Which of the following factors affects a customer's level of comfort? a. Air movement b. Humidity c. Temperature d. All of the above - Correct Answer d (All of the above: air movement, humidity, temperature) A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value. a. ±10% b. +10% c. +15% d. +30% - Correct Answer c (+15%) The maximum sensible cooling capacity of a heat pump should be within ____% of the calculated sensible heat gain of a structure with a large heating load. a. ±10% b. +15% c. -25% d. +25% - Correct Answer d (+25%) The combined output of a heat pump and its auxiliary heat should not exceed the calculated heat loss of a home by more than ____%. a. 10% b. 15% c. 20% d. 25% - Correct Answer b (15%) What amount of auxiliary electric heat is needed when the output of a heat pump on a design day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh? a. 2.1 kWh b. 3.2 kWh c. 5.0 kWh d. 10.9 kWh Note: 3,413 Btu/kW - Correct Answer b (3.2 kWh) The three processes that transfer heat energy are conduction, convection, and ____. a. concentration b. radiation c. refraction d. static pressure - Correct Answer b (radiation) Heat transfer that occurs when substances of different temperatures are in contact with each other is called ____. a. concentration b. conduction c. convection d. radiation - Correct Answer b (conduction) What effect does raising the pressure in a sealed system have on refrigerant? a. It becomes more difficult to subcool the liquid refrigerant b. It becomes more difficult to superheat the refrigerant vapor c. The refrigerant's boiling point decreases d. The refrigerant's boiling point increases - Correct Answer d (The refrigerant's boiling point increases) What is the primary danger to people near an accidental refrigerant release or spill? a. Blurred vision caused by the refrigerant vapor coming in contact with the eyes b. Changes in weather patterns caused by global warming c. Damage to the food chain caused by decreased ozone levels in the stratosphere d. Suffocation caused by the heavier refrigerant displacing oxygen in the air - Correct Answer d (Suffocation caused by the heavier refrigerant displacing oxygen in the air) The maximum temperature at which refrigerant may be stored is ____°F when the container is no more than ____% full of liquid by volume. a. 120°F, 60% b. 125°F, 60% c. 125°F, 80% d. 135°F, 80% - Correct Answer c (125°F, 80%) Boiling of the refrigerant occurs in which system component? a. Compressor b. Condenser c. Evaporator d. Metering device - Correct Answer c (Evaporator) Why is superheat necessary in a system that utilizes hermetic compressors? a. It ensures that dry vapor reaches the compressor so that mechanical damage does not occur b. It increases system capacity c. It prevents liquid refrigerant from gassing the metering device d. Superheat is necessary only when open compressors are being used - Correct Answer a (It ensures that dry vapor reaches the compressor so that mechanical damage does not occur) When the heat load on an evaporator increases, what is the effect on the system? a. Suction pressure decreases and discharge pressure increases b. Suction pressure increases and discharge pressure decreases c. Suction pressure and discharge pressure both decrease d. Suction pressure and discharge pressure both increase - Correct Answer d (Suction pressure and discharge pressure both increase) What type of energy is transferred when work is done in the condenser? a. Latent heat energy b. Sensible heat energy c. Both latent and sensible heat energy d. Neither latent nor sensible heat energy - Correct Answer c (Both latent and sensible heat energy) What is the primary function performed by a thermal expansion valve? a. It maintains the correct superheat in the hot vapor leaving the compressor b. It maintains the correct superheat in the suction vapor leaving the evaporator c. It maintains the proper subcooling level in the liquid refrigerant d. It prevents flash vapor bubbles from developing in refrigerant entering the evaporator - Correct Answer b (It maintains the correct superheat in the suction vapor leaving the evaporator) Which component pumps refrigerant through the system and raises the vapor temperature? a. Accumulator b. Compressor c. Condenser d. Evaporator - Correct Answer b (Compressor) How are hermetic compressor motors cooled? a. With air drawn around the compressor shell by the condenser fan b. With water circulated through tubing wrapped around the compressor shell c. With suction vapor drawn from the evaporator d. With a combination of air and water - Correct Answer c (With suction vapor drawn from the evaporator) Heat pump compressors sometimes run hotter than compressors used in cooling-only units because heat pump compressors ____. a. exhibit low refrigerant density at low suction pressures during the heating cycle b. pump liquid refrigerant during the cooling cycle c. must prevent ice formation during the defrost cycle d. must heat indoor spaces in the winter - Correct Answer a (exhibit low refrigerant density at low suction) When is a crankcase heater most needed? a. Early in the morning during the cooling cycle b. When the compressor is operating in very cold winter weather c. When the compressor is operating in very humid conditions d. When the compressor is off - Correct Answer d (When the compressor is off) Work done on the refrigerant in the condenser is transferred as ____. a. latent heat b. sensible heat c. specific heat d. both sensible and latent heat - Correct Answer d (both sensible and latent heat) Why are more circuits needed in the outdoor coils used in heat pumps than in the condenser coils used in cooling-only units? a. To keep the pressure drop across the outdoor coil high b. To keep the pressure drop across the outdoor coil low c. To provide more subcooling during the cooling cycle d. To provide more subcooling during the heating cycle - Correct Answer b (To keep the pressure

Show more Read less
Institution
NATE Air Conditioning And Heat Pumps
Course
NATE Air Conditioning and Heat Pumps










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NATE Air Conditioning and Heat Pumps
Course
NATE Air Conditioning and Heat Pumps

Document information

Uploaded on
October 31, 2025
Number of pages
30
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NATE Exam: Air Conditioning and Heat
Pumps Questions Answered Correctly
Which of the following factors affects a customer's level of comfort?



a. Air movement

b. Humidity

c. Temperature

d. All of the above - Correct Answer d (All of the above: air movement, humidity, temperature)



A cooling load calculation estimates the sensible heat gain of a structure. The maximum
sensible capacity of a cooling-only system should be within ____% of this calculated value.



a. ±10%

b. +10%

c. +15%

d. +30% - Correct Answer c (+15%)



The maximum sensible cooling capacity of a heat pump should be within ____% of the
calculated sensible heat gain of a structure with a large heating load.



a. ±10%

b. +15%

c. -25%

d. +25% - Correct Answer d (+25%)



The combined output of a heat pump and its auxiliary heat should not exceed the calculated
heat loss of a home by more than ____%.

,a. 10%

b. 15%

c. 20%

d. 25% - Correct Answer b (15%)



What amount of auxiliary electric heat is needed when the output of a heat pump on a design
day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh?



a. 2.1 kWh

b. 3.2 kWh

c. 5.0 kWh

d. 10.9 kWh



Note: 3,413 Btu/kW - Correct Answer b (3.2 kWh)



The three processes that transfer heat energy are conduction, convection, and ____.



a. concentration

b. radiation

c. refraction

d. static pressure - Correct Answer b (radiation)



Heat transfer that occurs when substances of different temperatures are in contact with each
other is called ____.



a. concentration

, b. conduction

c. convection

d. radiation - Correct Answer b (conduction)



What effect does raising the pressure in a sealed system have on refrigerant?



a. It becomes more difficult to subcool the liquid refrigerant

b. It becomes more difficult to superheat the refrigerant vapor

c. The refrigerant's boiling point decreases

d. The refrigerant's boiling point increases - Correct Answer d (The refrigerant's boiling point
increases)



What is the primary danger to people near an accidental refrigerant release or spill?



a. Blurred vision caused by the refrigerant vapor coming in contact with the eyes

b. Changes in weather patterns caused by global warming

c. Damage to the food chain caused by decreased ozone levels in the stratosphere

d. Suffocation caused by the heavier refrigerant displacing oxygen in the air - Correct Answer d
(Suffocation caused by the heavier refrigerant displacing oxygen in the air)



The maximum temperature at which refrigerant may be stored is ____°F when the container is
no more than ____% full of liquid by volume.



a. 120°F, 60%

b. 125°F, 60%

c. 125°F, 80%

d. 135°F, 80% - Correct Answer c (125°F, 80%)

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lydiah247 West Virgina University
View profile
Follow You need to be logged in order to follow users or courses
Sold
29
Member since
2 year
Number of followers
10
Documents
2870
Last sold
4 weeks ago
SHINE

Welcome to my page- you are able to get revision questions,Summary notes and Exams that help you pass .

2.2

5 reviews

5
1
4
0
3
1
2
0
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions