap - ANSWER-A connection made into a main that is full or under pressure is a

Cross connection - ANSWER-A connection between a safe and an unsafe water
supply is called a

Is available for use without causing shortages during dry periods - ANSWER-Safe
yield of a water source is the quantity of water which:

Rate of flow of water - ANSWER-A Venturi tube increases the velocity and
decreases the pressure as water flows through it. This type of tube is used to
measure the:

Underground strata of water - ANSWER-Aquifer is a type of

10 percent - ANSWER-In a well managed metered distribution system, unaccounted-
for-water should not exceed

35 psi - ANSWER-According to AWWA guidelines, during a fire,water pressure
should not drop below 20 psi. What is the AWWA recommended minimum water
pressure in a distribution system, under normal flow conditions, excluding fire flow?

Closed slowly to reduce surges - ANSWER-After using a hydrant, the hydrant should
be:

15-20 ft - ANSWER-For a centrifugal pump in good condition, the practical suction lift
is.

Acidic - ANSWER-PH reading of 5.0 indicates the water sample is

Ten drops per minute - ANSWER-When using a centrifugal pump, the packing
glands around the shaft should be checked daily, water leakage from the packing
gland should be approximately

Horizontal 10 ft, vertical 1 ft - ANSWER-Water and sewer line are installed parallel to
each other underground in trenches. The following minimum, wall to wall, separation
must be provided:

Stains plumbing fixtures and laundry - ANSWER-The source of water containing iron
and manganese is usually groundwater. This water:

, Under registers the amount of water delivered - ANSWER-As a water meter
becomes worn with use it tends to:

Rotten eggs - ANSWER-Hydrogen sulfide gives off ___________ odor

Calcium and magnesium - ANSWER-Hardness is caused by

Causes teeth to become mottled - ANSWER-Water containing excess fluoride

Meters - ANSWER-Devices used to measure water flow are called

Purple - ANSWER-The color of pipe carrying recycled water to irrigate a golf course

Contamination of the system by back siphonage - ANSWER-Fire fighting may cause
the low pressure in an area of a distribution system. The low pressure might lead to:

Iron - ANSWER-Red water problems are due primarily to:

0-14 - ANSWER-PH range is:

Flush the eyes with a lot of water for approximately 15 minutes - ANSWER-If your
eyes are exposed to chlorine, you should:

Take three repeat samples - one from the same location, one upstream and one
downstream - within 24 hours - ANSWER-The first time a bacteriological sample
report comes back marked unsafe, you should

1.0 - ANSWER-One PPM is equal to ___ mg/l

All of the above: Chemical processing plant, hospitals, wastewater treatment plant -
ANSWER-A backflow prevention device is required on the water service line which
serves

5 feet - ANSWER-Per OSHA regulations trench must be shored if it is ______ deep,
or deeper

All of the above:
incorrect installation, misjudgment of soil conditions, Heavy loads or failure to
consider change in weather - ANSWER-The shoring systems sometimes fail due to

Nutating disc meter - ANSWER-Which of the following meter is commonly installed
in a single family, residential, homes

No more than 12-inches above the floor - ANSWER-The outlet of a forced ventilation
system for a chlorinator room should be located:

Pressure-reducing - ANSWER-Which of the following valves should be used when it
becomes necessary to supply water at different pressure zones
R174,90
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Document also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
IMORA West Virginia University
Follow You need to be logged in order to follow users or courses
Sold
192
Member since
2 year
Number of followers
77
Documents
5079
Last sold
1 week ago

4,4

69 reviews

5
49
4
8
3
8
2
1
1
3

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions