Minimal sedation 3.3.66.4 page 22 Answers A drug induced state during
which patients respond normally to verbal commands although cognitive
functions and coordination may be impaired, ventilatory and cardiovascular
functions are unaffected.
Category two space 3.3.136.2 page 24 Answers Space in which failure of
equipment or system is likely to cause MINOR injury to patient, staff, or a
visitor.
Category three space 3.3.136.3 page 24 Answers Space in which the failure
of equipment or a system is NOT LIKELY to cause injury to patient, staff, or
visitor but can cause discomfort.
Risk category 2 3.3.158.2 page 25 Answers Activities, systems or
equipment who is a failure is likely to cause MINOR injury to patient, staff, or
visitors
Risk category three3.3.1 58.3 page 26 Answers Activities, systems, or
equipment whose failure is NOT LIKELY to cause injury to patient, staff, or
visitors but can cause discomfort.
Primary supply 3.3.171.2 page 26 Answers The portion of the central supply
system that is default system for the piping system.
Reserve supply 3.3.171.3 page 26 Answers Where provided, the portion of
the central supply system that will supply the piping system win the primary
and secondary supplies are exhausted or are not operative.
Waste anesthetic gas disposal 3.3.181 page 26 Answers The process of
capturing in carrying our way gas is vented from the patient's breathing
circuit during normal operation of gas anesthetic or analgesia equipment.
, Category 2. 4.1.2 page 27 Answers Activities, systems, or equipment who is
failure is likely to cause MINOR injury of patience, staff or visitors Shelby
design to meet category choose requirement, as details in this code.
Authority having jurisdiction 5.1.1.4 page 28 Answers And existing system
that is not in strict compliance with the provisions of this coach I'll be
permitted to be continued and use as long as the ______________________has
determined that such use does not constitute just think hazard to life
2 inches, 360°, 5.1.3.1.3 page 28 Answers Liquid containers shall have
additional product identification visible from all directions with a minimum of
________high letters such as a ___________wraparound tape for medical liquid
containers.
125°, 20°, 5.1.3.2.12 and 13 page 29 Answers Cylinders in use and in storage
shall be prevented from reaching temperatures in excess of ________and shall
never be lower than _______.
Manifold for gas cylinders, manifold for cryo-genic liquid containers, in
building emergency reserves, instrument air stand by headers, individual
components on the actual inside of concentrator sources 5.1.3.3.1.2 page 29
Answers What are the following systems shall be permitted to be located
together in the same INDOOR enclosure?
Medical errors central supply compressor supply stores, medical surgical
vacuum central supply stores, waste anesthetic gas disposal supply
sources..5.1.3.3.1.3 page 29 Answers What are the following CENTRAL
SUPPLY systems shall be permitted to be located together in the same
room?
200 ft.² 5.1.3.3.2 page 29 Answers During the design and construction I have
a central supply system and the storage of positive pressure Is located
outdoors and is greater than _________, they shall be provided with a minimum
of two entry/exit.
Motor driven machinery 5.1.3.3.4.2 page 30 Answers Cylinders, whether full
or empty, shall not be stored in enclosure containing ___________, with the
exception of cylinders intended for instrument air reserve headers, which
shall be permitted to be placed in the same location containing an
instrument air compressor when it has motor driven machinery located
within the room. All the cylinders intended for the instrument air reserve