The lowest part of a fuel ground furnace shall have now not less than a __________ -inch
clearance from grade stage.
6 (G2437.4)
Where gasoline piping is placed within a framing member and is much less than _________
inches from the framing member face to which wall, ceiling or ground membranes may be
connected, the piping shall be blanketed with the aid of guard plates.
1 half (G2415.7.2)
For gasoline appliance installations using the two-permanent-openings technique for outdoor
combustion air, one establishing commencing inside _____ inches of teh pinnacle and one
setting out inside _______ inches of the lowest of the enclosure, will be supplied.
12, 12 (G2407.6.1)
Vent piping on oil tanks will be no longer smaller than _______ -inch pipe.
1 1/four (M2203.4)
Components of a solar thermal power machine that might be subjected to a vacuum all
through operation or shutdown will be designed to resist such a vacuum or will be included
with _____ _____ _____.
Vacuum remedy valves (M2301.2.Four)
BTU is the abbreviation for _____ _____ ____, which is the amount of heat required to
elevate the temperature of one pound of water 1 F.
British Thermal Unit (G2403)
The maximum quantity of gas oil stored above ground or inside a building will be ______
gallons.
660 (M2201.2)
Attics containing home equipment shall be supplied with a gap and a clear and unobstructed
passageway big enough to allow removal of the biggest equipment, however not much less
than _____ inches high and _____ inches wide and not more than _______ ft lengthy.
30
22
,20
(M1305.1.2)
For mechanical machine installations in flood risk areas, _____ _____ openings shall be
positioned at or above the required elevation
combustion air
(M1701.2)
Attics containing mechanical appliances shall be supplied with an opening and a clear and
unobstructed passageway large enough to permit elimination of the _____ equipment.
Largest
(M1305.1.2)
Where a space for a _____________________ _____________________ is furnished, an
exhaust duct gadget shall be established.
Clothes dryer
M1502.Four.8
Gas appliance shutoff valves shall be positioned inside the same room as the appliance and
not further than _____________________ feet from the appliance.
6
(G2420.5.1)
Manually operated vent ________ shall not be mounted except in connectors or chimneys
serving strong gasoline-burning home equipment.
Dampers
M1802.2.1
Boiler strain comfort valve discharge shall be piped to drains by gravity to within ________
inches of the ground or to an open receptor.
18
M2002.Four
, Gas vents that are over 12 inches in size or are positioned less than 8 ft from a vertical wall
or similar obstruction shall terminate no longer less than _______ feet above the highest
factor where they skip via the roof.
2
G2427.6.Four, Item 2
Sauna warmers shall be equipped with a thermostat that will restriction room temperature to
now not more than ___ tiers F
194
M1902.Four
Fuel-gasoline-fired garments dryer exhaust duct length will be _____ inches nominal in
diameter
4
G2439.7.1
A Type-B-W gas vent shall terminate not much less than _______ feet in vertical top above
the lowest of the wall furnace.
12
G2427.6.Five
Fuel gas equipment connectors shall have an universal duration now not to exceed _____
feet.
6
G2422.1.2.1
Transition ducts used to attach the dryer to the exhaust duct gadget will be .. No longer extra
than ___________ feet in period
eight
G2439.7.Three
A four-inch radius mitered forty five-degree elbow dryer exhaust duct fitting shall reduce the
most 35-foot duration of a dryer duct by ______ ft _____ inches.
2
6