An indirect fired Appliance intended to supply heated air for
space Heating and other purposes but not intended for
© 2025 Assignment Expert
permanent installation [ANS:] Air heater
An electrical switch designed to prove that the proper draft has
been established by the power Venter or burner and allows the
Guru01 - Stuvia
burner to operate. It will de-energize the burner control circuit
preventing the burner from operating, if the power venter or
burner is not performing to satisfaction. [ANS:] Air pressure switch
A primary safety control that causes the flow of fuel to be shut off
upon a rise in fuel level or upon receiving excess Fuel, and which
operates before the Hazardous discharge of fuel can occur.
[ANS:] Anti flooding device
Appliances in which materials are heated or melted at
temperatures not exceeding 600°F (316°C) and if not larger than
100 cu ft (2.8 m3) not including any blower equipment and blower
compartment. [ANS:] Low heat industrial Appliance
Appliances operating at over 50 PSIG (345 kPa) pressure when
such Appliance is larger than 100 cu ft (2.8 m3) in size. Aswell as
other medium-heat appliances in accordance with recognized
good practice. [ANS:] Medium heat industrial appliance
, 2
For Expert help and assignment solutions, +254707240657
An industrial Appliance larger than 100 cu ft (2.8 m3) in size, and
other furnaces classified as high-heat appliances in accordance
with recognized good practice. [ANS:] High heat industrial
Appliance
A standard form issued for use in all jurisdictions throughout the
Commonwealth. [ANS:] Application permit/Certificate of
Completion
Unless otherwise indicated listed or approved by a nationally
recognized testing Laboratory [ANS:] Approved
© 2025 Assignment Expert
The State Fire Marshal or his designee [ANS:] Authority having
jurisdiction
Guru01 - Stuvia
A closed vessel in which water is heated, steam is generated,
steam is superheated, or any combination thereof, by the
application of heat from combustible fuels in a self-contained or
attached furnace [ANS:] Boiler
A boiler for generating steam at pressures in excess of 15 psi (103
kPa) or for heating water to a temperature in excess of 250° F
(121°C) or at a pressure in excess of 160 PSI (1103 kPa) [ANS:]
Boiler, High Pressure
A low pressure hot water boiler having a volume not exceeding
120 gal (454 L) or a heat input exceeding 200,000 BTU per hour
(58.6 kW) or an operating temperature exceeding 200° F (93°C)
that provides hot water to be used externally to itself [ANS:] Boiler
hot water supply
A boiler for generating steam at pressures not in excess of 15 PSIG
(103 kPa) or for Furnishing water at a temperature not in excess of
250° F (121°C) pressure's not in excess of 160 PSIG (1103 kPa) [ANS:]
Boiler, low pressure
For Expert help and assignment solutions, +254707240657
OIL BURNER LICENSE EXAM 2025/2026
BANK COMPLETE 300 QUESTIONS WITH
DETAILED VERIFIED ANSWERS (100%
CORRECT ANSWERS) /ALREADY GRADED
A+ Graded A+
An indirect fired Appliance intended to supply heated air for
space Heating and other purposes but not intended for
© 2025 Assignment Expert
permanent installation [ANS:] Air heater
An electrical switch designed to prove that the proper draft has
been established by the power Venter or burner and allows the
Guru01 - Stuvia
burner to operate. It will de-energize the burner control circuit
preventing the burner from operating, if the power venter or
burner is not performing to satisfaction. [ANS:] Air pressure switch
A primary safety control that causes the flow of fuel to be shut off
upon a rise in fuel level or upon receiving excess Fuel, and which
operates before the Hazardous discharge of fuel can occur.
[ANS:] Anti flooding device
Appliances in which materials are heated or melted at
temperatures not exceeding 600°F (316°C) and if not larger than
100 cu ft (2.8 m3) not including any blower equipment and blower
compartment. [ANS:] Low heat industrial Appliance
Appliances operating at over 50 PSIG (345 kPa) pressure when
such Appliance is larger than 100 cu ft (2.8 m3) in size. Aswell as
other medium-heat appliances in accordance with recognized
good practice. [ANS:] Medium heat industrial appliance
, 2
For Expert help and assignment solutions, +254707240657
An industrial Appliance larger than 100 cu ft (2.8 m3) in size, and
other furnaces classified as high-heat appliances in accordance
with recognized good practice. [ANS:] High heat industrial
Appliance
A standard form issued for use in all jurisdictions throughout the
Commonwealth. [ANS:] Application permit/Certificate of
Completion
Unless otherwise indicated listed or approved by a nationally
recognized testing Laboratory [ANS:] Approved
© 2025 Assignment Expert
The State Fire Marshal or his designee [ANS:] Authority having
jurisdiction
Guru01 - Stuvia
A closed vessel in which water is heated, steam is generated,
steam is superheated, or any combination thereof, by the
application of heat from combustible fuels in a self-contained or
attached furnace [ANS:] Boiler
A boiler for generating steam at pressures in excess of 15 psi (103
kPa) or for heating water to a temperature in excess of 250° F
(121°C) or at a pressure in excess of 160 PSI (1103 kPa) [ANS:]
Boiler, High Pressure
A low pressure hot water boiler having a volume not exceeding
120 gal (454 L) or a heat input exceeding 200,000 BTU per hour
(58.6 kW) or an operating temperature exceeding 200° F (93°C)
that provides hot water to be used externally to itself [ANS:] Boiler
hot water supply
A boiler for generating steam at pressures not in excess of 15 PSIG
(103 kPa) or for Furnishing water at a temperature not in excess of
250° F (121°C) pressure's not in excess of 160 PSIG (1103 kPa) [ANS:]
Boiler, low pressure