100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

MRI PatIent CaRe & MRI Safety (aRMRIt) exaM neweSt 2025/2026 wIth CoMPlete QueStIonS and CoRReCt anSweRS |alReady GRaded a+||BRand new VeRSIon!

Rating
-
Sold
-
Pages
10
Grade
A+
Uploaded on
19-12-2025
Written in
2025/2026

MRI PatIent CaRe & MRI Safety (aRMRIt) exaM neweSt 2025/2026 wIth CoMPlete QueStIonS and CoRReCt anSweRS |alReady GRaded a+||BRand new VeRSIon!

Institution
MRI PatIent CaRe & MRI Safety
Course
MRI PatIent CaRe & MRI Safety









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
MRI PatIent CaRe & MRI Safety
Course
MRI PatIent CaRe & MRI Safety

Document information

Uploaded on
December 19, 2025
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

MRI PatIent CaRe & MRI Safety (aRMRIt) exaM neweSt 2025/2026
wIth CoMPlete QueStIonS and CoRReCt anSweRS |alReady
GRaded a+||BRand new VeRSIon!




Maintaining an ambient room temperature between 65-75 degrees F, a relative
humidity of 50-70%, and adequate air flow in the MR imaging room is recommended
to: - CoRReCt anSweR-make patients more tolerant of the radio frequency heating
effects



The FDA defines the specific absorption rate to be below the level of concern at: -
CoRReCt anSweR-less than or equal to 4 W/kg averaged over the body



If the parameters selected for an imaging sequence will expose the patient to
specific absorption rate levels in excess of the FDA defined level of no concern, they
should never be employed on patients who are: - CoRReCt anSweR-febrile



The FDA safe level for exposure to radio frequency radiation during an MR procedure
is defined by restricting the specific absorption rate levels. Specific absorption rate
level restrictions are imposed to control the risk of: - CoRReCt anSweR-systemic and /
or local thermal injury

Studies have demonstrated that persons with suspected intraocular metallic bodies
must be screened prior to entering the static magnetic field. This can be adequately
accomplished by obtaining: - CoRReCt anSweR-plain film x-rays of the orbits



Orbital screening for suspected intraocular metallic bodies should be done prior to
admitting patients and personnel into an MR system: - CoRReCt anSweR-at or above
0.01 Tesla strength

, Patients with tattooed eyeliner and / or eye makeup containing ferrous pigment
should be screened and advised of what possible complication of MR imaging? -
CoRReCt anSweR-transient skin irritation or cutaneous swelling of the eyes and
surrounding tissues



Pregnant MR technologists should be restricted from entry into the electromagnetic
fields of the MR scanner. (True or False) - CoRReCt anSweR-false




The FDA defines the specific absorption rate to be at the level of concern when
exposure to the radio frequency energy produces a core temperature increase in the
body of: - CoRReCt anSweR-1.0 degree C



Acceptable safe levels for exposure of persons with cardiac pacemakers and
defibrillators to magnetic fields should be enforced at the ________ gauss perimeter in
the magnetic fringe field. - CoRReCt anSweR-5.0



Patients with Swanz Ganz catheters should not undergo MR procedures because: -
CoRReCt anSweR-eddy current inductive heating may melt the catheter



What technique change could be employed to reduce radio frequency power
deposition and circumvent the specific absorption rate limitations? - CoRReCt
anSweR-shoulder



Specific absorption rate limitation problems are more likely to be experienced using
which transmitter coil: - CoRReCt anSweR-body



If electronic decoupling of the coils is not available on an MR system, the position of
the receiver coil to the transmitter must be true to an orthogonal plane (usually
horizontal) of the magnet to avoid: - CoRReCt anSweR-possible damage to the coil

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DoctorDee Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
2 year
Number of followers
6
Documents
2117
Last sold
2 weeks ago
Hi wayne1111

3.0

1 reviews

5
0
4
0
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions