Restrictive
Where, in any precise case, specific sections of this code specify special substances,
methods of production or other requirements, the most_________shall govern.
Section R102.1
minimal
The reason of this code is to establish ________ necessities to safeguard the public
protection, health and wellknown welfare.
Section R101.Three
IRC
Where the volume of the reference to a referenced code or trendy includes challenge matter
that is in the scope of the IRC, the provisions of the ________ shall take precedence.
Section R102.4.2
pleasant rationale
An opportunity cloth or approach will be accredited in which the proposed design is _______
and complies with _______of the provisions of the IRC.
Section R104.11
two hundred sq.Feet
Other than typhoon shelters, a allow is not required for one story detached accent systems,
furnished that the ground place does no longer exceed _______ square feet
Section R a hundred and five.2
overall performance
Compliance with the unique ________ -primarily based provisions of the International Codes
will be an opportunity to the precise necessities of the IRC
Section R104.Eleven
7 toes
Fences now not over_______ feet excessive do now not require permits
Section R105.2
required
,A permit isn't always required for the alternative of branch circuit overcurrent
devices(breakers) of the ________ capability inside the identical place (within a panel)
Section R105.2
two hundred sq.Ft 30in
Decks not exceeding ______ square toes in place, that are not more than _______ inches
above grade at any factor, are not attached to a residing, do no longer require a permit.
Section R105.2
next working (to the building reliable)
Where equipment replacements and repairs ought to be finished in an emergency state of
affairs, the permit application shall be submitted within the _______ _________ commercial
enterprise day.
Section R105.2.1
180 (a hundred and eighty days additionally applies to extensions)
An utility for a permit for any proposed paintings shall be deemed to had been abandoned
___________days after the date of filing.
Section R105.3.2
authorized
Before issuing a allow, the constructing reliable is __________ to observe or purpose to be
tested homes, systems and web sites for which an utility has been filed.
Section R105.Nine
REVIEWED FOR CODE COMPLIANCE
Where the constructing legit troubles a permit, the development files will be accepted in
writing or by using a stamp that states ___________ _________ _________ ___________.
Section R106.3.1
complete occupancy
Final inspection shall be made after the accepted work is ____________ and prior to
____________.
Section R109.1.6
very last
If placed in a flood risk area, the documentation of elevations required in Section R322.1.10
shall be submitted to the building official prior to the ______________ inspection
Section R109.1.6.1
,Access (to)
That which enables a tool, an equipment or equipment to be reached by way of equipped
access or by means of a way that first calls for the elimination or motion of a panel, door or
similar obstruction.
Section R202
Attic, Habitable
A completed or unfinished habitable space inside a attic
Section R202
one hundred twenty*F
Hot water is water at a temperature extra than ________*F
Section R202
load-bearing
A wall helping any vertical load similarly to its own weight is a ___________-_____________
wall
Section R202
30 kilos in line with rectangular foot
What is the minimum uniformly allotted live load for habitable attics and attics served with
constant stairs?
Table R301.Five
7/16in 8ft
Wood structural panels with a thickness of no longer much less than __________ inch and a
span of now not extra than _________ ft will be permitted for opening safety in windborne
particles regions.
Section R301.2.1.2
D0, D1 and D2
The seismic provisions of the IRC follow to detached one- and family dwellings in Seismic
Design Categories _______________.
Section R301.2.2
three ft
For dwellings with fireplace sprinkler structures, exterior walls with a fire separation distance
less than __________ toes shall have not less than a 1 hour hearth-resistance score with
publicity from the outdoor.
Table R302.1.(2)
, 2 hr hearth-resistance rated
Where an automated sprinkler machine in accordance with Section P2904 isn't always
furnished, the not unusual wall among townhouse units will be not much less than a
_________-hour_________-__________-__________wall meeting.
Section R302.2.2
four ft four ft
For townhouse separation, a parapet is not required where the roof sheathing is
hearth-retardant-handled wooden for a distance of ___________feet on each aspect of the
wall or partitions and there aren't any penetrations within the roof within ________feet of the
not unusual partitions.
Section R 302.2.4
1 hr
Dwelling devices in two-own family dwellings will be separated from each other with the aid
of wall and ground assemblies having no longer much less than a ___________- hour
fireplace-resistance score
Section R302.Three
napping functions
Opening from a personal storage directly right into a room used for ___________
_________ shall not be accredited.
Section R302.5.1
self-latching automated-final tool
Doors between the storage and residence will be ___________ ____________ and shall be
prepared with a self-last or ___________-__________ ____________.
Section R302.5.1
1/2in
Garages will be separated from residences and attics via not much less than
____________-inch gypsum board or equivalent implemented to the garage aspect.
Table R302.6
half of
Enclosed space beneath stairs this is accessed by using a door or get entry to panel shall
have partitions, underneath-stairs floor and any soffits blanketed on the enclosed aspect
with__________- inch gypsum board.
Section R302.7