THE NATIONAL ELECTRICAL CODE 9TH
EDITION BY CHARLES R. MILLER CHAPTER 1-
19 FULL MANUAL WITH VERIFIED SOLUTIONS
,2 | P ,1a ,gIntroduction
Unit e ,to ,the ,National ,Electrical , Code ,Unit ,2 ,Definitions
1. The ,National ,Fire ,Protection ,Association ,has ,acted ,as ,sponsor ,of ,the ,National ,Electrical
Code ,since ,
, .
1911 ,(Pg.2)
2. Informative ,Annex , provides ,a ,list ,of ,product ,safety ,standards ,used ,for ,product ,listing
,where ,that ,listing ,is , required ,by ,the ,NEC.
Informative ,Annex ,A ,(NEC ,70-710)
3. Which ,chapters ,in ,the ,NEC ,apply ,generally ,to ,all ,installations?
Chapter ,1 ,through ,4 ,apply ,to ,all ,electrical ,installations ,(Pg.5)
4. Every ,three ,years, ,the ,National ,Electrical ,code ,is ,revised, ,but ,the ,Code ,has ,only ,been ,on ,a
three-year ,cycle ,since , , , .
,
1975 ,(Pg.2)
5. The ,purpose ,of ,the ,National ,Electrical ,Code ,is ,the ,practical ,safeguarding ,of
form ,hazards ,arising ,from ,the ,use ,of ,electricity.
Persons ,and ,Property ,(Pg.2)
6. The ,original ,Code ,document ,was ,developed ,in , as ,a ,result ,of ,the ,united ,efforts ,of
,various ,insurance, , electrical, ,architectural, ,and ,allied ,interests.
1897 ,(Pg.2)
7. Informative ,annexes ,are ,not ,part ,of ,the ,requirements ,of ,the ,NEC ,but ,are ,included ,for
only.
Informational ,Notes ,(Pg.5)
8. What ,city ,was ,home ,to ,the ,first ,central-station ,electric ,generating ,plant ,developed ,by
Thomas ,A. ,Edison?
,
New ,York ,City ,(Pg. ,2)
,3|Page
9. Chapter , , consists ,of ,tables ,that ,are ,applicable ,as ,referenced.
9 ,(Pg.5)
10. In ,the ,NEC, ,UL ,is ,the ,abbreviation ,for , .
Underwriters ,Laboratories, ,Inc. ,(Pg.7)
11. Listed ,or ,labeled ,equipment ,shall ,be ,installed ,and ,used ,in ,accordance ,with ,any
included ,in ,the ,listing ,or ,labeling.
Instructions ,(Pg. ,6) ,(NEC ,110.3 ,(B)).
Unit ,2
1. An , branch ,circuit ,supplies ,two ,or ,more ,receptacles ,or ,outlets ,for ,lighting ,and
,appliances.
General ,Purpose ,(Pg. ,16)
2. is ,the ,largest ,amount ,of ,current ,capable ,of ,being ,delivered ,at ,a ,point ,on ,the ,electrical
system ,during ,a ,shout-circuit ,condition.
,
Available ,fault ,current ,(Pg.20)
3. An , branch ,circuit ,consists ,of ,two ,or ,more ,ungrounded ,conductors ,having ,a
,potential ,difference ,between ,them, ,and ,a ,grounded ,conductor ,having ,equal ,potential
,difference ,between ,it ,and ,each ,ungrounded ,conductor ,of ,the ,circuit ,and ,that ,is ,connected
,to ,the ,neutral ,or ,grounded ,conductor ,of ,the ,system.
Multiwire ,(Pg.16)
4. An ,intermittent ,operation ,in ,which ,load ,conditions ,are ,regularly ,recurrent ,is ,the ,definition
of , .
,
Periodic ,Duty ,(NEC ,70-34)
5. The , is ,the ,connection ,between ,the ,grounded-circuit ,conductor ,and ,the ,equipment
,grounding ,conductor ,at ,the , service.
Main ,bonding ,jumper ,(Pg.14)
, 4|Page
6. An , is ,used ,to ,connect ,the ,system ,grounded ,conductor ,or ,the ,equipment ,to ,a
grounding ,electrode ,or ,to ,a ,point ,on ,the ,grounding ,electrode ,system.
,
Grounding ,electrode ,conductor ,(Pg. ,22)
7. Rainproof, ,raintight, ,or ,watertight ,equipment ,can ,fulfill ,the ,requirements ,for , , where
,varying ,weather ,conditions ,other ,than ,wetness, ,such ,as ,snow, ,ice, ,dust, ,or ,temperature
,extremes, ,are ,not ,a , factor.
Weatherproof ,(NEC ,70-41)
8. An , is ,an ,intentionally ,constructed, ,low-impedance ,electrically ,conductive ,path
,designed ,and ,intended ,to ,carry ,current ,underground-fault ,condition ,from ,the ,point ,of ,a
,ground , fault ,on ,a ,wiring ,system ,to ,the ,electrical , supply ,source ,and ,that ,facilitates ,the
,operation ,of ,the ,overcurrent ,protective ,device ,or ,ground-fault ,detectors.
Effective ,Ground-Fault ,Current ,Path ,(Pg. ,19)
9. An , is ,a ,manually ,operated ,device ,used ,in ,conjunction ,with ,a ,transfer ,switch ,to
,provide ,a , means ,directly ,connecting ,load ,conductors ,to ,a ,power , source ,and ,of
,disconnecting ,the ,transfer , switch.
Bypass ,Isolation ,Switch ,(NEC ,70-40) ,(Definition ,is ,updated ,and ,different ,in ,NEC ,2020)
10. A ,type ,of ,surface, ,flush, ,or ,freestanding ,raceway, ,designed ,to ,hold ,conductors ,and
,receptacles, ,assembled ,in ,the , field ,or ,at ,the , factory ,is ,called ,a
.
Multioutlet ,assembly ,(Pg. ,25)
11. A ,raceway ,encased ,in ,4 ,in. ,(102 ,mm) ,of ,concrete ,on ,the ,ground ,floor ,(in ,direct ,contact
,with ,the ,earth) ,shall ,be , considered ,a(n) , location.
Wet ,(NEC ,70-38)
12. A ,(n) , may ,consist ,of ,one ,or ,more ,sensing ,elements ,integral ,with ,the ,motor-compressor
and ,an ,external ,control ,device.
,
Thermal ,Protector ,(NEC ,70-41)