Master Mechanical License EXAM Questions with Correct Answers 100% || Graded A+ (2024)!!!
A permit shall become invalid if NOT used within how many days of issue - 180 Days All of the following info. is required to be on an electric comfort appliance cable EXCEPT - manufactures' date code The room or the space where a boiler will be installed shall have a min. of how many times the volume of the boiler - 16 The volume of a room compared to the volume of a furnace to be installed is based on what max. ceiling height - 8 ft A fuel burning appliance is located in a private garage & is protected from motor vehicle impact. The appliance shall have its ignition sources installed by what min. distance above the floor? - 1 1/2ft When more than 1 heating, cooling, ventilating system is installed on a roof of a building, each system shall be... - permanently identified by the area or space served by the equipment What min. work space is required in front of a warm air furnace in an attic? - 30X30 What are the requirements to install a warm air furnace in an attic? -