100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NFPA-99 CERTIFICATION REAL EXAM WITH 100% ANSWERS

Rating
-
Sold
-
Pages
21
Grade
A+
Uploaded on
20-11-2025
Written in
2025/2026

If nonmetallic flexible connectors is being used in a category 1 healthcare faculty to connect to the manifold to the gas distribution piping what is the maximum length permitted for the flexible connectors? A) 2.5 feet B) 5 feet C) They shall be no longer necessary D) the use of flexible connectors is not permitted. C) They shall be no longer necessary {5.1.10.11.6} **Under which of these conditions shall the instrument Air Reserve header cylinders be permitted to be stored with the instrument air compressor? A) the mechanical equipment room does not contain a boiler. B) the medical air compressors are in the same room. C) the only motor-driven machinery in the room is for instrument air equipment. D) the room is secured with lockable doors. C) The only motor-driven machinery in the room is for the instrument air equipment Riser valves are those valves located where? A) adjacent to the main riser downstream of any zone valve. B) anywhere in the lateral branches of the piping system. C) in the mainline adjacent to the base of the riser. D) in the riser adjacent to the mainline. D) In the riser adjacent to the main line {5.1.4.4}

Show more Read less
Institution
NFPA-99 CERTIFICATION
Course
NFPA-99 CERTIFICATION










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NFPA-99 CERTIFICATION
Course
NFPA-99 CERTIFICATION

Document information

Uploaded on
November 20, 2025
Number of pages
21
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NFPA-99 CERTIFICATION REAL
EXAM WITH 100% ANSWERS
2025-2026

If nonmetallic flexible connectors is being used in a
category 1 healthcare faculty to connect to the manifold to
the gas distribution piping what is the maximum length
permitted for the flexible connectors?
A) 2.5 feet
B) 5 feet
C) They shall be no longer necessary
D) the use of flexible connectors is not permitted.
C) They shall be no longer necessary {5.1.10.11.6}


**Under which of these conditions shall the instrument Air
Reserve header cylinders be permitted to be stored with
the instrument air compressor?
A) the mechanical equipment room does not contain a
boiler.
B) the medical air compressors are in the same room.
C) the only motor-driven machinery in the room is for
instrument air equipment.
D) the room is secured with lockable doors.
C) The only motor-driven machinery in the room is for the
instrument air equipment

,Riser valves are those valves located where?
A) adjacent to the main riser downstream of any zone
valve.
B) anywhere in the lateral branches of the piping system.
C) in the mainline adjacent to the base of the riser.
D) in the riser adjacent to the mainline.
D) In the riser adjacent to the main line {5.1.4.4}


When is the initial pressure test conducted by the
installer?
A) after blowdown of the distribution piping.
B) after installation of alarm sensors.
C) before blowdown of distribution piping.
D) before installation of station rough in assembly.
A) After blow-down of the distribution
piping.{5.1.12.2.3.2(1)}

**In those portions of systems intended to handle oxygen
at pressure greater than 350 psi the inter connecting hose
shall not contain what materials?
A) brass.
B) copper
C) polymeric
D) stainless steel
C) Polymeric

, The tool shown here allows the installer to mechanically
limit the makeup depth of the fitting to be brazed. Under
what condition is this method permitted for the
installation of medical gas piping?
A) only on final line connectors.
B) only on vacuum systems.
C) where only B cup 5 brazing rod is used
D) where the limited makeup depth is not less than
minimum cut depth her ANSI / ASME recommendations
D) Where the limited makeup depth is not less than
minimum cup depth current ANSI\ASME recommendation
{5.1.10.4.6.1}


What is the standard gauge pressure for nitrogen gas
service?
A) 15 - 30
B) 50 - 55
C) 162 185
D) it varies with system type.
C) 160 - 185psi {5.1.11}


What is a NFPA 99 requirement for labeling of pipes in
medical gas system?
A) color coding
B) fixed label width

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
docciel Walden University
View profile
Follow You need to be logged in order to follow users or courses
Sold
20
Member since
2 year
Number of followers
11
Documents
792
Last sold
2 weeks ago

5.0

2 reviews

5
2
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions