Electrical Apprenticeship Year 1 Exam with Accurate Solutions

Institution
Electrical Apprentice
Course
Electrical apprentice









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Electrical apprentice
Course
Electrical apprentice

Document information

Uploaded on
November 20, 2025
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Electrical Apprenticeship Year 1 Exam
with Accurate Solutions

Telecommunications and electronic equipment - ANSWER-Category 1 meters are rated
for _______________.

residential current - ANSWER-Category 2 meters are rated for _______________.

industrial purposes - ANSWER-Category 3 meters are rated for _______________.

three-phase utility and outdoor conductors - ANSWER-Category 4 meters are rated for
_______________.


The length of a straight pull for multiple raceways must be at least ____ times the trade
size (metric designator) of the largest single raceway. - ANSWER-eight

Conduit provisions - ANSWER-chapter 9 table 4

Raceway Provisions - ANSWER-Table 348.22

ENT shall be secured every - ANSWER-3 feet (362.30 A)

Contact of dissimilar metals (except for the combination of aluminum and steel) should
be avoided wherever possible to lessen the potential for ____. - ANSWER-galvanic
action

Grounding conductors are required for circuits over ____ amperes. (When using
Flexible Metal Conduit) - ANSWER-20

An individual branch circuit ____. - ANSWER-supplies only one utilization equipment

As required by 110.26, working space around electrical equipment is primarily
concerned with ____. - ANSWER-service and escape due to emergency

A 12 AWG copper conductor requires ____ free space within a device box. - ANSWER-
2,25 in. cubed

Each yoke or strap containing one or more devices or equipment in a device box counts
as ____ conductor(s). - ANSWER-two

, Concealed means ____ by the building structure or finish. - ANSWER-rendered
inaccessible

For a one-family dwelling, at least one receptacle outlet accessible while standing at
grade level and located not more than _____ft. above grade shall be installed at the
front and back of the dwelling. - ANSWER-6.5

At least one 125-volt, single phase, 15- or 20-ampere-rated receptacle outlet shall be
installed within _______ ft of the electrical service equipment in a multifamily dwelling. -
ANSWER-25

Minimum clothes dryer demand load - ANSWER-5000 watts 220.54

Load Calculations - ANSWER-idk, mang

Service drop conductors shall have a vertical clearance of not less than
_____________ feet above the roof surface - ANSWER-8

Equipment grounding conductor provisions - ANSWER-Table 250.122 and 250.102

What is the service demand load in kW for an apartment complex containing ten each of
the following. 15 kW ranges, 13 kW ranges, 11 kW ranges, and 9 kW ranges. the
service is single phase. - ANSWER-Table 220.55
First find the average kW using 12 kW for any range rated less than 12 kW
(10 x 15) + (10 x 13) + (10 x 12) + (10 x 12) = 150 + 130 + 120 + 120 = 520 kW
[Note that we used 12 kW for the 11kW and the 9 kW]
520 kW / 40 ranges = 13 kW average range size.
Column C shows 15kw + 40 (number of ranges) = 55 kW
This 55kW must be increased by 5% for each kW above 12 the average size is.
55 kW x 1.05 = 57.75 kW demand load.

In_________________, remote, central, or automatic control of lighting shall be
permitted - ANSWER-hallways, staircases, and outdoor entrances

A grounded circuit conductor shall be permitted to ground non-current carrying metal
parts of equipment on the ______________ side of the ac service disconnecting means
- ANSWER-supply

Equipment grounding conductors, where installed, shall be increased in size
proportionately according to________________ - ANSWER-Circular mil area of the
ungrounded conductors

An intersystem bonding termination shall consist of a set of terminals with the capacity
for connection of not less than ________ intersystem bonding conductors. - ANSWER-3
$18.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
EXAMHAVEN

Get to know the seller

Seller avatar
EXAMHAVEN Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
3
Member since
1 year
Number of followers
1
Documents
1481
Last sold
1 month ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions